1 / 27

Efficient On-line Interconnect BIST in FPGAs with Provable Detectability for Multiple Faults

Efficient On-line Interconnect BIST in FPGAs with Provable Detectability for Multiple Faults. Vishal Suthar and Shantanu Dutt Dept. of ECE University of Illinois at Chicago. Outline. On-Line BIST – Concepts Previous Work in Interconnect BIST New Interconnect BIST: I-BIST Motivation

allene
Télécharger la présentation

Efficient On-line Interconnect BIST in FPGAs with Provable Detectability for Multiple Faults

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Efficient On-line Interconnect BIST in FPGAs with ProvableDetectability for Multiple Faults Vishal Suthar and Shantanu Dutt Dept. of ECE University of Illinois at Chicago

  2. Outline • On-Line BIST – Concepts • Previous Work in Interconnect BIST • New Interconnect BIST: I-BIST • Motivation • Types of faults • On-line issues • Global Testing • Detailed Testing • Simulation results • Conclusions

  3. C T O C CUT TPG WUT ORA CUT WUT Pass / fail On-line Built-In Self-Testing in FPGAs • Two column left spare for ROTE; one for • fault reconfiguration • ROTE roves across the FPGA • In each session diff. PLBs act as CUTs, • TPG and ORA. ROTE (ROving TEster) BISTer: TPG - Test Pattern Generator ORA - Output Response Analyser CUT - Cells Under Test T C C O SPARECOLUMN SPARECOLUMN WUT - Wires Under Test CIRCUIT CIRCUIT CIRCUIT WUT WUT

  4. Interconnect BIST-- Motivation • Interconnects occupy ~ 90% of FPGA area • Multiple faults can easily occur for current and emerging nano-meter FPGAs; no current work detects all multiple faults • Many PLB BIST work, but much fewer on interconnect BIST

  5. many Interconnect BIST– Past Work • Only few on-line interconnect BIST methods • # configurations high for previous on-line interconnect BIST: 10 for [Liu et al., CICC’01] • # of test vectors high for all previoys interconnect BIST • No prev. method has guarantd. 100% fault detectability for multiple faults • Fault diagnosability (% of faults correctly located) low for past methods • Our interconnect BIST method I-BIST will address and improve on all these issues

  6. I-BIST – Objectives & Flow • Objectives: • To maximize diagnosability, even in presence of multiple faults, by avoiding • fault masking scenarios. • To reduce test time. • Dominant component of test time = configuration time • Hence minimize # configurations. • Secondary objective: minimize # test vectors. Approach: 1. First isolate the possible fault locations to a small set of interconnects in very few configurations -> Suspect Set, 2. Then diagnose interconnects of suspect set for faults. -- Global testing -- Detailed testing

  7. I-BIST – Interconnect Faults • Testing wire-segments and switches • Faults considered: wire-segment -> stuck-at, stuck-open and bridged fault • switches -> stuck-open and stuck-closed.

  8. Roving Tester Positions for I-BIST • Typical FPGA contains single-length, double-length and long wires. • whereas, a ROTE can occupy only two to three columns. • Hence, two types of ROTE are required: V-ROTE and H-ROTE

  9. I-BIST – Tested Interconnects V-Set: Interconnects tested under V-ROTE • Uncovered switches are covered in the next ROTE position or in the H-ROTE

  10. Test vector 1: 1 0 1 0 Test vector 2: 0 1 0 1 I-BIST – Global Testing: Idea • Multiple nets are formed • Multiple ORAs each comparing adj. nets • ORAs configured for 2-input XOR function • Pass complementary vectors on each adj. • net • => 2 test vectors {0101..} & {1010…}

  11. Test vector 1: 1 0 1 0 Test vector 2: 0 1 0 1 n n n n 4 2 1 3 X X 0 1 0 TPG 0 0 1 ORA 1 w 1 ORA 2 Fail bridge w 2 ORA 3 I-BIST – Global Testing: Idea • Consider ORA(n2, n3) • Under fault-free conditions • ORA (2-ip XOR) output = 1 1 • Wire stuck-at fault @ n2 • ORA output = 0 1 (n2 stuck-at-0) • = 1 0 (n2 stuck-at-1) • Multiple stuck-at fault on n2 is going • to result in one type dominating at • the ORA input • Wires bridge fault • ORA output = 0 0

  12. Test vector 0: 0 0 0 0 Test vector 1: 1 0 1 0 Test vector 2: 0 1 0 1 n n n n 4 2 1 3 1 0 0 1 0 TPG 0 0 1 ORA 1 w 1 ORA s-a-1 2 s-a-0 Fail w 2 ORA 3 I-BIST – Global Testing: Idea • Under fault-free conditions • ORA (2-ip XOR) output = 1 1 • Exception: one of the adjacent wire is • s-a-0 and other is s-a-1. • output = 1 1 = fault-free output • one more test vector required {0000…} or {111…} • Unexpected-comparison based test vectors • Fault-free output = 0 1 1 • Faulty output = 1 1 1

  13. Test vector 0: 0 0 0 0 Test vector 1: 1 0 1 0 Test vector 2: 0 1 0 1 n n n n 4 2 1 3 0 1 0 TPG 0 0 1 ORA 1 w 1 ORA 2 Stuck-open Fail pass w 2 ORA 3 I-BIST – Global Testing: Idea Stuck-open fault: • Assunption: Stuck-open fault essentially • results in a s-a-0 fault in the affected part • Only detected if present between TPG • and ORA • A second stage of global testing reqd. • Switch stuck-open faults that are part • of the nets are similarly detected • All switches are included in some net • across 5 configurations of net patterns

  14. I-BIST – Global Testing: Idea (contd) n n n n n n n n 4 4 2 2 1 1 3 3 w w 1 1 w w 2 2 Stuck-open fault (contd): Two stages of global testing phase needed – can be done simultaneously 0 0 1 0 1 0 TPG 0 0 0 0 1 1 ORA ORA 1 1 ORA ORA 2 2 Stuck-open Stuck-open Fail Fail ORA ORA 3 3 TPG

  15. n n n n 4 2 1 3 0 1 0 TPG 0 0 1 ORA 1 w 1 ORA Stuck-closed 2 w 2 ORA 3 I-BIST – Global Testing: Idea (contd) Switch stuck-closed fault: • Unlike other faults, switch stuck-closed • fault cannot be detected by including the • switch on a net

  16. I-BIST – Global Testing: Idea (contd) Switch stuck-closed fault (contd): • Unlike other faults, switch stuck-closed • fault cannot be detected by including the • switch on a net • Form nets in such a way that a • switch stuck-closed fault bridges the • two nets. • We refer to such switches as • Spanning switches

  17. I-BIST – Global Testing: Properties Theorem:Any number of faults in each net tested will be detected by the multiple ORA technique of global testing. Furthermore, a stuck-closed fault in any spanning switch between every pair of nets compared by an ORA will also be detected. Corollary:Fault masking cannot occur in global testing, even in presence of faults of the same type.

  18. Global Testing Dual-type multiple ORA technique • multiple nets formed • similarly configured nets – • net-set e.g. net-sets n & l

  19. Global Testing Dual-type multiple ORA technique • Two types of ORA comparison: • 1. Intra-net-set comparison • Adjacent nets of same net-set • compared • E.g., • target: all faults other than switch • stuck-closed fault • Inter-net-set comparison • Nets i of the two net-sets compared • E.g. • target: switch stuck-closed faults • in spanning switches

  20. Global Testing – Five Configurations Theorem:Any # of fault(s) in the V-set (interconnects tested in V-ROTE) will be detected by the 5 configurations of the global testing phase.

  21. Suspect interconnect Fault-free interconnect Detailed Testing • Diagnose faults on faulty nets of global testing phase. • Simple approach: Flat intersection • Suspect set = interconnects of failed nets found in global testing phase • Each interconnect element of suspect set compared with fault-free components. Drawback: Suspect set may be too large, even in presence of few fault.

  22. Detailed testing – Divide & Conquer (D&C) Better approach: Divide & Conquer ( D & C) O O • Failed nets divided into 2 sub-nets • Failed configurations re-applied independently on both sets of sub-nets. • Only the comparisons that failed in global testing phase are reqd. • Switches between the two sub-nets tested using same configurations minimized to two rows A O

  23. Detailed Testing – D&C (contd): Global testing Detailed testing O O O Switch stuck-closed O A O

  24. Simulation Setup • Simulated a 32 x 32 FPGA with single-length segments in C • Fault injector injects faults in wire segments and switches randomly at the specified fault probability (density/100)

  25. Simulation Setup and Fault Latency Results • Simulated a 32 x 32 FPGA with single-length segments in C • Fault injector injects faults in wire segments and switches randomly at the specified fault probability (density/100) Fault latency ( # configurations) vs. Fault density

  26. Analytical Results & Comparison to Prev Work many Overall Fault Diagnosability Results Fault coverage (diagnosability) versus fault density

  27. Conclusions • Presented a new interconnect BIST technique I-BIST for FPGAs—uses a hierarchical, adaptive approach, unexpected-comparison based test vectors • Applicable to both on-line and off-line BIST • I-BIST has 100% guaranteed fault detectability in the presence of multiple faults – a first • I-BIST has ~ 100% fault diagnosability (empirically) • I-BIST has the fewest configurations—5—per WUT-set in global testing • I-BIST has the fewest # of test vectors—3—per WUT-set testing phase • I-BIST uses an adaptive D&C phase in detailed testing to home in to the offending faults quickly • New work: Combined PLB and interconnect BIST w/o fault-free assumptions about any components—to appear at VTS’06