Conventional Energy Systems. High Pressure Steam 97 Units. 117 Units. 35 Units. STEAM TURBINE (Eff. = 42%). DISTRIBUTION SYSTEM (Eff. = 92%). BOILER (Efficiency = 83%). 38 Units. 41 Units. GENERATOR (Eff. = 94%). CONDENSER. 175 Fuel Source units yields: 35 Units of Electricity and

Télécharger la présentation

Conventional Energy Systems

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Conventional Energy Systems High Pressure Steam 97 Units 117Units 35Units STEAM TURBINE(Eff. = 42%) DISTRIBUTION SYSTEM(Eff. = 92%) BOILER(Efficiency = 83%) 38 Units 41 Units GENERATOR(Eff. = 94%) CONDENSER • 175 Fuel Source units yields: • 35 Units of Electricity and • 45 Units of Thermal Energy 58Units Heat to Campus45 Units BOILER(Efficiency = 80%) Overall Efficiency: 45%

  2. Cogeneration System 35Units 100Units 38 Units Combustion Gas Turbine(Efficiency = 38%) GENERATOR(Eff. = 92%) • 100 Fuel Source units yields: • 35 units of electricity and • 45 units of thermal energy HEAT RECOVERY STEAM GENERATOR Heat to Campus45 Units Overall Efficiency: 80%