1 / 18

Status Report on f  h g  p + p - 7 g

Status Report on f  h g  p + p - 7 g. Last checks. Raw selected with filfo/par=1: TRK & VTX efficiency, data vs MC MC RAD’04 with T. & M. efficiency curve for clusters K r Mixing angle. TRK efficiency. Cut on clusters E clu <400 MeV

billy
Télécharger la présentation

Status Report on f  h g  p + p - 7 g

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status Report on f  hg  p+p- 7g

  2. Last checks • Raw selected with filfo/par=1: TRK & VTX efficiency, data vs MC • MC RAD’04 with T. & M. efficiency curve for clusters • Kr • Mixing angle

  3. TRK efficiency • Cut on clusters Eclu<400 MeV • 2 prompt neutral clusters qclu>25° & Eclu>50 MeV • |Mgg – Mp|<20 MeV • 2 clusters 0.8<b<0.95 & Eclu>100 MeV • one track qtrk>40° & 200MeV<Ptot<400 MeV  We look if there is a track in a cone of 35° around Pmiss

  4. TRK efficiency + MC + Data Background contamination at level of 1%

  5. TRK efficiency etrk(Data)/etrk(MC) = 0.992±0.003  1%

  6. VTX efficiency • Cut on clusters Eclu<400 MeV • 2 prompt neutral clusters qclu>25° & Eclu>50 MeV • 100MeV < Mgg < 170 MeV • two tracks qtrk>40° & 50MeV<Ptot<400MeV • 850 MeV<Etot<1200MeV  We look for a vertex as a function of the minimum momentum

  7. VTX efficiency + MC + Data Background contamination at level of 1.5%

  8. VTX efficiency evtx(Data)/evtx(MC) = 0.990±0.001  1%

  9. The factor Kr We study Kr vs s for the analyzed runs and take the mean value

  10. The factor Kr Kr =0.940.01  1%

  11. MC RAD’04 • New cluster efficiency curve (T.&M.)

  12. In summer conference we show: where BR” c2 VTX Bg Filfo-EVCL eh/eh' TRK

  13. Now we have: • No changes in systematic evaluation: 4% • Kr correction from 0.95 to 0.94 BR” Kr c2 VTX Bg Filfo-EVCL eh/eh' TRK

  14. Mixing angle • stat. uncertainty: mc extraction of R with Gaussian distribution • syst. unc.: mc extraction of R with flat distribution • th. unc.: difference between angle extractions using different values for parameters.

  15. Statistical uncertainty

  16. Systematic uncertainty

  17. Theoretical uncertainty • VP Wave function overlaps: ZNS=0.91±0.05; ZS=0.89±0.07; ZNS/ZS =1.02±0.10  ±10%  maximum variation P =±0.3º • ms/m= (1.24-1.45)  maximum variation P=±0.5º • Theo. unc. P=±0.6º

  18. Gluonic content

More Related