90 likes | 211 Vues
Chelmsford Amateur Radio Society Advanced Course (9) Safety. High Voltages. Anything over 30V can be dangerous! All exposed metal surfaces should be earthed Unless impractical, work should never be carried out on live equipment
E N D
High Voltages • Anything over 30V can be dangerous! • All exposed metal surfaces should be earthed • Unless impractical, work should never be carried out on live equipment • Valve equipment generally uses power supplies with potentials much higher than domestic mains voltage • Recommend Residual Current Devices (RCDs) on mains
Portable Operation • Operating /P can introduce new hazards: • Overhead lines • Poor electrical supplies • Trailing cables • Damp ground • Excessive field strengths • So survey first, check cable routes/protection (trip hazards), use correct fusing, and use RCD’s. • No live working!!!
Mobile Operation • Operating in vehicles and vessels can bring new hazards • Insecure equipment • Long flexible aerials • Accidental shorts to earth • Distracted driving • RF induction into vehicle/vessels control circuits • Secure equipment, check cable routing/protection, use correct fusing, use hands free equipment, pay attention to good radio housekeeping
RF Field Strengths • Must comply with National Radiological Protection Board (NRPB) Investigation Levels for exposure to RF radiation. • The lowest limit for electric field strength was 50V/m in the 14-146 MHz range • If the Investigation Level is exceeded the cause must be investigated and reduced to a desirable one. • Check the latest levels. They are published at: http://www.nrpb.org/press/information_sheets/amateur_radio.htm • Field Strength calculations are covered in the EMC Section
Lightning Protection • Thunderstorms carry heavy static charges! • The static charge can ionise the air to form a low resistance path to ground allowing a very high current to flow as a lightning strike • The resulting risk to life, domestic property and electronic equipment associated with a strike and/or build up of a static charge is very high. • Little can be done to protect against a direct strike. Good static discharge systems can prevent dangerous static build up on aerial systems. Disconnecting aerials reduces risk
Protective Multiple Earthing • PME systems are where the mains earth terminal is connected to the neutral of the electricity service at the consumers premises, and are usually identified with a warning label. • All metal pipes and fittings within the premises are connected to the PME bonding point. • Under severe fault conditions (such as a neutral break) PME systems have the potential to cause fatal electric shocks and/or fires in Amateur Radio Stations. • The RF Earth in an Amateurs station should be connected to the PME bonding point to maintain safety under fault conditions in accordance with the IEE Wiring Regs.
Summary • All exposed metals should be earthed. • No work on live equipment, be careful with valves. • Working /P can bring new hazards. • Mobile working can bring new hazards. • Compliance with NRPB RF exposure minimum Investigation Levels is essential. • Thunderstorms can be dangerous, take necessary precautions • PME: Amateur Radio equipment RF earths should be connected to the PME bonding point.