Low cost on-line non-invasive sewer flow monitoring

Low cost on-line non-invasive sewer flow monitoring Andy Nichols, Kirill Horoshenkov , Simon Tait , Simon Shepherd and Yanmin Zhang a.nichols2@bradford.ac.uk. Collaborators : Open University Cardiff University Stanford University Yorkshire Water Services Funding :

april
Télécharger la présentation

Low cost on-line non-invasive sewer flow monitoring

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Low cost on-line non-invasive sewer flow monitoring Andy Nichols, Kirill Horoshenkov, Simon Tait, Simon Shepherd and Yanmin Zhang a.nichols2@bradford.ac.uk • Collaborators: • Open University • Cardiff University • Stanford University • Yorkshire Water Services • Funding: • Yorkshire Water Services • EPSRC grant EP/G015341/1

  2. Andy Nichols | a.nichols2@brad.ac.uk ‘Traditional’ flow monitor (submerged acoustic Doppler) • Operates from within the flow. • Estimates flow depth and velocity • Main disadvantages: • Permanent obstruction to the flow • Accumulation of debris – maintenance requirements • Backscatter approach – power requirements

  3. Andy Nichols | a.nichols2@brad.ac.uk Airborne Doppler flow monitor • Operates from above the flow • Estimates flow depth and velocity • Main advantages: • Minimal obstruction to the flow – only when surcharged • Minimal accumulation of debris – minimal maintenance • Main disadvantages: • Backscatter approach – power requirements • Assumption of surface pattern behaviour • The free surface pattern does not simply travel along like a car on a motorway. • Features may appear, fluctuate, oscillate, merge, separate, dissipate. • The vertical motion can cause a Doppler shift comparable to that of the horizontal motion. • Above all, the behaviour is not understood, so precisely what the device measures cannot be defined. BUT: Perhaps the surface fluctuation behaviour can be used….

  4. Andy Nichols | a.nichols2@brad.ac.uk Measuring temporal surface fluctuations at a point – forward scatter 1. An ultrasonic beam is fired toward the dynamic surface. 2. The signal is reflected to a receiver. 3. The phase of the received signal fluctuates according to the surface. Wave probe 2 1 3 3

  5. Andy Nichols | a.nichols2@brad.ac.uk Tracking surface fluctuations • Multiple receivers allow a fluctuation time series to be recorded from multiple known locations on the free surface. • Time series from nearby points can be quite different (hence the issues with the Doppler approach), • BUT similar enough to estimate the temporal lag (by cross-correlation), and hence the surface velocity. 2 wave series separated by a small distance

  6. Andy Nichols | a.nichols2@brad.ac.uk Field prototype development

  7. Andy Nichols | a.nichols2@brad.ac.uk But can we do more? - Measuring the spatial evolution of the surface pattern So we can measure advection velocity between pairs of reflection points, and can use a time-of-flight technique to measure flow depth, and hence estimate flow rate. BUT We can also cross correlate between pairs of reflection points to obtain a spatial correlation function This describes the nature of the free surface pattern and relates to the underlying turbulence, which is governed by the flow conditions, allowing a number of empirical relationships to be drawn.

  8. Andy Nichols | a.nichols2@brad.ac.uk Conclusions • Forward scatter airborne acoustics allow unambiguous measurement of flow surface behaviour. • Tracking the free surface pattern in this manner allows velocity estimation. • Time-of-flight measurements can provide depth data, in order to estimate flow rate. • Further information regarding the flow conditions is encoded in the free surface pattern.

  9. Thank You Low cost on-line non-invasive sewer flow monitoring Andy Nichols, Kirill Horoshenkov, Simon Tait, Simon Shepherd and Yanmin Zhang a.nichols2@bradford.ac.uk