1 / 51

Audio and Acoustic Analyzer

Audio and Acoustic Analyzer. Introducing the new flagship of the handheld EXEL line. V1.001, Sep. 09. Audio and Acoustic Analyzer. Sound Level Meter Real Time Analyzer. Audio and Acoustic Analyzer. Sound Level Meter Real Time Analyzer Acoustic Analyzer. Audio and Acoustic Analyzer.

Olivia
Télécharger la présentation

Audio and Acoustic Analyzer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Audio and Acoustic Analyzer Introducing the new flagship of the handheld EXEL line. V1.001, Sep. 09

  2. Audio and Acoustic Analyzer • Sound Level MeterReal Time Analyzer

  3. Audio and Acoustic Analyzer • Sound Level MeterReal Time Analyzer • Acoustic Analyzer

  4. Audio and Acoustic Analyzer • Sound Level MeterReal Time Analyzer • Acoustic Analyzer • STI-PA Analyzer

  5. Audio and Acoustic Analyzer • Sound Level MeterReal Time Analyzer • Acoustic Analyzer • STI-PA Analyzer • Audio Analyzer

  6. Applications • Live Sound Solutions • Sound Installations and Recording Studios • Broadcast • Environmental Noise Measurements • Service and Repair Centers

  7. + M2210 + M4260 Configurations • Set XL2 + M2210XL2 with M2210 - Extended Performance - Measurement Microphone withclass 1 frequency response • Set XL2 + M4260XL2 with M4260 Measurement Microphone, Class 2

  8. XL2 Interfaces

  9. Big LCD 160x160 • with Backlight • Function Buttons

  10. Rotary Wheel • Limit LED with • red, yellow, green • Indication

  11. Shock • Protection • Jacket

  12. Headphone • Output

  13. Wire Stand

  14. Battery Compartment • with Li-Po Battery • included • Rear Speaker

  15. Balanced & • Unbalanced Input • Tripod Mount

  16. Voice Note • Microphone

  17. Mains Power • Adapter Input • USB Interface • Digital I/O • (prepared for later • firmware extension)

  18. Mini-SD Card 2 GByte • Removable

  19. TOSLink Output • (prepared for later • firmware extension)

  20. XL2 Key Features

  21. Features • Flexible User Interface • Visual Limit LED of high sound levels • Mini-SD Card, 2 GB removable • Real Time Clock • Built-in Speaker • Rechargeable Li-Po Battery included • Automated Sensor Detection reads electronic data sheet of M4260 and M2210 • Wave File Recording* • Voice Notes* *optional

  22. Sound Level Meter / RTA • Applications • Live Sound Events • Environmental Noise Monitoring

  23. Sound Level Meter / RTA • Measures actual level, Leq, Lmin, Lmax, LCpeak, … • Frequency weightingA, C, Z • Time Weighting F, S, I* • Linearoperating range >100dB • XL2 accuracy acc. IEC 61672, class 1 • Logs automatically to Mini-SD card • Real time clock *optional

  24. Sound Level Meter / RTA Extended Acoustic Pack • Percentiles %: 1, 5, 10, 50, 90, 95, 99% • Time Weighting: Impulse • Sound Pressure Level LIeq • Sound Exposure Level LAE • TaktMax as specified in DIN 45645-1 • WAV-file recording (ADPCM) • Voice note recording • High-resolution FFT up to 0.3Hz steps

  25. Sound Level Meter / RTA • All measurement results are simultaneously available. • Select the available levels to be shown on the XL2 display

  26. Sound Level Meter / RTA • 3 or 5 levels may be displayed simultaneously in different selectable sizes

  27. Sound Level Meter / RTA • Displays two spectra simultaneously • Resolution selectable • Broadband values displayed in parallel • Measurement range selectable • Measurement time and control

  28. Sound Level Meter / RTA • Pre-defined limits for all levels • Firmware V1.00 operates with fixed limits • Level ok  Limit LED is GREEN • Level near limit  LED is YELLOW • Limit exceeded  LED is RED

  29. Live Sound Challenges Stage • Sound pollution protection limits maximum level in audience area. • Loudest audience position is commonly not accessible for measurements. • XL2 offers a wizard to measure correction values k1 and k2 between loudest position and measurement point Loudest accesible position  Audience position Measurement Position k1 = Difference in LAeq k2 = Difference in LCPeak FOH Public listeningarea

  30. Correction Factor Wizard • Run Pink Noise in the auditorium • Measure level at the loudest position • Measure level at the measurement point, e.g. at the mixing desk FOH • XL2 stores results with time stamp and displays the calculated correction values k1 and k2

  31. Audio Analyzer • Balanced XLR, unbalanced RCA input • -112 dBu to 30 dBu (1.4uV to 25V) • Residual THD+N <-100dB (0.001%) • Frequency range: 9 Hz to 20 kHz • Frequency accuracy: 0.003% • Loudspeaker and headset output for signal monitoring

  32. FFT Analyzer • Measures LZF and Leq simultaneously • Real time FFT in 3 ranges • 10 Hz - 220 Hzwith 1.5 Hz steps • 20 Hz - 1.7 kHzwith 15 Hz steps • 200 Hz - 20 kHzwith 150 Hz steps • High-resolution FFT including zoom mode up to 0.3 Hz stepswith Extended Acoustic Pack

  33. RT60 Analyzer • Measures 8 octave bands from 63 Hz – 8 kHz according to ISO3382 by Schroeder-method • Auto triggering • Auto averaging • Measurement error indication • Stimulus: • Gated pink noise • Impulse sound source

  34. Polarity Testing • Checks polarity of speaker cabinets, individual drivers and line signals • Positive/Negative detection • Using internal microphone or input signal of XLR/RCA connector

  35. Polarity Testing • In-depth verification of the polarity - frequency relation for speaker cabinets or other multi-way-systems • Sample Screenshot left:The major part of the signal energy is measured in the mid-range frequency bands, thus the overall displayed polarity is NEGATIVE.

  36. Propagation Delay • For accurate setup of delay line arrangements • Measures delay between electrical reference and acoustical signal • Relative measurements supported • Displays distance to speaker in meter or feet

  37. STI-PA Analyzer • Measures speech intelligibility of public announcement systems • Complies with IEC 60268-16 (2003) and NFPA 72 • Displays STI and CIS results • Shows table of modulation indices and Leq’s • Supports ambient noise post processing *optional

  38. Application Profiles • XL2 supports application profiles • Application profile may disable and hide any selections or measurement functions • Allows fixed operator interfaces for basic users • Firmware V1.0 offers a set of fixed application profiles

  39. Store and Log Results • Results stored as ASCII files • Storing all or subsets of measurements results • Adding a voice note to measurement* • Records the ADPCM compressed audio signal in parallel* *optional

  40. Automated Sensor Detection • Automatically detects microphone type • Reads sensitivity • Reads product data • Shows last calibration • ASD CableExtension cable tandem up to 20 m supported

  41. Powering Concept • Rechargeable Li-Po battery • included • typical battery lifetime > 5 hours • Dry cell batteries • type AA, 4 x 1.5 V • typical battery lifetime > 4 hours • Mains power supply 9 VDC • charges Li-Po battery in operation

  42. Measurement Microphones

  43. Measurement Microphones • Omni-directional, pre-polarized condenser, free-field microphone • Build-in Pre-amplifier • Electronic Data Sheet installed • Phantom Power 48 VDC • High dynamic range • Wide frequency range • Low residual noise M2210 M4260

  44. Comparison of Microphones

  45. XL2 Accessories

  46. Accessories • Ever-Ready pouch • Detachable front flap • Connectors accessible • Zipper • EXEL System Case • Compartments for XL2, MR-PRO, M4260 or M2210 • Accessories, battery and adapter

  47. Accessories • Battery Charger • Includes spare battery • Connects to 100-230V AC • Intelligent charger controller • Spare Battery • rechargeable spare battery • Li-Po battery

  48. Accessories • ASD Cable • For extended connections of the measurement microphones M4260 or M2210 • Maintaining the automated sensor detection • Length = 5 meter (16 feet) • External AC power supply • Suitable also for use with MR-PRO • Operates XL2 and chargers Li-Po battery in parallel

  49. Firmware Options • Extended Acoustic Pack • Percentiles: 1%, 5%, 10%, 50%, 90%, 95%, 99% • Time Weighting: Impulse • Sound Pressure Level LIeq, Sound Exposure Level LAE • TaktMax and values as specified in DIN 45645-1 • WAV-file recording (ADPCM) • Voice note recording for individual measurements • High-resolution FFT including zoom mode up to 0.3 Hz steps at 10 Hz - 20 kHz

  50. Firmware Options • STI-PA Option • Measures speech intelligibility of public announcement systems • Complies with IEC 60268-16 (2003) and NFPA 72 • Displays STI and CIS results