T otally I ntegrated P ower

T otally I ntegrated P ower. The Portfolio at a Glance. totally integrated power. The System Environment – an Integrated Offer. Integrated Solutions for Power Distribution from Medium Voltage to the Wall Outlet. 1 Medium-Voltage Switchgear 2 Transformers 3 Busbar Trunking Systems

LeeJohn
Télécharger la présentation

T otally I ntegrated P ower

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Totally Integrated Power The Portfolio at a Glance

  2. totally integrated power The System Environment – an Integrated Offer

  3. Integrated Solutions for Power Distribution from Medium Voltage to the Wall Outlet 1 Medium-Voltage Switchgear 2 Transformers 3 Busbar Trunking Systems 4 Low-Voltage Switchgear 5 Subdistribution Boards 6 Circuit-Breakers 7 Switch-Disconnectors/in-line 8 Low-Voltage Circuit Protection 9 Switches and Outlets 10 Energy Automation 11 Power Management 12 Medium-Voltage Circuit Protection 13 Building Management Systems 14 Building Automation 15 Drives Overview 15 14 TotalBuildingSolutions 11 11 12 13 9 8 8 7 6 Totally Integrated Automation 5 4 4 2 1 5 9 1 2 4 3 3

  4. 1 Medium-Voltage Switchgear • The main task of a medium-voltage switchgear station is safe and economical power distribution. Power utilities, industrial applications or power plants - every operator has different demands of medium-voltage switchgear depending on the process-specific requirements. • This includes a high degree of reliability, safety of operating personnel, and low space requirements. Other relevant requirements are, besides appropriate voltage levels, air- or gas-insulated switchgear, scaling according to independence from ambient conditions, maintenance-free design, compactness, guaranteed return of investment, profitability, service friendliness and flexibility. Medium-Voltage Switchgear

  5. SIMOPRIME Air-insulated, metal-enclosed, metal-clad medium voltage switchgear up to 24KV from SIEMENS

  6. 2 GEAFOL Transformers • Wherever distribution transformers must be prepared for an utmost degree of safety, especially in the immediate vicinity of people, GEAFOL transformers make the perfect solution, e.g. in high-rise buildings, hospitals, road and subway tunnels, offshore and mining facilities etc. • High degree of operating safety • Long service life • Rated for 50 kVA to 30 MVA with operating voltages of up to 36 kV • Low flammability, self-extinguishing, no toxic gas emission in case of fire • Long service life due to freedom from partial discharges up to twice the rated voltage • Vacuum-cast high-voltage winding • Very good electrical, mechanical and thermal properties • High level of environmental compatibility GEAFOL Transformers

  7. SIMARIS design Dimensioning Software • Easy, fast and safe planning • Networks in power distribution systems for industrial, commercial and institutional buildings can be calculated and dimensioned with a minimum of manual work involved. • Short-circuit calculation • Load flow calculation • Voltage drop calculation • Selectivity evaluation • Fast and technically safe selection of the right protection devices • Dimensioning in compliance with IEC standards Dimensioning Software

  8. 3 SIVACON 8PS Busbar Trunking Systems (1) • Safety plus: • High short-circuit strength and low fire load • Increased planning reliability • Greater profitability: • Low space requirements • Straightforward network configuration • Fast installation • Easy retrofitting in case of on-the-spot changes of locations and connected loads of equipment • Better integration: • Complete current range from 25 A to 6,300 A for craft shops, office buildings and production halls • Communication-capable components • Connection to SIVACON switchboards Busbar Trunking Systems

  9. 3 SIVACON 8PS Busbar Trunking Systems (2) – System Overview CD-K System BD2 System LX System • For the power supplyof lighting systems andsmall equipment inshopping centers, logisticwarehouses and buildings • of all kinds. • For power transmissionand distribution in office buildings and power transfer in all industrial areas. • For power transmissionand distribution of high currents in large buildings, radio stations, data centers,and for chip and semi- conductor production. Busbar Trunking Systems BD01 System LD System LR System • For the power supply ofelectric tools in workshops as well as for lighting systems. • For power distribution and • and transmission in trade fair buildings, the automotive industry, heavy industry and on ships. • For the transmission of large • energy quantities und harsh ambient conditions, for the supply of tunnels, or for networking building parts outdoors and for the power transmissionin the chemical industry.

  10. 3 SIVACON 8PS Busbar Trunking Systems (3) Busbar Trunking Systems

  11. 4 Low-Voltage Switchgear (6) • SIVACON 8PT • Integrated safety: Type test, arcing fault and earthquake tests as proof of safety and quality • High degree of flexibility for marine and offshore applications • High degree of flexibility and economic efficiency thanks to a great variety of combinations • Improved profitability - integrated solutions for low-voltage power distribution thanks to type-tested interfacing to busbar trunking systems • High system availability - full communication capability with PROFIBUS DP • High degree of flexibility thanks to local SIVACON Technology Partners around the globe • Mainly for technical infrastructure applications Low-Voltage Switchgear

  12. 4 Low-Voltage Switchgear (7) • SIVACON 8PT - technical data Low-Voltage Switchgear

  13. 5 ALPHA Distribution Boards (1): ALPHA 125 Universal • ALPHA wall-mounted distribution boards • Used as main and sub-distribution boards in institutional, commercial and industrial buildings • In DIN standard: ALPHA 160 , ALPHA 400, ALPHA 630 • In NF standard: ALPHA 125, ALPHA 630 • Distribution boards and their components are modularly designed • Well-matched systems solutions ranging from assembly kits to floor-mounted distribution boards • Boards available with sheet-steel or transparent doors ALPHA 400 DIN ALPHA 630 DIN Subdistribution Boards • For electricians and switchgear panel builders: ALPHA SELECT® software enables fast configurations of distribution boards and meter cabinets.

  14. 6 SENTRON Circuit-Breakers (1) • SENTRON 3VL molded-case circuit-breakers • High degree of flexibility thanks to modular design • Molded-case circuit-breakers for easy installation, retrofitting and extension • All-round compatible accessories • Greater system transparency owing to communication capability • Direct interfacing to PROFIBUS DP via Com10 module • Easy access to Ethernet/Internet using BDA Plus for remote diagnosis and parameterization • Full transparency with power management • Areas of application • As feeder or outgoing circuit-breaker in distribution systems • As switching and protective devices for motors, transformers and capacitors • As main switch and EMERGENCY STOP switch in connection with lockable, rotary operating mechanisms and terminal covers Our 3VL molded-case circuit-breaker is the universal solution: As components for distribution boards, the product series from 16 A to 1,600 A excels by its tremendous versatility and its space-saving, compact design. Matching releases are available as thermo-magnetic (16 A to 630 A) and electronic versions (63 A to 1,600 A) – and the whole product range is complemented by merely two design families of internal accessories.   Circuit-Breakers

  15. 6 SENTRON Circuit-Breakers (2) • SENTRON 3WL air circuit-breaker • High degree of flexibility thanks to modular design • Easy circuit-breaker retrofitting and extension on site • Very few components for a multitude of functions in any application • Greater system transparency owing to communication capability • Direct interfacing to PROFIBUS DP via Com15 module • Easy access to Ethernet/Internet using BDA Plus for remote diagnosis and parameterization • External processing of messages / measured values via CubicleBUS module • Full transparency with power management • Areas of application • Suitable as incoming-feeder, distribution, outgoing-feeder switch and tie breaker in electrical installations • To switch and protect motors, capacitors, generators, transformers, busbars and cables • Suitable for use as EMERGENCY OFF switch in combination with an EMERGENCY OFF mechanism ( DIN VDE 0113, IEC 60204-1) 3WL air circuit-breakers are extremely flexible. With just three different sizes, they cover a performance range from 630 A to 6,300 A. This makes them uncompli- cated for use in many applications - everywhere in the world. In addition to circuit-breakers which comply with IEC standard 60947-2, there are also models with UL 489 and UL 1066 approval. All models feature the same design, the same handling, and the same mechanical accessories. And the result: unique planning reliability and a host of application possibilities worldwide. Circuit-Breakers

  16. 7 SENTRON Switch-Disconnectors (1) • Our wide product range of SENTRON switch-disconnectors and their versatile accessories ensure reliable disconnection and switching under load, plus proven, top-performance protection against overload and short circuits. With or without fuse: SENTRON switch-disconnectors are easy to use and retrofit. • Proven technology a million times over – continuously developed to suit requirements that arise in practice • Be on the safe side with every application – from line protection to personal safety • Easy, practical and time-saving handling • Uncomplicated integration into general solution concepts for low-voltage power distribution Switch-disconnectors

  17. 8 BETA Low-Voltage Circuit Protection (1) • BETA protecting • Miniature circuit-breakers • For the protection of indoor plants, for industrial applications and as a main switch for the disconnection or safety isolation of systems. • According to the relevant IEC standards, devices hold a worldwide approval for power systems up to 250/440 V AC. • For special applications and for plant construction, miniature circuit-breakers may be equipped with add-on components, like auxiliary current switches, fault signal switches, shunt releases, undervoltage releases and RCD modules. • Residual-current-operated protective devices • RCCBs of type A (pulse-current sensitive) are normally used in Germany; type AC (AC-current sensitive) in South European countries, for example. • SIQUENCE, type B, AC/DC-sensitive RCCBs also detect smooth DC fault currents besides fault current types A - smooth DC currents as they would occur in networks with frequency converters for drives. • Super-resistant RCCB, preventing accidental disconnections by short-time delayed tripping of the RCCB. Short-time pulsating discharge currents often occur, when capacitors are switched in. Low-Voltage Circuit Protection

  18. 8 BETA Low-Voltage Circuit Protection (2) • BETA protecting • Low-voltage fuse systems • NEOZED, DIAZED and LV HRC fuse systems are mainly used in distribution systems and for plant construction. NEOZED and DIAZED fuse systems can be handled by technically unexperienced or uninstructed persons, they are also approved for household installations. LV HRC fuses are an important part of the switchgear in utilities companies. • In South Western Europe, cylindrical fuses are also used in such applications. • SITOR semiconductor protection fuses protect power semiconductor devices against the effects of short circuits, because their super-quick tripping characteristics respond much faster than conventional LV HRC fuses. Special design types provide for customized installation. • Lightning current and overvoltage protection • Lightning current arresters are categorized according to lightning protection zones (LPZ). They are used for device and system protection against overvoltages and high surge currents caused by direct or indirect strikes of lightning. Low-Voltage Circuit Protection

  19. 8 BETA Low-Voltage Circuit Protection (3) • BETA switching - switches • ON/OFF switches are used for switching lighting, motors, and other electrical equipment. ON/OFF switches with current ratings of 32 A to 125 A can be applied as switch-disconnectors in compliance with IEC/EN 60947-3. • Remote-control switches, switching relays and Insta contactors are standard equipment in electrical installations, they are preferably used in residential buildings. They are particularly suited for switching heating and lighting systems as well as motors. • Mechanical and digital timers, timers for stairwell lighting and timing relays are used for timing electrical functions in buildings and facilities, being the basis for energy saving. Low-Voltage Circuit Protection

  20. 9 DELTA Switches and Outlets (1) • Overview of the product range DELTA line* - the switch range to express your style by ultra-modern forms DELTA vita* - a host of variations for setting individual color accents DELTA style - the design series that combines elegance with modern look DELTA miro glass* - clear switchdesign with frames made of glass Switches and Outlets DELTA miro Color* - makes exclusive design a standard DELTA profil*- the switch range that communicates harmony in shape and color DELTA natur*- the switch range that couples a sleek design with fine woods DELTA miro Holz* - sets design accents with real wood * suitable for Siemens GAMMA instabus ®