1 / 23

A Comparison of Activated Carbons of Differing Physical Characteristics in Cigarette Filters

Introduction. Previous work compared the adsorption characteristics of a fixed weight of different granular additives when used in cigarette filters This methodology causes uncertainties when comparing additives of differing density as the volume occupied by the additives (and therefore smoke contact times) will differActivated carbons are available from different raw materials at different activity levels - higher activation give rise to higher adsorption capacities, yet lower densitiesIncre9440

MikeCarlo
Télécharger la présentation

A Comparison of Activated Carbons of Differing Physical Characteristics in Cigarette Filters

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. A Comparison of Activated Carbons of Differing Physical Characteristics in Cigarette Filters A D McCormack & M J Taylor Filtrona Technology Centre Jarrow, United Kingdom 25th September 2007

    3. Materials Tested Coconut-based carbons Two commercially available carbons - medium and high activities One ultra-low activity carbon prepared by a university carbon laboratory Coal-based carbons Three commercially available carbons - low, medium and high activities All samples were selected to the same particle size range (30/70 US mesh)

    4. Carbons Tested - Physical Analysis

    5. Carbons Tested - Porosimetry Data

    6. Filter Designs and Assembly Hand-assembled triple granular filters, ensuring that 100% granular fill of the cavity was obtained Two fixed weights - 60 mg and 100 mg carbon Two fixed cavity volumes - 3mm and 5mm length Carbons dried prior to filter assembly

    7. Test Filter

    8. Test Cigarettes

    9. Analytical Procedures Methodology Cigarette tested around 3-weeks after assembly Standard ISO Smoking - Vapour phase collected in gas sampling bag for analysis by GC-MS Compounds Measured Aldehydes Acetaldehyde, Acrolein, Propionaldehyde, Butyraldehyde and Crotonaldehyde Ketones - Acetone and Methyl Ethyl Ketone Hydrocarbons 1,3 Butadiene, Isoprene, Benzene and Toluene Cyanides Acrylonitrile

    10. Calculation of Compound Retention % Retention = (Control Cigarette Yield Test Cigarette Yield) x 100 Control Cigarette Yield

    11. Retention of Aldehydes - 60mg Weight

    12. Retention of Aldehydes - 100mg Weight

    13. Retention of Aldehydes - 3mm Cavity

    14. Retention of Aldehydes - 5mm Cavity

    15. Retention of Hydrocarbons - 60mg Weight

    16. Retention of Hydrocarbons - 100mg Weight

    17. Retention of Hydrocarbons - 3mm Cavity

    18. Retention of Hydrocarbons - 5mm Cavity

    19. Retention of Ketones and Acrylonitrile - 60 mg Weight

    20. Retention of Ketones and Acrylonitrile - 3mm Cavity

    21. Effect of Carbon Weight and Carbon Surface Area per Tip on VP Retention

    22. Conclusions - 1 As expected, the retention of all compounds in the Vapour Phase by a carbon filter increases as a function of increasing carbon weight, increasing carbon bed length and increasing carbon activity Very low activity carbon (non-commercial) gives very little Vapour Phase retention benefit Coconut and coal-based carbons of similar activity gave similar removal efficiency, with the exception of the more volatile compounds (e.g. acetaldehyde and 1,3-butadiene) for which coconut carbons gave greater retention The data is consistent with previous observations that carbon gives a significant reduction of a wide range of compounds in smoke, although there is some indication that lower activity carbons may be less selective towards certain compounds (e.g. Acrylonitrile)

    23. Conclusions - 2 Within a fixed volume, higher activity carbons do provide some higher retention capability, but the performance benefits are relatively small The Vapour Phase retention of many of these filters was very high and in such cases there would be little benefit in using greater carbon quantities or higher carbon activities. It would be interesting to carry out similar experiments at lower carbon weights and for different cigarette filter types More work is required to explore the relationships between fundamental carbon properties and their effect on cigarette filter performance

    24. Thank you for your attention

More Related