CPR2 Optical Cables

CPR2 Optical Cables. …taking optical signals from edge of CPR/crack detectors to PMT boxes mounted on back of wedges. Joey Huston Michigan State University. Optical cables. Optical cables ~3-5m long take optical signals to PMT boxes mounted on back of wedges

anahid
Télécharger la présentation

CPR2 Optical Cables

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CPR2 Optical Cables …taking optical signals from edge of CPR/crack detectors to PMT boxes mounted on back of wedges Joey Huston Michigan State University

  2. Optical cables • Optical cables ~3-5m long take optical signals to PMT boxes mounted on back of wedges • diameter of clear fiber steps up to 1.1 mm in order to reduce alignment issues

  3. Routing • Clear fibers are routed into 4 connectors of 16 channels each • connector D has 6 fibers from CPR and 10 from crack detector

  4. Light-tighting • Black plastic covering for optical cable • Sliding plastic shroud for connector region

  5. Clear fiber attentuation length • Clear fiber tests conducted at Rockefeller • Attenuation length best fitted to 2-components • PolyHiTech and Kuraray give similar results • PolyHiTech used for cables • 1000 m of Kuraray purchased for spares

  6. Optical cable installation issues • Main Installation Issue for Preshower/Crack. • Length of cables is at best an educated guess. Need full scaffold and PMT boxes installed to measure best lengths. • extra 50 cm of cable causes 10% loss of light yield, and is a good place to cause fiber damage. • PMT box placement changes depending on wedge, and complete plan changed 4 times in last long access. • Plan is to make 50% of the optical cables before shutdown with educated guess, then after first week of shutdown make the rest (takes about 1.5 weeks per arch).

  7. Determining cable lengths Determine step-by-step the additional lengths to add to these straight-line paths for optical cables. Approximate distances to add to the clear fiber lengths (for normal wedges) 110 mm -- middle of wedge to farthest CPR connector 205 mm=8” -- distance across side window on wedge 915 mm=36” -- horizontal distance across wedge to PMT box 305 mm=12” -- vertical distance to PMT box 305 mm=12” -- lateral distance to PMT box 150 mm -- safety margin (?)

  8. Step 2: The window height is known to be 8”, and the cables must enter the back of the wedge from the farther point on the window. Assume a straight line from the middle point on bottom of window to middle point on top of window. 8” = 205 mm

  9. Signal and HV cables Electronics crate Optical cables PMT access Black LED fibers for EM Cal Step 3: 3’ from entry point at window to middle of plate holding PMT boxes. 3’ = 915 mm 3’ to middle

  10. Step 4: Plate that box sits on could be as high as 6”. Top cable for the box is about 6” high. So add about 12”=305mm for a vertical rise from the base of wedge to the PMT box. Step 5: Optical cable entry point in the window will likely not line up with PMT box hole. Assume a 12”=305mm travel across wedge for this.

  11. Tight spots Tight fit in last long access! Scraped sides of connector on 1 arch, fine on the other arch. MSU has since trimmed connector by 1.5 mm.

  12. 4 PMT boxes mounted on sides of monkey bars 6 PMT boxes mounted on “normal” wedges 2 PMT boxes mounted on inside of cradle