1 / 33

Paweł Pilewski Pre-Sales Engineer

Data Center. Paweł Pilewski Pre-Sales Engineer MICROSENS GmbH & Co. KG Phone: +4 8 71 337 16 71 Email: ppilewski @microsens. pl www.microsens.com. Optical Transport Positioning. With our switches we cover the LAN-area We terminate at the core switch of the building

Sophia
Télécharger la présentation

Paweł Pilewski Pre-Sales Engineer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DataCenter Paweł Pilewski Pre-Sales Engineer MICROSENS GmbH & Co. KGPhone: +48 71 337 16 71Email: ppilewski@microsens.pl www.microsens.com

  2. Optical Transport Positioning • With our switches we cover the LAN-area • We terminate at the core switch of the building • Optical transport opens the world to the WAN

  3. Data transport from LAN to WAN This model can be transferred to all branches (Industry, Oil and Gas, Education, Healthcare, Financial) District Office / HQ Local Office SDH Ethernet SAN Video OTN Regional Office WDM technology 10G / 100G 10G / 100G Benefits Local Office Local Office • We offer an additional value to our customers (end to end responsibility) • Reliable and secure transmission

  4. LAN • LAN • SAN • SAN • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric The benefits of WDM • Back-up DC may not be placed in the same campus • Need of many fibers in parallel • Very high rental costs

  5. FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric • FC fabric The benefits of WDM • Onlyonefiber (pair) required • WDM pays off in 12 -36 months • High capacity • Lesslatency • LAN • LAN • SAN • SAN • Each single „color“ has the same capacity as a fiber. • The 40 channel DWDM system has the same capacity as 40 single fibers

  6. WDM application fields r10G 3,000Km Long-haul INTER-CONNECT & COLO HEALTH Data Center Enterprise CONTENT DELIVERY FINANCIAL Metro Research & Education INTERNET2 MEMBER Backhaul/ Fronthaul CWDM DWDM ROADM MOBILE

  7. Data Center Interconnection Why do we need xWDM in DC? • Cost optimalization- OPEX • Flexible, Scalable architecture - easy upgrade • High reliability - a wide range of protection mechanisms • A wide range of modules dedicated to DRC applications

  8. Data Center Interconnection What is important for DC application? • Support for wide family of Ethernet and FC protocols • Secured managment system • Redundancy and reliability • Interoperability – Brocade certification • Security

  9. Data Center Interconnection Example: Answer is CXG+ module • 4 SFP+ interfaces • 1GBE, 10GBE, 1/2/4/8/16G FC supported • Transparent mode, no 3R • Dual converter • Point-to-Point, Ring, Star und meshed configurations • Distances depending on type of SFP/SFP+ and application protocol/speed • For best performance use SFP+ with integrated CDR

  10. 100G Solutions Cost-Effectively Add Capacity to Existing Systems 300 Km 100G TRP or MXP 100G TRP or MXP 100G Wavelength (Alien) 100G Wavelength (Alien) Existing WDM Network • Add 100G Capacity to Your Legacy Systems • Next Generation FEC allows exceptional 100G performance over your existing line systems; potentially eliminate multiple regen sites • 100G provides superior OSNR (~12.5 - 14dB) compared to existing 10G/40G channels • Only requires 200W and 1RU of space – no facility upgrade required

  11. 100G Solutions Extend the Life of Your Legacy Systems 100G MuxponderConfig 1…12 Client Ports 10G 10G 10G 10G 10G 10G 10G 10G Nine (9) Free Ports Now Available for Additional Equipment 10G 10G 10G 10G 10G 10G 10G 10G Benefits 10G 10G 10G 10G WDM Network • Extend the life of your legacy system • Inexpensive way to reclaim capacity • A repeatable, manageable solution • Leased fiber savings • Comes with all the MICROSENS technical advantages: NG FEC, wide Muxponder Family, etc.

  12. 200G Solutions Metro Access applications Muxponder • 20 X 10 GbE MXP, max. 4x 40G + 2x10G • 3-slot Module, Compatible with 7RU and new 2RU Chassis • Coherent technology • Client Interface Form factor: • SFP+ • 130W Power Draw • OSNR: 20 dB min • Max distance: 160km • PMD tolerance: 30 ps

  13. Data Center Interconnection What is important for DC application? • Support for wide family of Ethernet and FC protocols • Secured managment system • Redundancy and reliability • Interoperability – Brocade certification • Security

  14. Data Center Interconnection Example: Answer is NM3 module • Web Manager (HTTP/HTTPS) • Command Line Interface via Telnet/SSH/Console • SNMP v1/v2c/v3 with View-based Access Control Model (VACM) and User-based Security Model (USM) • Linux operating system • Users can be authenticated by the central TACACS+ server and user access may be restricted via Access Control List (ACL) • User authentication according to IEEE 802.1X

  15. Data Center Interconnection What is important for DC application? • Support for wide family of Ethernet and FC protocols • Secured managment system • Redundancy and reliability • Interoperability – Brocade certification • Security

  16. Data Center Interconnection • Line Protection • Channel Protection • System Protection

  17. ETR – Reliability… • CapEx Savings • No HVAC equipment needed • Reduce size and requirements of cabinet • OpEx Savings • No HVAC maintenance needed • For HVAC sites, ETR allows response teams more time to repair HVAC issues • Increased Revenue Opportunity • ETR will allow access to more remote sites Notice that everything is functioning without alarm

  18. Data Center Interconnection What is important for DC application? • Support for wide family of Ethernet and FC protocols • Secured managment system • Redundancy and reliability • Interoperability – Brocade certification • Security

  19. Data Center Interconnection http://www.brocade.com/downloads/documents/matrices/brocade-compatibility-matrix-fos-7x-mx.pdf

  20. Data Center Interconnection What is important for DC application? • Support for wide family of Ethernet and FC protocols • Secured managment system • Redundancy and reliability • Interoperability – Brocade certification • Security

  21. Data Center Interconnection Fiber Monitoring solution

  22. Fiber Security Solutions OM1: Monitoring of link attenuation OM1 OM1 DWDM DWDM NMP

  23. Fiber Security Solutions OM1: Information available in NMP Currentvalue Time since last threshold violation How long and howoften… Thresholdsconfiguration

  24. Fiber Security Solutions OM2: Spectrum Analyser • The OM2 is a standalone Spectrum Analyser. It can be connected to CWDM / DWDM links without interruption and then monitor the different wavelengths

  25. Fiber Security Solutions C/DWDM Optical Spectrum Analyser (OM2)

  26. CipherPilot Layer 2 Encryption Safeguards your data against espionage and changes. Can be used with Dark Fiber, WDM and Ethernet links. CipherPilots are available for all common protocol types such as ATM, SDH/SONET, Ethernet and Fibre Channel. Encryption takes place with the highest commercially available encryption grade of 256 Bit AES (automatic key change every minute). Hardware encryption is the fastest way to encrypt/decript with very low latency.

  27. Clear data (not encrypted) Safe data (encrypted) WDM plus Encryption Support of: ATM/SDH: STM-1/-4/-16/-64 Fibre Channel: 1G/2G Ethernet: 10M/FE/GbE/10GE FE FC-2G C/DWDM STM-4 GbE GbE 10GE Encryptors Encryptors C/DWDM 1 Pair of encryption devices per application

  28. Encryption Levels Frame Mode LAN Mode Tunnel Mode

  29. Key Functions CipherPilot Platform • Tamper proof enclosure: The 256 bit host key must be safe under all circumstances. Therefore, the unit is designed to forget its key as the cover is opened. • SNMP V2c / V3: Read only function. With V3 the management data is encrypted. • Automatic Key Change: Even if the data where tapped and even if the key would be known only the data for one minute could be decoded. • All important protocols available: Despite a heterogeneous topology the customer needs only products from one supplier. • High data rate: The CipherPilots encrypt data in real time with minimal latency. • Automatic operation: After the quite easy initial installation no further attention is required. Even after a cable break or power up the keys will be automatically synchronized.

  30. Ethernet Encryption Applications Point-to-point Networks Point-to-multipoint Networks Multipoint Networks

  31. Data Center Interconnection What is important for DC application? • Support for wide family of Ethernet and FC protocols • Secured managment system • Redundancy and reliability • Interoperability – Brocade certification • Security

  32. Benefits Why MICROSENS? • Best-in-Class coherent optical technology • Solutions that require minimum space & power • Deployable in all environments (ETR) • Flexibility & scalability • Unmatched 100G density • Easy to deploy & manage • One NMS and 2 platforms

  33. Thank you!

More Related