1 / 40

Energy Efficient Lighting

Energy Efficient Lighting. Overview. Fundamentals Light Quantity Light Quality Glare Energy efficiency Lighting and Productivity Inside-out Approach to Energy Efficient Lighting End-Use Maximize daylighting Deliver required quantity of lighting Distribution

Télécharger la présentation

Energy Efficient Lighting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Energy Efficient Lighting

  2. Overview • Fundamentals • Light Quantity • Light Quality • Glare • Energy efficiency • Lighting and Productivity • Inside-out Approach to Energy Efficient Lighting • End-Use • Maximize daylighting • Deliver required quantity of lighting • Distribution • Position lights effectively • Improve luminaire efficiency • Primary Energy Conversion • Install high-efficiency lighting • Quantifying Savings

  3. Light Quantity • Luminous flux • Quantity of visible light output, lumens, lm. • Illuminance • Luminous flux divided by area on which it is incident. • 1 footcandle = 1 lm/ft2 • Recommended illuminance increases as size and contrast of visual task decrease.

  4. Light Quality • Our eyes evolved to see in natural sunlight; thus, we distinguish colors best in sunlight. • Color Rendering Index (CRI) describes the effect of a light source on the color appearance of an object.

  5. HPS and HBF Lights (Same Facility with Same Camera) High Pressure Sodium High Bay Fluorescent Lights CRI = 22 CRI = 85

  6. Glare • Glare is very high contrast between lighting levels • Avoid glare with parabolic luminairs, light shelves, and reflective blinds.

  7. Energy Efficiency Lighting efficiency = (lm/W)light x (CU)fixture/room Efficient lighting: • High lm/W • High CU

  8. Characteristics of Superior Lighting • Correct Quantity • High Quality • Minimum Glare • Energy efficiency Superior Lighting

  9. Superior Lighting Increases Productivity • Reno post office lighting retrofit. • Energy savings = $22,400 /year • Productivity improvement = $400,000 /year • Pennsylvania Power and Light • Energy savings = $2,000 per year • Sick leave decreased from 72 to 54 hours/year • Lockheed Martin office with daylighting • Energy savings = 4-year payback • Absenteeism dropping by 15%: 1-year payback • California schools • Test scores 20% higher in schools with daylighting • Chain of 100+ retail stores • Sales higher in stores with sky lights Superior Lighting

  10. Inside-out Approach to Energy Efficient Lighting • End-Use • Deliver required quantity of lighting • Maximize daylighting • Distribution System • Position lights effectively • Improve luminaire efficiency • Primary Equipment • Install high-efficiency lighting

  11. Utilize Existing Daylighting Wright Brothers Factory, Dayton Ohio

  12. Utilize Existing Daylighting Bureau of Engraving and Printing, Washington D.C.

  13. Utilize Existing Daylighting- By Turning Off Lights Near Windows - • Known • 10 465-W MH fixtures near windows operating 6,000 hours/year • Action • Turn off 10 fixtures for 3,000 hours/yr • Savings • 10 fix x .465 kW/fix x 3,000 h/yr = 14,000 kWh/yr • 14,000 kWh/yr x $0.10 /kWh • = $1,400 /yr

  14. Restore Existing Daylighting- By Replacing Discolored Glass and Fiberglass with Corrugated Polycarbonate and Double Pane Lexan - CP costs same as FG, but 10x more light

  15. Install Skylights and Optimize Area • Optimum skylight/floor area ratio • Ranges from 1% to 6% • Increases with target lighting level • Decreases as lights are more efficient

  16. Reduce Excess Electric Lighting • Known • Measured = 50 fc • Required = 30 fc • Action • Disconnect (1- fcreq/fcmea) % of fixtures • Savings • Disconnect • = (1 – fcreq / fcmea) • = (1 – 30 / 50) • = 40% of fixtures

  17. Inside-out Approach to Energy Efficient Lighting • End-Use • Deliver required quantity of lighting • Maximize daylighting • Distribution System • Position lights effectively • Improve luminaire efficiency • Primary Equipment • Install high-efficiency lighting

  18. Disconnect Blocked Lights

  19. Position Task Lighting Above Work Areas

  20. Reposition Lights Below Scaffolding

  21. Use Reflectors that Push Light Onto Workplane Add reflectors to fluorescent strip lighting Replace acrylic with aluminum MH reflectors

  22. Paint Ceilings White

  23. Install Occupancy Sensors in Seldom Used Areas • Known • Occupancy sensors cost $15 - $80 each • 10 237-W T12 fixtures operating 6,000 hours/year • Action • Install occupancy sensors to turn off fixtures for 3,000 hours/yr • Savings • 10 fix x .237 kW/fix x 3,000 h/yr = 7,110 kWh/yr • 7,110 kWh/yr x $0.10 /kWh = $711 /yr

  24. Install Photocells On Outdoor Lights • Known • Photocell switches cost about $15 each • 10 465-W MH fixtures operating 6,000 hours/year • Action • Install photocells which turn off fixtures for 3,000 hours/yr • Savings • 10 fix x .465 kW/fix x 3,000 h/yr = 14,000 kWh/yr • 14,000 kWh/yr x $0.10 /kWh = $1,400 /yr

  25. Turn off Lights in Unused Areas

  26. Inside-out Approach to Energy Efficient Lighting • End-Use • Deliver required quantity of lighting • Maximize daylighting • Distribution System • Position lights effectively • Improve luminaire efficiency • Primary Equipment • Install high-efficiency lighting

  27. Replace Incandescent with Compact Fluorescent Lamps CF lamps • Use 75% less energy • Last 8-10 times longer • Result in less mercury emissions • Known • 100 100-W I lamps, life = 1,000 hours, cost = $1, operating 6,000 h/yr • Action • Replace with 23-W CF lamps, life = 10,000 hours, cost = $5 • Savings • 100 lamps x (.100 - .023) kW/lamp x 6,000 h/yr = 46,200 kWh/yr • 46,200 kWh/yr x $0.10 /kWh = $4,620 /yr • 100 lamps x 6,000 h/yr x ($1/1,000– $5/10,000) (h-lamp)-1 = $300 /yr • $4,620 /yr + $300 /yr = $4,920 /yr

  28. Replace T12 Lamps & Electro-magnetic Ballastswith T8 Lamps & Electronic Ballasts T8 XP lamps with LBF electronic ballasts: • Use 42% less energy and put same amount of light on workplane • Improve CRI and eliminate flicker • Known • 100 fixtures with four 34-W T12 lamps and electro-magnetic ballasts operating 6,000 h/yr • Action • Replace with four 28-W XP T8 lamps and LBF electronic ballasts • Savings • 100 fix x (.144 - .084) kW/fix x 6,000 h/yr = 36,000 kWh/yr • 36,000 kWh/yr x $0.10 /kWh = $3,600 /yr

  29. Replace Metal Halide with High Bay Fluorescent Lights High bay fluorescent (HBF) lights: • Reduce energy use by 50% or more • Improve CRI • Reduce maintenance costs • Stabilize light level • Improve light distribution • Can be turned on/off as needed, w/ occupancy or w/photocells

  30. Replace Metal Halide with High Bay Induction Lights • HBI uses 50% less energy than MH to produce same illuminance • HBI has instant restrike compared to 15-minute for MH • HBI CRI = 0.90 compared to CRI = 0.65 for MH • HBI lasts 100,000 hours compared to 20,000 hours for MH • HBI has reduced lumen degradation compared to MH (90% compared to 70% halfway through rated life) • HBI light output is insensitive to temperature

  31. Emerging Lighting Technologies: LEDs • Light emitting diodes (LEDs) currently used in: • Computer monitors and televisions • Exit signs, flashlights, etc. • Colored LEDs much more efficient than incandescent with colored filters. • California has replaced thousands of 150-W incandescent light bulbs that last about 1 year in traffic lights with red, yellow and green LEDs that consume about 15 W and last about 5 years. • White LED efficiency currently between incandescent and T8 fluorescent lights, but: • Efficiency is increasing quickly, theoretical efficiency = 100% • Distribution efficiency ~ 100% • LEDs last about 5 times as long as incandescent lights. • LEDs are next lighting revolution

  32. Quantifying Savings • Calculate number of proposed lights needed to deliver required footcandles. • Calculate annual energy cost savings from replacing the current lights. • Calculate annual relamping cost savings, including labor and material costs. • Calculate total annual cost savings including energy and relampingsavings. • Calculate the one-time implementation cost of replacing the current lights. • Calculate simple payback of the investment.

  33. Power Input Determined by Ballast – Not Lamp • Wattage on lamp is nominal value • Power input determined by ballast power • Example: 51-W Fluor F32T8 Low Output Electronic Ballast powering 2 x 32 W lamps. • Power input including ballast = 51 W (not 2 x 32 W = 64 W) • Example: 465-W MH ballast powering a 400-W MW lamp • Power input including ballast = 465 W (not 1 x 400 W = 400 W)

  34. Luminosity Determined by Lamp and Ballast • Mean output of lamp is nominal value • Light output = nominal lm/lamp x ballast factor • Ballast factor for fluourescents:high output ~1.2; normal output ~0.87, low output ~0.75 • Ballast factor for HIDs (MH, HPS)= 1.0 • Example: Fluor F32T8 Low Output Electronic Ballast powering 2 x 32 W lamps. • Light output = 2 x 2,710 lm x 0.75 = 4,065 lm • Example: MH 400-W lamp with nominal output 23,500 lm • Light output = 1 x 23,500 lm x 1.0 = 4,065 lm

  35. Coefficient of Utilization • CU is fraction light emitted by lamps delivered to workplane • CU is function of RCR, reflectance of walls, rw, and reflectance of ceiling, rc, and the fixture • RCR = 5 x h x (w + l) / (w x l) • Reflectance:

  36. Determine Required Number of Lights Illuminanceon a workplane, Ew (fc) is Ew (fc) = [LPF(lm/fix) x N(fix)] x CU / Aw(ft2) Thus, N = (Ew x Aw) / (CU x LPF)

  37. Lamp Replacement Costs The number of lamps that must be replaced each year, Nr, can be calculated as: Nr = Num lamps x annual operating hours / lamp lifetime Example: Calculate lamp replacement cost for 320 400-W MH fixtures if lights operate 8,000 hours per year. The cost of a 400-W MH lamp is about $23.The hourly wage for a skilled-trade electrician is $65 per hour, and it takes 30 minutes to replace a lamp. Nr = 320 lamps x 8,000 hours/year / 20,000 hours = 128 lamps/year Cost = 128 lamps/year x ($23 /lamp + (30/60 hours/lamp x $65 /hour)) Cost = $7,104 /year

  38. Natural Lighting Design Illuminanceon a workplane, Ew (fc) is Ew= (Eslx Asl) x tskylightx twellx CUroom / Aw Where, Esl can be calculated from: Esl= Ih (W/ft2) x 110 lm/W (luminous intensity of sunlight)

  39. Natural Lighting Design LightSim Lighting Simulation Software: • Uses TMY2, TMY3 or EPW weather data • Simulates illuminanceon a workplane, Ew (fc) • Calculates number of hours and fraction of time that natural lighting exceeds target illuminance.

  40. http://www.caranddriver.com/features/vws-transparent-factory Thank you!