An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The SiPM Project Advisors: Dr. Randal Ruchti Barry Baumbaugh Mike McKenna Teacher: Mark Kirzeder Student: Elizabeth Shearer

  2. What is a SiPM? • Silicon Photo Multiplier • A new generation of detection system. • An alternative to traditional PMTs.

  3. SiPMs vs. PMTs • Relatively Large • High voltage • Expensive • Non-recoverable • Inconsistent signals • Affected by B – fields • Not as precise • Slower response time • Small • Low voltage • Relatively low cost • Recoverability • Signal consistency • Unaffected by B –field • Single photon counting ability • Fast response time

  4. SiPM Drawbacks • Optical cross talk • Temperature dependence on dark count • Susceptible to radiation?

  5. Summer 2008 Goals • Construct experimental apparatus • Devise experimental procedure to test SiPM performance • Voltage 69 – 71 Volts • Temperature RT - -35 Co • SiPM size 25 – 100 μm

  6. New Light Tight Box

  7. Cooling Experiment • Thermo Electric Coolers (TECs). Much more difficult than anticipated. • Factors tested • TEC Size • TEC Numbers • TEC arrangements • TEC current and voltage • Heat sink size • Cooling of heat sink, air vs. water

  8. Cooling Chamber Aluminum Heat Sink Ice Water Tube from Chiller TECs Copper SiPM Mount Temperature Probes Nitrogen Gas Tube

  9. Cooling Data – 3rd Try

  10. Cooling Data – 262nd Try

  11. Voltage & Temp Testing • To benchmark the SiPM an LED was pulsed • Data was gathered at varying temperatures and voltages • Thank you Betsy

  12. SiPM @ 69.4 V & 22 Co

  13. SiPM @ 69.4 V & 9 Co

  14. Conclusion • Continue to work on background noise in the system • Investigate SiPM performance below -20 Co • Hook SiPM to a scintillating tile and wave shifting fiber • Hook SiPM to a wave shifting and scintillating fiber