1 / 2

2050-2060-2070-Series-High-Pressure-Filter-Assemblies-FLTR-Purple-Engineering

Product Code: 2050/2060/2070 Series High Pressure Filter Assemblies<br>2050/2060/2070 Series High Pressure Filter Assemblies Features Ultiporu00ae III or Rigimeshu00ae stainless steel media. Flows to 75 lpm (20 gpm).

FLTR
Télécharger la présentation

2050-2060-2070-Series-High-Pressure-Filter-Assemblies-FLTR-Purple-Engineering

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 1 Data Sheet PM&E 2050/2060/2070-A 2050/2060/2070 Series High Pressure Filter Assemblies Features • Ultipor®III or Rigimesh®stainless steel media • Flows to 75 lpm (20 gpm) • Pressures: 2050 Series: 690 bar (10,000 psi) 2060 Series: 1034 bar (15,000 psi) 2070 Series: 1379 bar (20,000 psi) • Port sizes: 3/8″, to 3/4″ Notes and Specifications Maximum Working Pressure: 2050 series: 2060 series: 2070 series: Proof Pressure: 2050 series: 2060 series: 2070 series: Typical Burst Pressure: 2050 series: 2060 series: 2070 series: Temperature Range: 690 bar (10,000 psi) 1000 bar (14,500 psi) 1379 bar (20,000 psi) 1034 bar (15,000 psi) 1500 bar (21,750 psi) 2068 bar (30,000 psi) 2758 bar (40,000 psi) 3490 bar (50,750 psi) 5516 bar (80,000 psi) Nitrile seals: -43˚C to 107˚C (-45˚F to 225˚F) Fluorocarbon Seals: -29˚C to 120˚C (–20˚F to 250˚F) 60˚C (140˚F) maximum in HWCF or water glycol fluids with Ultipor III media 2050, 2060, and 2070 series filter housings 2070 Series Flow (lpm) 20 30 40 50 60 0 10 50 3.0 40 V06 V09 W12 V12 30 2.0 Filter Element Collapse Pressure: 9020 series: 20 bar (290 psid); 9021 series: 207 bar (3000 psid); 310 bar (4500 psid) with Rigimesh all stainless steel media (NK or NJ options) Stainless steel; titanium bowl (2070/71) Ultipor III: Inorganic fibers impreg- nated and bonded with epoxy resins; stainless steel hardware. Rigimesh: All stainless steel (no resin binders) 20 P (psid) P (bar) 1.0 10 0 0 0 Flow (gpm) 2 4 6 8 10 12 14 16 Materials of Construction: Element Construction: Element Pressure Drop Multiply actual flow rate times factor to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 lpm and per 1 gpm. Pressure Drop Information Figure 1. Housing pressure drop using fluid with 0.9 S.G. Housing pressure drop is directly proportional to specific gravity. 2050/2060 Series Flow (lpm) 20 30 40 9020 Series Filter Elements — bar/1000 lpm (psid/gpm) Length Code 4 8 KZ 34.61 (1.90) 17.49 (0.96) KP 14.94 (0.82) 7.47 (0.41) KN 9.84 (0.54) 4.92 (0.27) KS 6.38 (0.35) 3.28 (0.18) KT 3.83 (0.21) 2.00 (0.11) 0 10 50 60 70 50 3.0 40 9021 Series Filter Elements — bar/1000 lpm (psid/gpm) B06 V09 V09 V06 30 2.0 Length Code 4 8 DP 49.37 (2.71) 24.59 (1.35) DS/NK 36.54 (0.53) 17.24 (0.25) DT/NJ 12.39 (0.68) 6.19 (0.34) 20 Δ P (psid) Δ P (bar) 1.0 A, B A, B B B 08/12 , C, W , C, W 1 10 0 0 0 Flow (gpm) 2 4 6 8 10 12 14 16 18 20 For more information: WEB WEB: FLTR.com.au PHONE PHONE: (+61) 1300 62 4020 EMAIL EMAIL: info@FLTR.com.au SKYPE SKYPE: Purple.Engineering

  2. 2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 2 249.94 mm/9.84 in (R-length) 345.44 mm/13.60 in (S-length) 25.4 mm 1.00 in Dimensional Drawings ‘H’ Dim. Ref. 2X 10.31 mm Ø.406 in Visual indicator 22.10 mm .87 in 1.19 Hex. 101 mm 4 in Explosion proof indicator INLET OUTLET 95 mm 3.75 in 57.15 mm 2.25 in ‘H’ Dim. Ref. Element change 150 Ref. mm 5.9 Ref. in 104.8 mm 4.125 in 111.4 mm Ø4.385 in V12 port option only 92.20 mm 3.63 in Primary port location (2050/51 and 2060/61 only) Mounting dimensions same as other options. OUTLET OUTLET INLET 24.99 mm .984 in 30.23 mm 1.19 in OUTLET INLET 24.99 mm .984 in 69.85 mm 2.75 in Table 4: Filter Element Options Code Bx(c)≥ 1000 KZ 3 KP 5 KN 7 KS 12 KT 22 DP 5 DS 12 DT 15 NK 5 µm* NJ 10 µm* Table 5: Length Options Housing Element Length (in) Code Code R 4 S 8 Secondary port location (2050/51 and 2060/61 only) 4 X 3/8-16 UNC 2B .70 deep * Element Series 9020(Ultipor III) 9020 (Ultipor III) 9020 (Ultipor III) 9020 (Ultipor III) 9020 (Ultipor III) 9021 (Ultipor III) 9021 (Ultipor III) 9021 (Ultipor III) 9021 (Rigimesh) 9021 (Rigimesh) 27.99 mm 1.102 in Ordering Information Assembly P/N: H 20 Table 1 Table 2 Table 3 Ultipor Element P/N: HC F Table 2 Table 4 Table 5 Rigimesh Element P/N: HC 9021 E 4 8 T * Nominal length Table 4 Table 5 Table 6 Table 7 Table 8 Y923 Table 1 Table 1: Seal Options Code Seals H Nitrile Z Fluorocarbon Table 4 Table 5 Table 1 * 98% efficiency Table 2: Series Options Housing Code Description 50 Table 6: Bypass Valve Options Code Valve B 3.4 bar (50 psid ) J 10 bar (150 psid ) S 13.8 bar (200 psid ) W Non-bypass, 100 psid indicator N Non-bypass, 35 psid indicator Element Code Housing Series 2050, 2060, 2070 2051, 2061, 2071 2051, 2061, 2071 2051, 2061, 2071* 2051, 2061, 2071* 690 bar (10,000 psi) housing with 50 psi bypass valve 1000 bar (14,500 psi) housing with 50 psi bypass valve 1379 bar (20,000 psi) housing with 50 psi bypass valve 690 bar (10,000 psi) 1034 bar (15,000 psi) 1379 bar (20,000 psi) 9020 60 9020 70 9020 9021 9021 9021 51 61 71 * Note: 2071 series does not have indicator ports Table 7: Differential Pressure Indicator Options* Code Indicator W Explosion proof E SST visual 0 No indicator port B SST port plug ‘H’ Dim. 79 mm (3.1 in) 28 mm (1.1 in) N/A 3 mm (0.12 in) Table 3: Port Options Code Port A08 A12 B06 B08 B12 C08 C12 V06 V09 V12 W12 Series 2050/51, 2060/61 2050/51 2050/51, 2060/61 2050/51, 2060/61 2050/51 2050/51, 2060/61 2050/51 2050/51, 2060/61, 2070 2050/51, 2060/61, 2070 2050/51, 2060/61, 2070 2050/51 1/2″ SAE J514 straight thread 3/4″ SAE J514 straight thread 3/8″ NPT 1/2″ NPT *Notes: 1. Select 2 indicator option codes per housing 2. Enter indicator codes alphabetically; put “0” code after alpha code if applicable 3. 2070/71 series does not have indicator ports; enter “00” in part number 3/4″ NPT 1/2″ BSP ISO 228 threads 3/4″ BSP ISO 228 threads Table 8: Mounting Bracket Options Code Option 0 None 1 Mounting bracket kit 3/8″ medium pressure threaded 9/16″ medium pressure threaded 3/4″ medium pressure threaded 3/4″ weld sockets For more information: WEB WEB: FLTR.com.au PHONE PHONE: (+61) 1300 62 4020 EMAIL EMAIL: info@FLTR.com.au SKYPE SKYPE: Purple.Engineering