An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TPC ExBdistortion at LHC-ALICE experiment Yasuto Hori for the ALICE-TPC collaboration Center for Nuclear Study, University of Tokyo

  2. Outline • Introduction: ALICE-TPC and ExB distortion • Calculation technique of ExB distortion • Many kinds of ExBdistortion • ExB Twist distortion • Summary and Outlook

  3. Overview of ALICE-TPC gy B field UV Laser tracks in TPC drift volume z gx E field IP beam 100kV A side ROC C side (muon-side) ROC • Main central tracking device • diameter x length = 5 m x 5 m,|h| < 0.9, 2pazimuthal coverage • Max drift length ~ 2.5 m, Central electrode ~100kV  E ~ 400V/cm • gas Ne-CO2-N2(85.7%:9.5%:4.8%) •  low diffusion & high drift velocity(drift time 92msec), • but strong temperature dependent drift velocity • temperature stability & homogenity < 0.1K  cooling system and P,T monitor • UV laser system used for drift velocity, ExB, alignment

  4. ExBdistortion in ALICE-TPC • Electrons are drifted at the E field direction if ExB is zero. • If ExB is non-zero  Space point distortion on the Pad plane • (or x-y, r- phi) occurs • This distortion may degrade DCA-to-Vertex distribution, • DCA-btw-2tracks distribution, • ITS-TPC matching efficiency,.. Gating Grid wire Track E &B field Drift electrons Distorted drift electron Pad plane

  5. Calculation technique via Langevin equation • Langevin eq. which describes this distortion can be decomposed • into E field part and B field part if Ez≫ Er,Ef& Bz≫ Br,Bf • We have to know parameter T1, T2 of Ne:CO2:N2 Next slide Decompose + wt tensor Steady-state langevineq Space point distortion E field distortion B field distortion

  6. T1, T2 extraction via Laser track distortion with Gating Grid Voltage (GGV) Scan Procedure Calibrate Voltage at GG plane by measuring C1&C0 using B=0 laser tracks ( C1&C0 must be 0 & 1 at B=0 ) 2. Measure change of track distortion with GGV scan at B=5kGaus 3. Compare with calculation using T1 and T2  T1 = 1.0 +- 0.1, T2=1.0 +-0.3 is obtained! T1 = 1.0 T2 = 1.0 GGV= 10 V drf [cm] Distortion change [cm] Z [cm] Radi [cm] Zigzag pattern of Real data is from Pad geometry Radi [cm]

  7. ExBdistortion Sources and Models • B field non-uniformity •  B field is measured, non-zero Br, Bf, corrected to ~0.3mm • Twist between E and B field axis •  TPC is tilted from the B field axis • E field distortion by misalignment of TPC components • (field cage, each rod, ROC, central electrode ) • GGV Error from normal setting • E field distortion because of space charge drf [mm] dr [mm] R [cm] Z [cm] gY [cm] gX [cm] B field TPC  Next 3 slides E field

  8. Twist between E and B axis • space point distortion∝ drift length and angle between E and B axis • track distortion is similar to translation, but A side track is • translated to the opposite direction of C side track translation Value to be measured dr [cm] Zdrift = 250 cm Z[cm] R [cm] gY[cm] gX[cm] Zdrift = 250 cm drf[cm] gY[cm] R [cm] Z[cm] gX[cm]

  9. A/C vertex shift due to ExB Twist • By ExB Twist Distortion, x-y position of vertex reconstructed by only • A side tracks is shifted from that of only C side tracks Distorted A track Original track Distorted C track fast simulation full simulation (small statistics) TPC pad plane A/C Vertex shift Inner wall Outer wall A/C vertex shift is almost proportional to Twist angle !! 

  10. Twist angles extraction and verification at p+p collision data B positive data B negative data A Vertex C Vertex Primary Vertex A vertex C vertex C vertex A vertex • A/C vertex shift can be found at pp collision data! • Position of A /C vertex are swapped with B field polarity • Primary vertex (by ITS&TPC all tracks) lays on the middle of the A/C vertex • Twist angles are extracted and verified !!

  11. Summary and Outlook • We construct framework for calculation of ExB distortion • T1&T2 values are extracted by Laser track distortion with GGV scan • List up many kinds of ExB distortion • ExB distortion due to B non-uniformity is already corrected • ExB Twist distortion is measured via A/C vertex shift in p+p collision • real data • measure A/C ROC rotation and translation, which causes A/C vertex • shift • estimate how Rods shift (dominant part of E field distortion) causes • A/C vertex shift • finalize Twist angles • ExB due to E field distortion like Rods shift, … • Space charge at PbPb collision data

  12. - back up -

  13. Misalignment between A side ROC & C side ROC df dY dX

  14. T1, T2 parameters measurement via Laser track distortion with Gating Grid Voltage (GGV) Scan 1 • Change Gating Grid Voltage from normal setting ~ 70Volt • Change “effective” voltage at GG plane • “effective” means that voltage at GG plane depend on GGV setting • itself as well as E field leakage from under GG plane • E field distortion change • ExB space point distortion change, which can be observed by laser tracks • and calculated using T1 and T2 parameters T1 = 1.0 T2 = 1.0 GGV= 10 V drf [cm] Distortion change [cm] Z [cm] Radi [cm] Zigzag pattern of Real data is from Pad geometry Radi [cm]

  15. T1, T2 parameters measurement via Laser track distortion with Gating Grid Voltage (GGV) Scan 2 • “effective” voltage at GG plane can be • calculated by garfield simulation •  GGVeff [V] = 0.9175*GGVsetting[V]+ 3.91 • This can be confirmed by measuring C0 & C1 • value at B=0 data, which must be 1 & 0 •  Reasonable agreement (left chi2 plot) • With above relation, • T1&T2 values are extracted by B=5kGaus laser data •  T1= 1.0 +- 0.1 • T2= 1.0 +- 0.3 • Good agreement with • garfield simulation

  16. With Old corr. With New corr. Sigma of DCA-to-Vertex distribution with 2 sets of correction parameters. Black line is almost consistent to MC 16