Compliance Monitoring Strategy CMS

bona avatar
15 diapositives · 455 Views · Aug 16, 2014

Compliance Monitoring Strategy CMS. Michael Pjetraj RCO. Compliance Monitoring Strategy CMS. Issued April 2001 http://www.epa.gov/Compliance/resources/policies/monitoring/cmspolicy.pdf EPA Emphasis on TV & 80% SM Facilities Minimum Evaluation Frequencies

Compliance Monitoring Strategy CMS - slide 1
01 / 15Compliance Monitoring Strategy CMS
1 / 17

Télécharger la présentation

Compliance Monitoring Strategy CMS
Une image / un lien ci-dessous est fourni (tel quel) pour télécharger la présentation

Politique de téléchargement : le contenu du site vous est fourni TEL QUEL pour votre information et votre usage personnel ; il ne peut être vendu, concédé sous licence ni partagé sur d’autres sites sans l’accord de son auteur.Le contenu vous est fourni TEL QUEL, pour votre information et votre usage personnel uniquement. Téléchargez la présentation en cliquant sur ce lien. Lors du téléchargement, si vous ne parvenez pas à télécharger une présentation, l’éditeur a peut-être supprimé le fichier de son serveur.Pendant le téléchargement, si vous ne parvenez pas à obtenir une présentation, le fichier a peut-être été supprimé par l’éditeur.

F I N

Plus de contenu associé

Transcription de la présentation
  1. Compliance Monitoring StrategyCMS Michael Pjetraj RCO

  2. Compliance Monitoring StrategyCMS • Issued April 2001 • http://www.epa.gov/Compliance/resources/policies/monitoring/cmspolicy.pdf • EPA Emphasis on TV & 80% SM Facilities • Minimum Evaluation Frequencies • “Three categories of compliance monitoring replace the current levels of inspection defined in the 1987 CAA Compliance/Enforcement Manual.”

  3. CMS • Full Compliance Evaluations • Partial Compliance Evaluations • Investigations

  4. FCE • Full Compliance Evaluation (FCE) • AFS code - FS (On site FCE by State) • Comprehensive evaluation of the compliance status of a facility. • Addresses all regulated pollutants at all regulated emission units; current compliance status of each emission unit; the facility’s continuing ability to maintain compliance at each unit.

  5. FCE includes: • A review of all required reports and underlying records including all reported monitored data (CEM records, malfunction reports, excess emission reports). • A review of TV annual compliance certifications, semi-annual monitoring and periodic monitoring reports, and any other permit required report.

  6. FCE includes: • An assessment of control device and process operating conditions as appropriate. • A VE observation as needed • A review of records an operating logs • An assessment of process parameters such as feed rates, raw material composition and process rates.

  7. FCE includes: • An assessment of control equipment performance parameters (water flow rate, pressure drop, temp, ESP power level, etc) • A stack test where there are no other means for determining compliance with emission limits. Factors for consideration: size of unit, duration since last test, margin of compliance in previous test, condition of control equipment, monitoring data.

  8. PCE: • Partial Compliance Evaluation (PCE) • AFS code - PS (On site PCE by State) • A documented compliance assessment focusing on a subset of regulated pollutants, regulatory requirements, or emission unit.

  9. Investigation • Limited portion of the facility, more resource intensive, in-depth assessment of a particular issue. It is usually based on information discovered during an FCE.

  10. Minimum CMS Frequencies • Full Compliance Evaluation (FCE/FS) Once every two years at all TV. Mega sites are allowed 3 years. • FCE/FS once every 5 years at Synthetic Minors • On site visit at a minimum of once every 5 years at TV

  11. Data coding • TV & SM inspections will be recorded as “FS: Full Compliance Evaluation by the State” Any “27” action types will be converted to FS once per month • TV & SM re-inspections will be recorded as “PS: Partial Compliance Evaluation by the State” Any “54” action types will be converted to PS once per month

  12. Data coding • The “Result Code” for any inspection action should be coded as either In compliance “MC” or In violation “MV” • Any non MV result for an FS action will be converted to MC

  13. Data coding • Tests: • That we observe: Action Type “23” • That we do not observe: Action Type 24 (converted to TR at the end of the month) • Result codes are PP for pass or FF for fail. Any MV action will be converted to FF. All other action result will be converted to PP.

  14. DAQ’s Requirements • TV facilities - inspected once per year • SM facilities - inspected once per year • Minor (small) facilities - inspected once every other year • Or a different plan as negotiated by the regional office & the central office.

  15. DAQ’s Requirements • NC DAQ continually evaluates the compliance status of a facility • Reports, Inventories, Tests, etc • We consider the on-site inspection to be the end of the full compliance evaluation period.