An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PCSM PlansCommon Mistakes, Notes, etc. Presented by Aneca Y. Crews PADEP-SERO

  2. Agenda • Common Mistakes • PCSM Plan Notes • Stormwater BMP Information Chart 5B

  3. Common Mistakes

  4. Common Mistakes • Insufficient infiltration documentation • No testing performed, not enough tests performed, test field logs not provided, • Unacceptable testing techniques utilized • Testing not performed at location(s) or elevation(s) of proposed system(s) • Avoid using the “perc” test • Use infiltration test that determines hydraulic conductivity. • No geotechnical information provided • Reduction factors not used

  5. Common Mistakes • Runoff from impervious surfaces are conveyed directly to infiltration systems • Pretreatment should be provided for stormwater runoff prior to entering a subsurface infiltration system. • Clogging from sediment and debris→Failure • Off-Site Discharges • Discharges are not going to well defined drainage features • Not identified in the Notice Of Intent (NOI)

  6. Off site discharge (Section C) Becoming a common problem.

  7. Easements (Legal Issue) Fact Sheet Follow bulleted items Analysis of discharge Discharges to non-surfaces waters need to demonstrate that the discharge will not cause erosion or damage Discharge to Non-Surface Water: Level Spreader Conveyance Profile View N.T.S. Suitable rigid measures and protective geofabric (TRM)- min. 3 ft. or as needed. X Outflow Y Inflow Undisturbed Ground Plunge Pool h Level Spreader Optional Drain. 2” ductile iron Driven horizontally Off Site Discharges

  8. Common Mistake • Modified Rational Method used for Runoff Volume calculations. • National Resources Conservation Service (NRCS) methods must be used for Volume calculations. • The Modified Rational Method is not acceptable. • Potential Pollutants/Contamination • Not identified on the NOI • Contamination documentation not provided • For Site Specific Standard or Non-residential Statewide Health Standards proper Erosion and sediment (E&S) not utilized

  9. Common Mistake • Not requesting a Pre-application meeting • Projects of complex nature or varying from PA Stormwater Best Management Practices (BMP) Manual should request pre-application meeting. • Conservation District and/or DEP • Inconsistencies between plans, details, and calculations • Inconsistent submittals will cause confusion and increase review time.

  10. Common Mistakes • Structural/Non-Structural (NS) BMP Volume Credit • Volume reduction credit can only be taken for runoff reaching the proposed BMP during the 2-yr 24 hour storm or a smaller event • No more than 25% of required volume reduction achieved through NS • Can not claim volume credits on Worksheet 5 for extended detention

  11. Non Structural Credits from WS 3 Other credits for Non-Struct. BMPs are listed in Chapter 8 of BMP Manual such as: BMP 5.4.3 Protect/Utilize Natural Flow Paths Credit = ¼” x Area BMP 5.6.3 (pt. 2) Revegetate/Reforest Credit = 6 cf/tree Deciduous or Credit = 10 cf/tree Evergreen

  12. Checklist: Criteria and Credits for Non Structural BMPs Checklists are found in Ch. 8 (Section 8.8) Checklists are required when seeking NS Volume Credit To receive credit, each box should be checked.

  13. NPDES Application (rev. 12/2009)

  14. Updated Worksheet 5 NEW OLD

  15. Worksheets • Worksheets 1 thru 5 and 10, should be completed for each point of interest.

  16. Nitrates Compliance Worksheet 10 can be misleading. Only use when can meet Volume Control Guidance (CG-1). If not, complete WS 11 to 13 Should control runoff from at least 90% of the disturbed area. If not, also need WS 12 & 13. WS 12 – Pollutant Loading WS 13 – Pollutant Reduction

  17. Standard Notes

  18. Standard Notes • Ownership, Operations, and Maintenance Procedures(Must be included on drawings) • Applicant or entity (association, company, agency, etc.) listed as responsible party • Provide Quality Control of Materials. As with all BMPs, the final product is only as good as the materials and workmanship that went into it. The designer is encouraged to review and approve materials and workmanship, especially as related to aggregates, geotextiles, soil and topsoil, and vegetative materials.

  19. Standard Notes • Do not compact soil infiltration beds during construction. Prohibit all heavy equipment from the infiltration area and minimize all other traffic. Equipment should be limited to vehicles that will cause the least compaction, such as tracked vehicles. • Protect the infiltration area from sediment until the surrounding site is completely stabilized. Methods to prevent sediment from washing into BMPs should be clearly shown on plans. Where geo-textile is used as a bed bottom liner, this should be extended several feet beyond the bed and folded over the edge to protect from sediment wash into the bed during construction, and then trimmed. Runoff from construction areas should never be allowed to drain to infiltration BMPs. This can usually be accomplished by diversion berms and immediate vegetative stabilization. • If an infiltration area is also to be utilized as a temporary sediment basin, excavation should be limited to within 1 foot of the final bottom invert of the infiltration BMP to prevent clogging and compacting the soil horizon, and final grade removed when the contributing site is fully stabilized. All infiltration BMPs should be finalized at the end of the construction process, when upstream soil areas have a dense vegetative cover.

  20. PCSM Notes & Permit Special Conditions 1. A Notice of Termination (NOT) will be required to be submitted following approval of the final as-built plans. Prior to accepting the NOT, the Department and/or Conservation District will perform final inspection to ensure site stabilization and verify adequate installation and function of stomwater best management practices (BMPs) 2. As-built plans for the stomwater BMPs for each project phase shall be provided within six months following the completion of each phase. The as-built plans shall be signed and sealed by a PA Registered Professional Engineer. 3. The Permittee shall provide engineering construction oversight for the proposed stormwater BMPs. Additional soil testing may be required prior to the installation of infiltration BMPs to ensure proper location and function. 4. The permittee shall provide for engineering construction oversight for the proposed stormwater best management practices (BMPs). A licensed professional engineer knowledgeable in the design and construction of stormwater BMPs, preferably the design engineer, shall conduct oversight.

  21. STORMWATER BMP INFORMATION CHART 5B

  22. Stormwater BMP Info Chart 5.B • Why is this needed? • A condensing of the calculations for proposed BMP’s • Highlights common mistakes • Supporting calculation/documentation should be included in Stormwater Report

  23. Stormwater BMP Info Chart 5.B

  24. Infiltration Information

  25. Stormwater BMP Info Chart 5.B

  26. Drainage Information

  27. Stormwater BMP Info Chart 5.B

  28. BMP Information

  29. Stormwater BMP Info Chart 5.B • Foot notes reference Appendix C of the PA BMP Manual under Site conditions and constraints and Design consideration

  30. 2-year 24-hour storm only Similar to WS 4 but limited to drainage to indiv. BMP (Post Dev)

  31. Section C – E&S and PCSM • Stormwater BMP Chart 5B should match the summary table in section C.2 of the NPDES application. Both should match Stormwater Report

  32. Submit a complete application Follow the application instructions and BMP Manual. Provide volume control for difference in 2-year w/o any voodoo hydrology. Utilize Worksheets and supporting checklists. (for each point of interest) Request a preapplication meeting with CD and/or DEP. Communicate with reviewer to better understand outstanding issues and find viable solution How to expedite the review

  33. Timeframes* for NPDES Approval: • Varies among by region and county. • PAG-2: • 45 to 100 days • Individual Permit: • 3 to 6 months • Add another 60 days if a public hearing is required. • Each deficiency letter allows 60 days to provide a complete response * Timeframes above assume a reasonably quick turnaround by designers to comments.

  34. Stormwater BMP Highlights • Chapter 3- Principles & Control Guidance • Chapter 5- Non-structural BMPs • Chapter 6- Structural BMPs • Chapter 8- Methods & Worksheets • Appendix C – Site Evaluation & Soil testing • NOI checklist & instruction

  35. FIN Questions? Contact Info: Aneca Y. Crews Stormwater Section PA DEP - SERO 484-250-5129 acrews@state.pa.us

  36. Checklists • Criteria and Credits for Non-Structural BMPs. • Plan requirements • Required for most submittals requesting NS Credits.

More Related