Implant Surface Adhesion Analyzer

Implant Surface Adhesion Analyzer. Group Members: Brad Galpern Katie Knudson Kory Nelson Academic Advisor: Sean Kohles, PhD Industry Sponsor: 3I. Gap. Surface roughness of implanted materials affect adhesion quality Macro scale testing borrowed from other industries.

amy
Télécharger la présentation

Implant Surface Adhesion Analyzer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Implant Surface Adhesion Analyzer Group Members: Brad Galpern Katie Knudson Kory Nelson Academic Advisor: Sean Kohles, PhD Industry Sponsor: 3I

  2. Gap • Surface roughness of implanted materials affect adhesion quality • Macro scale testing borrowed from other industries http://www.instron.us

  3. Objective • Design an apparatus to investigate the effects of various surface topographies on the adhesion of implants to bio-materials. • Simulate mode 1 fracture • Apply, measure and correlate force and displacement data • Scaleable IMMEDIATE OCCLUSAL LOADING™ (IOL™) OF DENTAL IMPLANTS: Predictable Results Through DIEM™ GuidelinesRichard J. Lazzara, DMD, MScD

  4. Objective • Force vs Roughness crack length • Force vs Linear crack length Images courtesy of Dr. Kohles

  5. Frame 6061 Al Pyramid design - strength, visual access Secure specimen jig Houses motor and laser Electric Motor 3V 1300 to 1 Gear reduction Design Components

  6. Design Components • Specimen Jig • 6061 Al • Simulate mode 1 fracture • House test specimens • Houses other components • Sensor Array • Input light and voltage, output resistance • Scaleable

  7. Design Components • Laser • Powerful and concentrated light • Fanned horizontally • Drastic contrast to ambient light • Force Sensor • Compression sensor adapted • Input voltage and force, output resistance

  8. Design Components • Test Specimens • Machined plastic bars • Simulated bio materials • Varying mechanical properties

  9. Testing

  10. Results

  11. Results

  12. Conclusion • All design components are scaleable • Proof of concept achieved