130 likes | 460 Vues
Background. WINDOW 6 and THERM 6 are currently under development with new capabilities Calculate the SHGC and U-Factor of Woven Shades, Venetian Blinds, and Fritted GlassShading Systems Can Be LocatedIndoorBetween GlazingOutdoor. Project Objectives. Perform and coordinate the data collection
E N D
1. Validation of WINDOW 6 and THERM 6 for Use in Determining the Solar Heat Gain Coefficients and U-Factors of Complex Glazing Systems Research Project NFRC Project Number: 07-101-RP
NFRC 2009 Spring Membership Meeting
William C. duPont/Sunergy Consulting
W. Ross McCluney/Sun Pine Consulting
2. Background WINDOW 6 and THERM 6 are currently under development with new capabilities
Calculate the SHGC and U-Factor of
Woven Shades,
Venetian Blinds, and
Fritted Glass
Shading Systems Can Be Located
Indoor
Between Glazing
Outdoor
3. Project Objectives Perform and coordinate the data collection, research, and testing to evaluate the new features within WINDOW 6 and THERM 6
4. Project Tasks and Deliverables Task 1 – Literature Search (3 Months)
Compile and Evaluate Existing SHGC and U-Factor Test Results
Describe Existing Methods of Calculating SHGC and U-Factors
Task 2 – Perform Tests and Simulations (7 Months)
Identify and Procure Test Specimens
Perform SHGC and U-Factor Tests
Perform SHGC and U-Factor Simulations
Task 3 – Compare and Evaluate Results (2 Months)
Test and Simulation Results from Literature Search
SHGC and U-Factor Test Results
Task 4 – Status Reports & Papers (3 Months)
5. Task 1a: Existing Results Comparison Included SHGC & U-Factor Test & Simulation Results (20 Sets)
Manufacturer’s Test Results
Pella (of 20 sets of tests, 8 U-Factor & 8 SHGC Tests)
ODL Glazing Systems w/o Frames (2 U-Factor & 2 SHGC Tests)
ODL with Door Frames (2 U-Factor & 2 SHGC Tests)
Research Papers and Reports
ASHRAE 1311-RP (8 U-Factor & 8 SHGC Tests & Simulations)
Not-Included SHGC & U-Factor Test & Simulation Results
Manufacturer’s Test Results
Hunter Douglas (50-80 U-Factor and SHGC Tests)
Research Papers and Reports
ASHRAE RP 947 (6-10 SHGC Tests {Center-of-Glass})
NFRC Black Blind Tilted (6 SHGC Tests at 3 Laboratories)
NFRC Glass Block (3 SHGC Tests)
Lund University Research for PARASOL 2.0
6. Task 1b: Existing Methodologies Existing SHGC and U-Factor Calculation Methodologies
ISO 15099 (Window & Venetian Blind similar)
ISO 10077 & WIS (Venetian Blind similar)
ASHRAE 1311-RP ASHWAT Model (Venetian Blind similar)
Existing ASHRAE SHGC Load Calculation Method
IAC and Tables
ParaSol 2.0 (Lund University)
EN 14500 & EN 14501
7. Task 2a Overview Test Specimen List
26 SHGC Tests (2 U-Factors Simulated)
20 U-Factor Tests
Revised Test Specimen List
6 Simple Glazing System Tests
4 Reference Glazing
2 Fritted Glazing Samples (High & Low Density)
8 Inside Shading System Tests
4 Woven Blinds (Loose & Dense Weave, Tight & Loose Fit)
2 Venetian Blinds (Open, 45?, Closed, High & Low Absorptance)
10 Between-Glazing Shading System Tests
2 Woven Blinds
3 Venetian Blinds (Open, 45?, Closed, Thin & Thick Pane Spacing, High & Low Absorptance)
1 Retracted (Venetian Blind)
2 Outside Shading System Tests
2 Sunscreen (Loose and Dense Weave, High & Low Absorptance)
8. Task 2b Overview(Continued) Procure Test Specimens
Donation of Windows, Glazing and Shades
Marvin Windows and Doors
Pella Corporation
Viracon
Glen Raven Custom Fabrics
Phifer Wire
Hunter Douglas
Replaced Low-E Window (Original Clear Glass)
Need to Identify Glazing Layer with Properties of Shade
9. Task 2b Overview Perform SHGC Tests
Architectural Testing, Inc. in Fresno, CA (ATI) started SHGC Testing on October 6, 2008
PI Visit ATI during the week of October 6-10, 2008
15 of 26 SHGC Tests Completed
10. Task 2b Overview(Continued) Perform U-Factor Tests
Primary NFRC 102 Laboratory (All Tests)
Architectural Testing, Inc. in Fresno, CA (ATI)
Secondary NFRC 102 Laboratories (Two Specimens Each)
Architectural Testing, Inc. in St. Paul, MI
Architectural Testing, Inc. in York, PA
U-Factor Testing started October 3, 2008
PI Visit ATI during the week of October 6-10, 2008
10 of 20 U-Factor Tests Completed
11. Task 2b Overview(Continued)
12. Task 2c Overview Perform SHGC and U-Factor Simulations
Carli, Inc. has been Chosen as NFRC 100 and NFRC 200 Simulation Laboratory
Simulated as Tested
As Installed in Solar Calorimeter or Thermal Chamber
At Environmental Conditions Experienced During Testing
Simulation of New Test Results
Window Manufactures Have Donated WINDOW and THERM Files
Need to Procure Adequate Working Drawings and Bill of Materials of Some Windows
Need to Measure Optical Properties of Shade Materials
Simulation of Old Test Results
20 Comparisons Expected
2 Sets Center-of-Glass Only
13. Current Tasks Procure Working Drawings
Procure Optical Properties Test Results for Addition to WINDOW Shading Systems Library
Shade Manufacturers Have Agreed to Donate Test Results
Review Completed Test Results
Start Simulations...
14. Questions or Comments?