1 / 30

Gas jet based diagnostics for beam monitoring

This overview discusses the use of gas jet-based diagnostics for monitoring high-intensity/energy beams, including techniques such as synchrotron radiation, ionization profile monitoring, beam-induced fluorescence, and gas sheet monitoring. It also highlights the challenges in separating radiation from the beam and achieving high resolution. The potential benefits of gas jet and beam-induced fluorescence for beam profiling are explored.

wallacel
Télécharger la présentation

Gas jet based diagnostics for beam monitoring

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gas jet based diagnostics for beam monitoring Carsten P. Welsch

  2. Overview

  3. Profile of High Intensity/EnergyBeams • Damage caused by the beam • Ideally: Non-invasive.

  4. Synchrotron Radiation • In the visible ? Problem: Resolution (LHC).

  5. Interferometry or Masking • Goal: Overcome diffraction limit. • Coronograph ? • DMD-based system ? Thanks to G. Trad, A. Jeff

  6. SOHO *Solar and Heliospheric Observatory

  7. Halo Monitoring: Core Masking (1) Aquire profile (2) Define core (4) Re-Measure (3) Generate mask J. Egberts, et al., JINST 5 P04010 (2010) H. Zhang, et al., Phys. Rev. STAB 15 (2012)

  8. From Synchrotron Light Sources • Fresnel zone plates • Compound refractive lens

  9. Challenges • Need to separate radiation from beam • Large bending radius = large distances (> 100 m) • Depth of field issues: ~ r/g • Requires undulator to produce (soft) X-rays

  10. Ionization Profile Monitor (IPM) • Souce: J. Egberts, CEA • Based on ionization of rest gas • Challenges • Required residual gas pressure • 1D beam profile ‚only‘

  11. Beam InducedFluorescence (BIF) • Measures light from rest gas, excited by beam • Challenges: • Very low cross sections • Isotropic light emission • Rest gas pressure requirements

  12. N2-fluorescent gas equally distributed Vacuum gauge Blackened walls Valve 150mm flange Ionbeam Viewport Lens, Image-Intensifier and CCD FireWire-Camera Fluorescence Monitor Principle • Gas molecules are excited by the beam and emit a photon when returning to the ground state. • Emission wavelength is determined by the gas species • The relaxation time is typically 10s or 100s of ns. P. Forck et al., Beam induced fluorescence profile monitor developments, Proc. HB2010

  13. Gas Sheet Monitor • Generate thin atom gas curtain, • Ionize atoms with primary particle beam, • Extract ions via electric field, • Monitor on MCP, P screen. Y. Hashimoto et al., Proc. Part. Acc. Conf., Chicago (2001)

  14. How to Generate the Jet ? Y. Hashimoto et al., Proc. Part. Acc. Conf., Chicago (2001)

  15. Experimental Data Y. Hashimoto et al., Proc. Part. Acc. Conf., Chicago (2001)

  16. Setup @ Cockcroft Institute ^^

  17. Zoom: Main chamber MCP Extraction electrodes Phosphor coated window e- gun

  18. Setup

  19. Ionization Cross Sections • Can be exotic, e.g. single ionization of helium by antiproton impact H. Knudsen, Hyperfine Interactions 109 (1997) 133–143 H. Knudsen, Journal of Physics:Conf. Series 194 (2009) 012040

  20. Results @ CI e- beam Residual gas signal Gas Jet Jet signal V. Tzoganis, et al., APL 104 204104 (2014) V. Tzoganis, et al., VACUUM (2015)

  21. Example Measurement 1 1.8 mm 7.2 mm X Y

  22. Example Measurement 2 0.4 mm 4.0 mm X Y

  23. Understanding the Jet • Simulations using the CST and WARP codes H. Zhang, et al., Phys. Rev. AB (2016), submitted

  24. External field and image broadening 200V -2200V

  25. Jet Studies • Apply 3D movable ion gauge to scan through jet Vertical scan – yields profile Identify Mach disk location H. Zhang, et al., Phys. Rev. AB (2016), submitted

  26. sCCD= 90 mm sMCP= 80 mm Jet thickness Resolution

  27. Benefit from Jet and BIF ! • Generate light in collision between gas jet and beam • Detect photons and measure profile • R&D challenges: • Monitor integration (location, cryostat,…) • Optimum location, e.g. do we have to measure inside the solenoid? • Gas condensation, extraction and choice of species,… • Achievable resolution of optics and anticipated signal levels • Weareoptimizingthisideatowards HLLHC applicationwith CERN and GSI. • 2 monitorsplannedfor 2017 and 2019.

  28. Mechanic Design (DRAFT) ① ③ ④ ⑤ ② ③ ⑥ ① ④ ① ③ Differential gauge ② ② ⑤ ③ ④ ④ ④

  29. Also considered: Gas Jet Wire ? • Similar idea to laser wire • Challenge mm focus Fresnel Zone Plate Preliminary

  30. Summary Thanks for your attention !