1 / 12

Assessment of U.S. Corps Aerators in the San Joaquin River for the Port of Stockton

Assessment of U.S. Corps Aerators in the San Joaquin River for the Port of Stockton. September 2004 Jones & Stokes Russ Brown, Tom Trexler, Megan Robinson. Goals/Objectives. Determine the current level of performance of both aerators

zizi
Télécharger la présentation

Assessment of U.S. Corps Aerators in the San Joaquin River for the Port of Stockton

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Assessment of U.S. Corps Aerators in the San Joaquin River for the Port of Stockton September 2004 Jones & Stokes Russ Brown, Tom Trexler, Megan Robinson

  2. Goals/Objectives • Determine the current level of performance of both aerators • Estimate the oxygen loads from the aerators and the oxygen transfer efficiency • Compare aerator performance to release of oxygen gas from jets and different aerator device (Biox Hose)

  3. View of Aerator Dock

  4. Measurement Efforts • Measurements in Front of North Jets while Operating Both Aerators • Measurements in Front of South Jets while using Oxygen Gas

  5. Measurements and Estimations • Measured Velocity and DO concentrations of upwelling and/or flow-away currents • Estimated flow-away or upwelling width and calculated flows • Estimated Oxygen Loads from upwelling or flow-away flows and DO pick-up (measured DO minus background DO)

  6. Operation of Both Aerators

  7. Operation of South Jets with Pure Oxygen Gas

  8. Both Aerators DO Pick-up of 0.78 mg/l (Back. DO = 3.2 mg/l) Total Flow-away Flow of 90 cfs Total Oxygen Supply Rate of 402 lbs/day (assuming 40 ft flow-away width) South Jets with Oxygen DO Pick-up of 2.19 mg/l (Back. DO = 2.9 mg/l) Avg. Upwelling Flow of 191 cfs Avg. Oxygen Supply Rate of 2270 lbs/day Oxygen Transfer Efficiency of 45% Summary