An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New Hybrid IP PBXKX-TDA30 (Ver.1.0) Panasonic Communications CO., (UK) LTD. “

  2. TDA100 TDA30 TDA200 March/2003 March/2003 Dec/2003 TDA30 V1.0 TDA200 TDA100 Trunk 128 64 Extension 128 64 CO 0 0 0 Extension 0 0 DHLC-4 (SLT 4 + DPT4) Hybrid IP-PBX KX-TDA Series and Plan V1.0 Networking(QSIG), Call Center, VoIP Gateway, CTI (CSTA/TAPI), T76xx Line Up V1.1 Digital XDP, DECT CS to D-PT Port. V2.0 Extension IP Support, Hotel Features Port Max. TDA30 12 28 (SLT 24+DPT 24) Initial Configuration “

  3. SOHO Solution Powerful Hybrid IP PBX KX-TDA30 • Take Over TDA100/200 Features • Flexible Optional Slots • Flexible Extension Configuration • DXDP is supported from Ver.1.0 • D-PT I/F CS (TDA0141) • Caller ID for SLT line • PCC proprietary IPGW card Expanding ISDN-SOHO Market

  4. Remote Programming System Connection PSTN/ISDN ISDN Analog Private Network Branch Analog/BRI BRI External I/O Device(V2.0) (Sensor/Relay) CO Trunk IP Network VoIP Card Door Phone/Door Opener Battery PC Console/Phone Option I/F CTI Client New DPT USB New CS LAN New DPT DXDP CTI Server USB USB/PT-USB XDP Modem PC Programming APT/SLT T72/T74/T75/T76 Voice Mail MOH ISDN Tele. EPG Input/Output Terminals ISDN S0 Bus “ 0

  5. Resources TDA30 TDA100/200 Resources TDA30/100/200 MOH Port 1 2 Tenant 8 Pager Port 1 2 COS 64 Trunk group 64 DSS/PC Console 4/2 8/8 Ext. use group 32 PC Phone 24 64/128 Paging group 32 Doorphone 4 8/16 PS ring group 32 Door opener 4 8/16 Call pick up group 64 DISA Ports 4 8/16 Idle Ext. Hunting-G 64 (16 Ext./G) OGM 32 64/64 ICD-Group 64 (32 Ext./G) CS 8 16/32 Queuing time table 64 PS 28 64/128 VM (DTMF) 2 (32 Ext./G) VM Unit 1 2 Ext. Number digits 1-4 Port (Ch) 4 (8ch) 12 (24ch) Call park area 100 MSG waiting Log. 128 256 Conference 3x10 or 8x4 SMDR Buffer 100 200 System Capacities / Resources -1 Trunk - Max.12 = Analog 12 (Max.) + ISDN 6 ports (Max.) - IPGW : 1 x 4ch Extension Ports - D-PT : Max.24 = D-PT + A-PT + DSS + VM (D-PT) + CS (TDA0141) - SLT : Max.24 = SLT + VM (DTMF)

  6. Resources TDA30/100/200 Resources TDA30/100/200 Verified user code 4 digits x 1000 Toll Restriction level 7 Verified code PIN 10 digits x 1000 Denied Code 16digitsx100/level Special carrier code 16 digits x 20 Exception Code 16digitsx100/level Host access code 10digitsx10/TRG Charge Rate 8 digits DDI table 32 digits x 1000 Denomination 3 Emergency dial 32 digits x 10 Call Log (Outgoing) 100/Ext. Quick dial 4 digits x 80 Call Log (Incoming) 100/Ext. System speed dial 32 digits x 1000 Pick up dial 32 digits Redial 32 digits ARS plan 16 Leading digit 16 digits x 1000 Excepted leading 16 digits x 200 ARS Carrier 10 TIE Routing Table 32 Leading digits 3 PBX Code 7 System Capacities / Resources -2

  7. System Hardware -1 Trunk Cards BRI-2 KX-TDA3280 - 2 Port ISDN BRI Card - CO/Extension (Programmable) - RJ-45 x 2 - Power failure port is supported. Max.3 LCOT-4 KX-TDA3180 - 4 Port Analog CO Card - RJ-45 x 4 - Power failure port is supported. - Line polarity reverse detection - CPC is not supported. Max.3 Caller ID Card KX-TDA3193 - Bell / ETSI / DTMF - Mounted on LCOT-4 IPGW-4 KX-TDA3480 - 4ch IPGW Card - G729a/G723.1/G711 - T.38 : Not supported - Physical i/f: 10/100 Base-T - Web programming (English) Max.1 Note : All cards for TDA30 are NOT hot swappable

  8. System Hardware -2 Extension Cards DLC-4 KX-TDA3171 - 4 Port D-PT Card - D-PT / DSS / CS / VM (D-PT) Max.1 DLC-8 KX-TDA3172 - 8 Port D-PT Card - D-PT / DSS / CS / VM (D-PT) Max.2 SLC-4 KX-TDA3173 - 4 Port SLT Card - 4 DTMF receiver - + 40V Line feed Max.1 SLC-8 KX-TDA3174 - 8 Port SLT Card - 8 DTMF receiver - + 40V Line feed Max.2 Note : Optional DHLC card is not provided. Note : All cards for TDA30 are NOT hot swappable

  9. System Hardware -3 Optional Cards-1 MSG-2 KX-TDA3191 - 2 Port Message/DISA Card - OGM Max.15min, 32messages Max.2 DPH-4 KX-TDA3161 - 4 Port Doorphone Card - Doorphone for T30865 - 4 Door Opener - 4 External Relay Output (Ver.2.0) - 4 External Sensor Input (Ver.2.0) Max.1 DPH-2 KX-TDA3162 - 2 Port Doorphone Card - Doorphone for Germany Type - 2 Door Opener - 4 External Relay Output (Ver.2.0) - 4 External Sensor Input (Ver.2.0) Max.1 Echo-8 KX-TDA3166 - 8 Port Echo Cancelling Card Max.1 Note : All cards for TDA30 are NOT hot swappable

  10. System Hardware -4 Optional Cards-2 Ext. Caller ID KX-TDA3168 - Caller ID Signal Generation Card - Max. 8 SLT (4ports x 2resources) - FSK Signal V23/Bell202 - 1st Bell -- Caller ID -- 2nd Bell Max.1 RMT KX-TDA3196 - Analog Modem Card. - V.90 Support. Max.1 Note : All cards for TDA30 are NOT hot swappable Additional AC power adapter (it is the same as packed adapter) KX-A236 When the total number of PT (*) exceeds 4, or the total number of CS exceeds 4, an additional AC power adapter is required. * defined as A-PT, T72xx, T74xx, T75xx (except T7560/T7565) and all DSS Consoles. When a BRI card is configured as “internal ISDN” and feeds DC power. Max.1

  11. SLT T76xx & T7560/T7565 Other type DPT/APT and DSS CS TDA0141 ISDN Terminal Total units Second Adapter Power unit 0 0 4 4 1 1 0-24 24 0 0 0 0 No 2 0-24 0 Max 4 Max 4 0 32 No 3 0-24 0 Over 4 0 0 - Yes - Yes 4 0-24 0 0 Over 4 0 5 0-24 0 4 4 1 33 Yes 6 0-24 0 4 3 4 32 No 7 0-24 0 4 3 5 33 Yes 8 0-24 0 3 4 4 32 No 9 0-24 0 3 4 5 33 Yes System Hardware -5 AC Adapter Selection AC Adapter Capability Supplied AC Adapter only: Max. 32 power units + Second Adapter: Max. 96 power units AC Adapter Selection Sample ISDN Terminal: When a BRI card is configured as “internal ISDN” and feeds DC power. TVP connection power unit is “0”

  12. Maximum Cabling Distance ø0.4mm 500m ø0.5mm 720m (CAT5) ø0.6mm 830m - T76xx Series - T7550/T7565 ø0.4mm 140m ø0.5mm 229m (CAT5) ø0.6mm 360m - Other D-PT/A-PT - All DSS ø0.4mm 698m ø0.5mm 1128m (CAT5) ø0.6mm 1798m SLT ø0.4mm 227m ø0.5mm 347m (CAT5) ø0.6mm 500m TDA0141(CS) 5m USB Point to Point 1000m (CAT5) Point to Multi-Point 150m (CAT5) ISDN Terminal ISDN S0 Bus 5m USB Terminal USB USB Terminal

  13. LPR Card TDA30 TDA100/200 LPR Card TDA30 TDA100/200 LCOT-4 TDA3180 - DHLC-8 - TDA0170 LCOT-8 - TDA0180 DLC-4 TDA3171 - LCOT-16 - TDA0181 DLC-8 TDA3172 TDA0171 E&M - TDA0184 DLC-16 - TDA0172 E1 - TDA0188 SLC-4 TDA3174 - CID/PAY8 - TDA0189 SLC-8 TDA3174 TDA0173 CID (CO) TDA3193 TDA0193 SLC-16 - TDA0174 BRI-2 TDA3280 - MSLC-16 - TDA0175 BRI-4 - TDA0284 CS I/F - TDA0144/0143 BRI-8 - TDA0288 PRI-30 - TDA0290 IPGW-4 TDA3480 TDA0480 Card TDA30 TDA100/200 Card TDA30 TDA100/200 OPB-3 - TDA0190 RTM TDA3196 TDA0196 DPH-4 TDA3161 TDA0161 MSG TDA3191 TDA0191 DPH-2 TDA3162 TDA0162 Ext. CID TDA3168 - Echo TDA3166 TDA0166 CTI-LINK - TDA0410 System Comparison TDA30 & TDA100/200 Extension Trunk Other

  14. - Doorphone (Max.1) - MSG (Max.2) - Ext.Caller ID (Max.1) - Echo chancel (Max.1) - DLC-4 (Max.1) - SLC-4 (Max.1) - BRI-2 (Max.3) - LCOT-4 (Max.3) - DLC-8 (Max.2) - SLC-8 (Max.2) - IPGW-4 (Max.1) SD Card Holder USB EPG RS232C MOH DHLC-4 (Fixed) Clear S/W Reset S/W Power S/W Battery Backup connector for KX-A228 AC Power Adapter Additional AC Power Adapter KX-A236 View Front S-11 S-4 S-7 S-10 S-3 S-6 S-9 S-2 S-5 S-8 S-1 Rear Battery charging Current :200mA

  15. Slot CO Trunk CO-1 CO-2 CO/Ext IPGW BRI Analog Total 01 - - - - 0 0 0 02 BRI-2 - - - 4 0 4 03 BRI-2 BRI-2 - - 8 0 8 04 BRI-2 BRI-2 BRI-2 - 12 0 12 05 LCOT-4 - - - 0 4 4 06 LCOT-4 LCOT-4 - - 0 8 8 07 LCOT-4 LCOT-4 LCOT-4 - 4 12 12 08 BRI-2 LCOT-4 - - 4 4 8 09 BRI-2 BRI-2 LCOT-4 - 8 4 12 11 4 4 4 YES 12 16 10 BRI-2 LCOT-4 LCOT-4 - 4 8 12 CO Line Configuration CO Trunk Without IPGW card CO Trunk With IPGW card

  16. With DXDP Slot Without DXDP Built-in Line/Ext. Ext.-1 Ext.-2 SLT D-PT SLT D-PT 01 4S/4D - - - 4 4 4 8 02 4S/4D SLC(S4) - - 8 4 8 8 03 4S/4D SLC(S4) SLC(S8) - 16 4 16 8 04 4S/4D SLC(S4) DLC(D8) - 8 12 8 20 05 4S/4D SLC(S4) SLC(S8) SLC(S8) 24 4 24 4 06 4S/4D SLC(S4) SLC(S8) DLC(D8) 16 12 16 12 07 4S/4D SLC(S4) DLC(D8) DLC(D8) 8 20 8 20 4S/4D DLC(D4) - - 4 8 4 16 08 4S/4D DLC(D4) SLC(S8) - 12 8 12 16 09 4S/4D DLC(D4) DLC(D8) - 4 16 4 24 10 4S/4D DLC(D4) SLC(S8) SLC(S8) 20 8 20 8 11 4S/4D DLC(D4) SLC(S8) DLC(D8) 12 16 12 16 12 4S/4D DLC(D4) DLC(D8) DLC(D8) 4 24 4 24 13 Extension Configuration Max. Extensions : 28

  17. DXDP-Master DXDP-Slave 2 Wires 2 Wires XDP DXDP-Slave 4 Wires 4 Wires DXDP-Master 4 Wires 2 Wires 2 Wires 2 Wires Digital Extra Device Port (Digital XDP)-1 DXDP is available from first release, version 1.0 - DPT on DPT without additional HW or SW - Easy installation for additional Extensions - One DHLC port can be used for three telephones (2 x D-PT + 1 x SLT) - One DLC port can be used for two telephones (2 x D-PT)

  18. DXDP-Master DXDP-Master XDP DXDP-Slave DXDP-Slave XDP Digital Extra Device Port (Digital XDP)-2 Connection & Extension Number Assignment Oh! Easy DXDP-Slave

  19. ø0.4mm Max. 500m ø0.5mm Max. 720m (CAT5) ø0.6mm Max. 830m ø0.4mm Max.40m ø0.5mm Max.50m (CAT5) ø0.6mm Max.60m DXDP-Slave DXDP-Master Telephone Master Slave Can be used - T7625 - T7630 - T7633 - T7636 - T7665 - T7625 - T7630 - T7633 - T7636 - T7665 Can not be used • - A-PT • - T72xx • - T74xx • - T75xx • DSS • - A-PT • - T72xx • - T74xx • - T75xx • DSS • CS • TVP Digital Extra Device Port (Digital XDP)-3 Condition-1 Condition-2 Condition-3 - OHCA function can not be used - T7601 (USB) can not be used (PC Phone / PC Console / PC Programming) Condition-4 (Parallel Connection) Sorry “NO”

  20. ø0.4mm 222m ø0.5mm 347m (CAT5) ø0.6mm 500m Max.8 CS : Two AC adapters New DECT- CS (KX-TDA0141)-1 - Specific CS I/F card is not needed. - A port on DHLC or DLC4/8 can used as the interface of KX-TDA0141. - Two Voice Path per a CS. - Functionality : The same as TDA0142 Max.4 CS : One AC adapter - CS Port assignment is not needed The TDA30 automatically detects the connected CS.

  21. 1- Set a CS port to “OUS” 3- Select “PDCSDECT” 4- Click “Detail” New DECT- CS (KX-TDA0141) -2 How to update the CS software 2- Go to “SD Card File View and Load” 5- Take the same procedure as TDA100/200

  22. Caller ID for SLT (KX-TDA3168) -1 With the addition of the KX-TDA3168 the TDA30 provides CLIP information for single line telephones. Caller ID data KX-TDA3168 Resource assignment The KX-TDA3168 has 2 resources (4ports/resource=Total 8SLT), the resources assignment for SLT extension card is needed. DHLC SLC-4 TDA3168 SLC-8-1 1-4 SLC-8-1 5-8 SLC-8-2 1-4 2 resources SLC-8-2 5-8

  23. Parallel mode Ext.201 Ext.201 XDP mode Ext.201 Ext.205 1st Call 2nd Call Caller ID for SLT (KX-TDA3168) -2 Enable/Disable We enable/disable port by port. Timer=0: 1st call Ring  1st caller disconnects  2nd call Ring Timer=5: 1st call Ring  1st caller disconnects wait 5sec 2nd call Ring

  24. New IPGW Card (KX-TDA3480) - 4ch IPGW Card - G729a/G723.1/G711 - T.38 (FAX) mode is not supported (FAX = G711) - Physical i/f: 10/100 Base-T - Web programming (English) - Interoperability with TDA0480: Incoming call, Outgoing call and CLIP only. - Interoperability with another manufacturers : Not guaranteed.

  25. Ext.30 (Ring) Ext.20 Group CW w/o Tone = Enable (Ring After Call) Ext.30 (Ring) Ext.20 Busy Improved ICD-Group function TDA100/200 Ver.1.0 (1.006) External Call Ring After Call = Enable Only one option The call arrives at Ext.20. Busy TDA30 Ver 1.0 External Call Tow options The call arrives at Ext.20. The call is queued. This improved function is supported from TDA100/200 Ver.1.1

  26. KX-TDA100/200 KX-TDA30 Features Not Supported by KX-TDA30 - The KX-TDA30 does not support the MSLC Functionality Therefore it will not support the KX-T7710, with its 90V neon message waiting light. - E1 / E&M / PRI / CTI-link card are not supported by the TDA30. - Pay tone detection is not supported by the TDA30.

  27. PBX Features (Software) - The TDA30 features are the same as TDA100/200 features. Optional Card Software - All Optional Cards (Except IPGW, CS) are controlled by MPR. PC Programming Software - Almost the same as TDA100/200 PC programming software. Maintenance Commands -The TDA30 PBX maintenance commands are the same as TDA100/200 PBX trace data capture function T-G 101 Volume level adjustment T-G 103 Advanced Ring setting T-G 105 Dial Tone level adjustment T-G 106 D-PT Gain adjustment T-G 108

  28. Language data We can use the TDA100/200 language data. Optional Card data System data TDA0141 program System program PBX SD card data