1 / 32

New Hybrid IP PBX KX-TDA30

New Hybrid IP PBX KX-TDA30. Panasonic Communications Co., Ltd. Network Business Company Edition 1.0 5 Mar., 2004. “. Remote Programming. PC Console/PC Phone. T76 series. DPT. USB. DPT. XDP. Modem. T72/T74/T75/T76. System Connection. PSTN. Branch. Private Network. Analog/BRI.

alva
Télécharger la présentation

New Hybrid IP PBX KX-TDA30

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New Hybrid IP PBXKX-TDA30 • Panasonic Communications Co., Ltd. • Network Business Company • Edition 1.0 5 Mar., 2004 “

  2. Remote Programming PC Console/PC Phone T76 series DPT USB DPT XDP Modem T72/T74/T75/T76 System Connection PSTN Branch Private Network Analog/BRI V.90 Modem/ISDN BRI IP Network Door Phone/Door Opener VoIP Card Battery CTI Client NewCS LAN T76 series CTI Server DXDP DPT USB USB/PT-USB/RS232C PC Programming Voice Mail APT/SLT MOH EPG Input/Output Terminals ISDN S0 Bus ISDN Tele. 0

  3. Differences between TDA30 and TDA100/200 Item TDA30 TDA100/200(Ver1.0) Initial Configuration 0CO - 4EXT With Power Supply 0CO - 0EXT No Power Supply Trunk Analogue/BRI Analogue/BRI, PayTone/E&M/E1/PRI Extension DHLC(MAIN) DLC/SLC DLC/SLC/DHLC MSLC PT i/f CS Yes No (Ver1.1) Ext. Caller ID Yes No (Ver2.0) DXDP Yes No (Ver1.1) VoIP card New 4ch IPGW 4ch/2slot CTI-Link card No Yes OPB3 card Not Necessary Necessary

  4. System Capacities 12 Max. Trunk Trunk - Max.12 = Analogue(Max.12) + ISDN-BRI(Max.6ports/12ch) 28 Max. Extension Extension Ports - PT : Max.24 = DPT + APT + DSS + VM(DPT) + CS(TDA0141) - SLT : Max.24 = SLT + VM (DTMF) 4 Max. IPGW IPGW (It is separated from Trunk) - IPGW : 1 x 4ch

  5. Port Configuration CO Port Extension Port 12 CO 24 Extension + 4SLT(XDP) LCOT4/BRI2 4 Port Extn SLC8 / DLC8 LCOT4/BRI2 DHLC4 (Built In) SLC8 / DLC8 LCOT4/BRI2 8 CO 20 Extension + 4SLT(XDP) LCOT4/BRI2 SLC8 / DLC8 LCOT4/BRI2 DHLC4 (Built In) SLC8 / DLC8 4 CO IPGW-4 LCOT4/BRI2 16 Extension + 4SLT(XDP) 4 Port Extn DHLC4 (Built In) SLC8 / DLC8 12 Extension + 4SLT(XDP) DXDP-DPT Extension DHLC4 (Built In) SLC8 / DLC8 DXDP Extension can be connected to KX-T76xx on DLC4 / DLC8 and DHLC4additionally.PT include DXDP-DPT + SLT port include SLT on DHLC (XDP On or Off) must be 28 or less than 28. 8 Extension + 4SLT(XDP) 4 Port Extn DHLC4 (Built In) 4 Extension + 4SLT(XDP) DHLC4 (Built In)

  6. Slot CO Trunk CO-1 CO-2 CO/Ext IPGW BRI Analog Total 01 - - - - 0 0 0 02 BRI-2 - - - 4 0 4 03 BRI-2 BRI-2 - - 8 0 8 04 BRI-2 BRI-2 BRI-2 - 12 0 12 05 LCOT-4 - - - 0 4 4 06 LCOT-4 LCOT-4 - - 0 8 8 07 LCOT-4 LCOT-4 LCOT-4 - 0 12 12 08 BRI-2 LCOT-4 - - 4 4 8 09 BRI-2 BRI-2 LCOT-4 - 8 4 12 11 4 4 4 YES 12 16 10 BRI-2 LCOT-4 LCOT-4 - 4 8 12 CO Line Configuration(1/1) CO Trunk Without IPGW card CO Trunk With IPGW card

  7. With DXDP Slot Without DXDP Built-in Line/Ext. Ext.-1 Ext.-2 SLT D-PT SLT D-PT 01 4S/4D - - - 4 4 4 8 02 4S/4D SLC(S4) - - 8 4 8 8 03 4S/4D SLC(S4) SLC(S8) - 16 4 16 8 04 4S/4D SLC(S4) DLC(D8) - 8 12 8 20 05 4S/4D SLC(S4) SLC(S8) SLC(S8) 24 4 24 4 06 4S/4D SLC(S4) SLC(S8) DLC(D8) 16 12 16 12 07 4S/4D SLC(S4) DLC(D8) DLC(D8) 8 20 8 20 4S/4D DLC(D4) - - 4 8 4 16 08 4S/4D DLC(D4) SLC(S8) - 12 8 12 16 09 4S/4D DLC(D4) DLC(D8) - 4 16 4 24 10 4S/4D DLC(D4) SLC(S8) SLC(S8) 20 8 20 8 11 4S/4D DLC(D4) SLC(S8) DLC(D8) 12 16 12 16 12 4S/4D DLC(D4) DLC(D8) DLC(D8) 4 24 4 24 13 Extension Configuration(1/2) Max. Extensions : 28

  8. With DXDP Slot Without DXDP Built-in Line/Ext. Ext.-1 Ext.-2 SLT D-PT SLT D-PT Extension Configuration(2/2) 14 4S/4D - SLC(S8) - 12 4 12 8 15 4S/4D - SLC(S8) SLC(S8) 20 4 20 8 16 4S/4D - SLC(S8) DLC(D8) 12 12 12 16 17 4S/4D - DLC(D8) - 4 12 4 24 18 4S/4D - DLC(D8) DLC(D8) 4 20 4 24 Max. Extensions : 28

  9. AC Adapter Selection AC Adaptor Capability Supplied AC Adaptor only : Max. 32 power units Supplied AC Adaptor + Additional AC Adaptor : Max. 96 power units SLT T76xx & T7560/T7565 Other type DPT/APT and DSS CS TDA0141 ISDN Terminal Total Power units Additional Adapter Power unit 0 0 4 4 1 AC Adapter Selection Sample 1 0-24 24 0 0 0 0 No 2 0-24 0 Max 4 Max 4 0 32 No 3 0-24 0 Over 4 0 0 - Yes - Yes 4 0-24 0 0 Over 4 0 5 0-24 0 4 4 1 33 Yes 6 0-24 0 4 3 4 32 No 7 0-24 0 4 3 5 33 Yes 8 0-24 0 3 4 4 32 No 9 0-24 0 3 4 5 33 Yes ISDN Terminal : When a BRI port is configured as “internal ISDN” and feeds DC power. Power unit of TVP connection is “0”.

  10. Front view of TDA30.

  11. SD Card Holder USB EPG RS232C MOH Reset SW Power SW Battery Backup connector for KX-A228 AC Power adaptor Additional AC adaptor KX-A236 Card Configuration(Front / Rear View) • - DLC4 (Max.1) • SLC4 (Max.1) • BRI2 (Max.3) • - LCOT4 (Max.3) - DLC8 (Max.2) - SLC8 (Max.2) - IP-GW4 (Max.1) • - EXT-CID (Max.1) • ECHO8 (Max.1) • - MSG2 (Max.2) • - DPH2/4 (Max.1) Front (DLC8 + SLC8 : Max.2) (DLC4 + SLC4 : Max.1) S-11 No DPH2/4 S-4 S-7 S-10 CO4/EXT4 EXT8/ IPGW4 No DPH2/4 S-3 S-6 S-9 CO4/EXT4 EXT8/ IPGW4 S-2 S-5 S-8 CO4/EXT4 EXT8/ IPGW4 S-1 DHLC4 (Fixed Slot) Rear Initialize SW Battery charging Current :200mA(Half of TDA100/200)

  12. Card Configuration(Top View) RMT MAIN Board • Power Supply • +40V input • (2-DC-IN) • +3.3V • +5V • +15V • +9V/-9V • Ringer Generation • MEC i/f RMT i/f • MPR(CPU) Block • Similar to TDA100/200 • Processor • Memories • ASIC(TSW, Conf, Ext etc) • SD card i/f • Serial / USB i/f • MOH/Page port(*1ch each) • RMT card i/f • Expansion Memory(MEC) • i/f(for Ver1.1) Back Board Function Free Slot(Type A) (3) Free Slot (Type B)(3) • [SLOT1] • Built-in Ext Block • DHLC4 • Terminal • CS / VPS / APT / DSS • SLT/DPT • Two PF Transfer • ports • [SLOT2] • 4 port Ext Card • (Max 1 card) • DLC4 • SLC4 • or • LCOT4/BRI2 Card • (Max 3 cards). [SLOT5] 8 port Extension Card (Max 2 cards) -DLC8 -SLC8 or IP-GW4 Card (Max 1 card) • [SLOT3] • 4 port Ext Card • (Max 1 card) • DLC4 • SLC4 • or • LCOT4/BRI2 Card • (Max 3 cards) [SLOT6] 8 port Extension Card (Max 2 cards) -DLC8 -SLC8 or IP-GW4 Card (Max 1 card) • [SLOT4] • 4 port Ext Card • (Max 1 card) • DLC4 • SLC4 • or • LCOT4/BRI2 Card • (Max 3 cards) [SLOT7] 8 port Extension Card (Max 2 cards) -DLC8 -SLC8 or IP-GW4 Card (Max 1 card) Option Slot(4) Option Base Function DPH4 / DPH2 / MSG2 / ECHO8 / EXT-CID No need OPB3 card which required for TDA100/200 • [SLOT8] • Option Card • DPH2/4 (Slot8,9 only) • MSG2 (Max 2 cards) • ECHO8 • EXT-CID • [SLOT9] • Option Card • DPH2/4(Slot8,9 only) • MSG2 (Max 2 cards) • ECHO8 • EXT-CID • [SLOT10] • Option Card • (Not Available DPH2/4) • MSG2 • ECHO8 • EXT-CID • [SLOT11] • Option Card • (Not Available DPH2/4) • MSG2 • ECHO8 • EXT-CID Caller ID Card for LCOT4 Caller ID Card for LCOT4

  13. Model Number of TDA30 and TDA200 Extension Trunk Card TDA30 TDA100/200 Card TDA30 TDA100/200 DHLC8 - TDA0170 LCOT4 TDA3180 - - DLC4 TDA3171 LCOT8 - TDA0180 DLC8 TDA3172 TDA0171 LCOT16 - TDA0181 DLC16 - TDA0172 E&M - TDA0184 SLC4 TDA3173 - E1 - TDA0188 TDA0173 SLC8 TDA3174 CID/PAY8 - TDA0189 SLC16 - TDA0174 CID(CO) TDA3193 TDA0193 MSLC16 - TDA0175 BRI2 TDA3280 - CSIF8 - TDA0144 BRI4 - TDA0284 Others BRI8 - TDA0288 Card TDA30 TDA100/200 PRI30 - TDA0290 OPB3 - TDA0190 IP-GW4 TDA3480 TDA0480 DPH4 TDA3161 TDA0161 DPH2 TDA3162 TDA0162 ECHO TDA3166 TDA0166 EXT-CID TDA3168 - MSG TDA3191 TDA0191 RMT TDA3196 TDA0196 CID(CO) TDA3193 TDA0193 CTI-Link - TDA0410

  14. System Hardware -1 Trunk Cards BRI-2 KX-TDA3280 Max.3 - 2 Port ISDN BRI Card - CO/Extension (Programmable) - RJ45 x 2 - 1 Power failure port LCOT4 KX-TDA3180 • 4 Port Analogue CO Card • RJ11 x 4 - Line polarity reverse detection • CPC detection. • CID4 card can be mounted. - 2 Power failure port Max.3 Caller ID Card KX-TDA3193 - Bell / ETSI / DTMF • Mounted on LCOT4 Max.3 IP-GW4 KX-TDA3480 - 4ch IPGW Card • G.729a/G.723.1/G.711 • 100BaseTX/10BaseT • FAX : G7.11 (T.38 is not supported) - Web programming(English only) Max.1 Note : All cards for TDA30 are NOT hot swappable.

  15. System Hardware -2 Extension Cards DLC4 KX-TDA3171 - 4 Port DPT Card • DPT / DSS / CS / VPS (DPT Integration) - RJ11 x 4 Max.1 DLC8 KX-TDA3172 - 8 Port DPT Card • DPT / DSS / CS / VPS (DPT Integration) - RJ11 x 8 Max.2 SLC4 KX-TDA3173 - 4 Port SLT Card - 4 DTMF receiver - RJ11 x 4 Max.1 SLC8 KX-TDA3174 - 8 Port SLT Card - 8 DTMF receiver - RJ11 x 8 Max.2 Note : Optional DHLC card is not provided. Note : All cards for TDA30 are NOT hot swappable

  16. Available Terminals for Extension Cards Name Explanation CS DPT VPS APT DSS SLT DHLC Digital Hybrid Line Circuit (Super Hybrid Port) v v v v v v DLC Digital Line Circuit v v v v SLC SLT Line Circuit v Note : PC Phone and PC Console belong to DPT

  17. System Hardware -3 Optional Cards-1 MSG2 KX-TDA3191 - 2 Port Message/DISA Card • OGM Max.15min, 32messages Max.2 DPH4 KX-TDA3161 - 4 Port Doorphone Card - Doorphone for T30865 - 4 Door Opener - 4 External Relay Output (Ver.2.0) • 4 External Sensor Input (Ver.2.0) Max.1 DPH-2 KX-TDA3162 - 2 Port Doorphone Card - Doorphone for Germany Type - 2 Door Opener - 4 External Relay Output (Ver.2.0) - 4 External Sensor Input (Ver.2.0) Max.1 ECHO8 KX-TDA3166 • 8 Port Echo Cancelling Card Max.1 Note : All cards for TDA30 are NOT hot swappable

  18. System Hardware -4 Optional Cards-2 Ext. Caller ID KX-TDA3168 - Caller ID signal generator Card • Max. 8 SLT (4ports x 2resources) • FSK Signal V.23(ETSI)/Bell202 (Bellcore) (1st Bell -- Caller ID -- 2nd Bell) Max.1 RMT KX-TDA3196 - Analogue Modem Card. • V.90 Support. Max.1 Note : All cards for TDA30 are NOT hot swappable Additional AC Power Adaptor (Same as packed adaptor) KX-A236 Condition KX-A236 is required if (1) Total number of APT, DSS, DPT(T72xx, T74xx,T75xx) exceeds 4, or (2) Total number of CS exceeds 4. Max.1

  19. System Capacities (Resources) -1 Resources TDA30 TDA100 /200 Resources TDA30 TDA100/200 MOH Port 1 2 Tenant 8 Pager Port 1 2 COS 64 DSS/PC Console 4/2 8 Trunk group 64 PC Phone 24 64/128 Ext. use group 32 Doorphone 4 8/16 Paging group 32 Door opener 4 8/16 PS ring group 32 DISA Ports 4 8/16 Call pick up group 64 OGM 32 64 Idle Ext. Hunting-G 64 (16 Ext./G) CS 8/4 16/32 ICD-Group 64 (32 Ext./G) PS 28 64/128 Queuing time table 64 VPS Unit 1 2 VPS (DTMF) 2 (32 Ext./G) Port (Ch) 4 (8ch) 12 (24ch) Ext. Number digits 1-4 Call park area 100 Conference 3x10 or 8x4 MSG waiting Log. 256 SMDR Buffer 200

  20. System Capacities (Resources) -2 Resources TDA30 TDA100/200 Resources TDA30 TDA100/200 Verified user code 4 digits x 1000 Toll Restriction level 7 Verified code PIN 10 digits x 1000 Denied Code 16digitsx100/level Special carrier code 16 digits x 20 Exception Code 16digitsx100/level Host access code 10digitsx10/TRG Charge Rate 8 digits DDI table 32 digits x 1000 Denomination 3 Emergency dial 32 digits x 10 Call Log (Outgoing) 100/Ext. Quick dial 4 digits x 80 Call Log (Incoming) 100/Ext. System speed dial 32 digits x 1000 Pick up dial 32 digits Redial 32 digits ARS plan 16 Leading digit 16 digits x 1000 Excepted leading 16 digits x 200 ARS Carrier 10 TIE Routing Table 32 Leading digits 3 PBX Code 7

  21. Maximum Cabling Distance ø0.4mm 500m ø0.5mm 720m (CAT5) ø0.6mm 830m - T76xx Series - T7550/T7565 ø0.4mm 140m ø0.5mm 229m (CAT5) ø0.6mm 360m - Other D-PT/A-PT - All DSS ø0.4mm 698m ø0.5mm 1128m (CAT5) ø0.6mm 1798m SLT ø0.4mm 222m ø0.5mm 347m (CAT5) ø0.6mm 500m TDA0141(CS) 5m USB Point to Point 1000m (CAT5) Point to Multi-Point 150m (CAT5) ISDN Terminal ISDN S0 Bus 5m USB Terminal USB USB Terminal

  22. New Feature1: Digital eXtra Device Port (DXDP) - Two DPTs on a DLC port - Two DPTs and One SLT on a DHLC port DXDP-Slave DXDP-Master 1 pair 1 pair DXDP-Slave DXDP-Master XDP or Parallel 2 pair 2 pair 1 pair Note : Master extension is the party of "Parallel connection" SLT.

  23. DXDP-Master XDP DXDP-Slave DXDP-Connection & Extension Number Assignment DXDP-Master DXDP-Slave XDP

  24. Telephone Master Slave Available • - T7625 • - T7630 • - T7633 • T7636 • T7665 - T7625 - T7630 - T7633 - T7636 - T7665 Not Available • - APT • - T72xx • - T74xx • DSS • CS • TVP • - APT • - T72xx • - T74xx • DSS • CS • TVP DXDP- Conditions ø0.4mm Max.40m ø0.5mm Max.50m ø0.6mm Max.60m Condition-1 ø0.4mm Max. 500m ø0.5mm Max. 720m ø0.6mm Max. 830m DXDP-Slave DXDP-Master Condition-2 Condition-3 If you use DXDP, - OHCA function is not Available. - T7601 (USB) is not Available. (PC Phone / PC Console / PC Programming) Parallel Wiring is NOT Available Condition-4 X

  25. Max.8 CS with Two AC adaptors - CS Port assignment is not necessary. TDA30 automatically detects the CS connection. New Feature2: PT Interface DECT CS (KX-T0141) • - No CS Interface card necessary. • - Connect CS to Extension port: DHLC4, DLC4/8 • Two Voice Channels per a CS. • 1 pair cable wiring(Same as DPT) ø0.4mm 222m ø0.5mm 347m ø0.6mm 500m Max.4 CS with One AC adaptor

  26. New Feature3: Caller ID for SLT With KX-TDA3168, TDA30 provides CLIP information for SLT. Caller ID Signal EXT-CID Resource assignment EXT-CID card has 2 resources (“for 4ports” x2), the resources assignment for SLT extension card is necessary. MAIN SLC4 TDA3168 SLC8-1 (1-4) SLC8-1 (5-8) SLC8-2 (1-4) 2 resources SLC8-2 (5-8)

  27. Parallel mode Ext.201 Ext.201 XDP mode Ext.201 Ext.205 1st Call 2nd Call Caller ID for SLT (KX-TDA3168) -2 Enable/Disable We enable/disable port by port. Timer=0: 1st call Ring  1st caller disconnects  2nd call Ring Timer=5: 1st call Ring  1st caller disconnects wait 5sec 2nd call Ring

  28. New Feature4: New IP-GW Card (KX-TDA3480) - 4ch IP-GW Card - G.729a/G.723.1/G.711 - T.38 (FAX) mode is not supported (FAX = G.711) - Web programming (English only) - Interoperability with TDA0480: Incoming call, Outgoing call and CLIP only. - Interoperability with another manufacturers : Not guaranteed. Conditions

  29. KX-TDA100/200 KX-TDA30 Features Not Supported by KX-TDA30 - The KX-TDA30 does not support the MSLC Functionality. Therefore it will not support the KX-T7710, with its 90V neon message waiting light.

  30. Language data We can use the TDA100/200 language data. Optional Card data System data TDA0141 program System program PBX SD card data

  31. Optional Card Software - All Optional Cards (Except IPGW) are controlled by MAIN CPU. PC Programming Software - Proprietary, but similar to TDA100/200 PC programming software. Maintenance Commands -The TDA30 PBX maintenance commands are the same as TDA100/200

  32. Thank you.