Data Quality – Preliminary Results from visit from UW Researchers

Data Quality – Preliminary Results from visit from UW Researchers. Kristin Tufte, Robert L. Bertini, Yinhai Wang, Patikhom (Num) Cheevarunothai. Data Quality. Results from UW visit… 3 stations visited I-5 NB Kruse Way/217 I-5 NB Multnomah I-5 NB Bertha/Terwilliger

banyan
Télécharger la présentation

Data Quality – Preliminary Results from visit from UW Researchers

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Data Quality – Preliminary Results from visit from UW Researchers Kristin Tufte, Robert L. Bertini, Yinhai Wang, Patikhom (Num) Cheevarunothai

  2. Data Quality • Results from UW visit… • 3 stations visited • I-5 NB Kruse Way/217 • I-5 NB Multnomah • I-5 NB Bertha/Terwilliger • Investigated loop detector calibration and controller configuration using ALEDA

  3. Station Selection • Stations for study were selected based on several criteria • Observed anomalies in PORTAL plots • Unusually low occupancy (Terwilliger/Bertha) • Low overnight speeds (Kruse Way) • High rate of failure of TTI Maximum Occupancy Test (occupancy > 95%) (Multnomah) • Unusual flow/occupancy ratio • High rate of failure of TTI Maximum Speed test (speed > 100 mph) • High rate of failure of TTI Maximum Volume test (20-second volume > 17)

  4. I-5 NB OR 217/Kruse Way (mp 292.18) • Perceived Problem: Low nighttime speeds are a serious problem at this detector. Daytime speeds look reasonable. Lane 3 shows similar issues, lane 1 shows fewer issues with low nighttime speeds. • Fixes Applied: ALEDA used to tune loop detector sensitivity • Results: slight improvement in overnight speed – issues still not resolved • Cabinet Observations: Lane 1 (lane 3 in field) has different type of controller; suspect controller is thie issue for lanes 2 and 3

  5. I-5 NB OR 217/Kruse Way (mp 292.18) Sept 18, 2007 Lane 2 Sept 18, 2007 Lane 3 Sept 18, 2007 Lane 1 Sept 24, 2007 Lane 1 Sept 24, 2007 Lane 2 Sept 24, 2007 Lane 3

  6. I-5 NB Multnomah • Perceived Problems: • Lanes 1 and 3 exhibited a high number of readings with occupancy > 95% • Lanes 1 and 3 behaved very differently from lane 2. • Low overnight speeds • Cabinet Comments: cabinet was in poor shape, ALEDA could not be used due • Fixes Applied: Observed that a button that was pushed in (out?) on lane 2 was out (in?) on lanes 1 and 3. Pushed button in (out?) on lanes 1 and 3 • Results: Significant improvement in speed and occupancy measurements for lanes 1 and 3

  7. I-5 NB Multnomah (mp 296.6) (speed) Sept 19, 2007 Lane 2 Sept 19, 2007 Lane 3 Sept 19, 2007 Lane 1 Sept 21, 2007 Lane 1 Sept 21, 2007 Lane 2 Sept 21, 2007 Lane 3

  8. I-5 NB Multnomah (mp 296.6) (occupancy) Sept 19, 2007 Lane 2 Sept 19, 2007 Lane 3 Sept 19, 2007 Lane 1 Sept 21, 2007 Lane 1 Sept 21, 2007 Lane 2 Sept 21, 2007 Lane 3

  9. I-5 NB Bertha/Terwilliger (mp 297.33) • Perceived Problem: Unusually low occupancy • Fixes Applied: • Observed controllers were set to pulse mode, changed controller setting to medium presence mode • Used ALEDA to calibrate loop detector sensitivity • Results: significant improvement in occupancy measurements

  10. I-5 NB Bertha/Terwilliger Sept 19, 2007 - Speed All Lanes Sept 19, 2007 - Occupancy All Lanes Sept 20, 2007 - Speed All Lanes Sept 20, 2007 - Occupancy All Lanes