Westminster, Colorado June 12, 2012

2012 API Cooperative Testing Preliminary Report on Compressive Strength. Westminster, Colorado June 12, 2012. 2012 Protocol. Test Protocol in 2012 matched previous years: Cubes: 100F 8 hours 140F 8 hours 100F 24 hours UCA: 100F 8 hours 100F 24 hours Time to 50 and 500 psi

Télécharger la présentation

Westminster, Colorado June 12, 2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2012 API Cooperative Testing Preliminary Report on Compressive Strength Westminster, Colorado June 12, 2012

  2. 2012 Protocol • Test Protocol in 2012 matched previous years: • Cubes: • 100F 8 hours • 140F 8 hours • 100F 24 hours • UCA: • 100F 8 hours • 100F 24 hours • Time to 50 and 500 psi • Changes to protocol in 2012 • As in 2010, eliminated 20 minute pre-conditioning requirement • Eliminated the requirement to calculate cube density • Continue to request pictures of load frames utilized • Further analysis to be included in Final CS Report in New Orleans • CS results tied to load frame group: Manual vs Digital • Evaluation of UCA Transit Time • Service Companies and other vs. Cement Plants • Load frame verification using low strength Burst Disks at known failure values

  3. 2012 Preliminary Strength Data

  4. Compressive Strength Comparison 2010 vs. 2012 (preliminary data)

  5. UCA Time to 50 & 500 psi(preliminary data)

  6. 2012 UCA and Cube CSsorted by value (preliminary data)

  7. 2000 to 2012 UCA vs Cubes Average Compressive Strength (preliminary data)

  8. CV Comparison 2000 to 2012 (preliminary data)

  9. 2012 Preliminary Conclusions • High variability continues with 8 hr cube test. • Initial CVs for all test categories continues to creep up. • Historical relationships between cubes and UCA holds true. • Good response to request for load frame pictures will permit further analysis. • Let’s see what full data set reveals after more in depth analysis.

  10. Thank you! Comments and Questions?