1 / 12

Code update

Code update. 2013-03-06 update [Option] Collision [Load] SQUARE. [Options] Collision = binary. 실행 시 메시지 출력 : Done. Collision turn on 주의사항 파티클 Load 항이 3 개 이상이면 프로그램이 정지되도록 해놓았음. [Load] SQUARE. [Load] SQUARE. x1min=-10 x1max=10 x2min=-10 x2max=10 sx1=-5 sx2=0 thickness=10.

cade-foley
Télécharger la présentation

Code update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Code update

  2. 2013-03-06 update[Option] Collision[Load] SQUARE

  3. [Options] Collision = binary 실행 시 메시지 출력: Done. Collision turn on 주의사항 파티클Load 항이 3개 이상이면 프로그램이 정지되도록 해놓았음.

  4. [Load] SQUARE

  5. [Load] SQUARE x1min=-10 x1max=10 x2min=-10 x2max=10 sx1=-5 sx2=0 thickness=10 frontslope1=1 backslope1=1 thickness frontslope1=1 backslope1=2 frontslope1=1 backslope1=-1

  6. [Load] SQUARE x1min=-10 x1max=10 x2min=-10 x2max=10 x3min=-10 x3max=10 sx1=0 sx2=0 sx3=0 thickness=10 frontslope1=1 frontslope2=1 frontslope3=1 backslope1=1 backslope2=1 backslope3=1 frontslope1=1 frontslope2=1 frontslope3=1 backslope1=2 backslope2=1 backslope3=1

  7. 2013-03-11 update[Load] MWPLASMA

  8. [Load] MWPLASMA [Load] SQUARE와 사용법은 같다. 2D, 3D 가능. frontslope1=1 frontslope2=0 frontslope3=1 backslope1=1 backslope2=0 backslope3=1 x1min=-5 x1max=5 x2min=-5 x2max=5 x3min=-5 x3max=5 sx1=10 sx2=0 sx3=0 thickness=10 x1min=-5e-5 x1max=5e-5 x2min=-5e-5 x2max=5e-5 x3min=-5e-5x3max=5e-5 sx1=10e-5 sx2=0 sx3=0 thickness=10e-5

  9. 2013-03-18 update[Load] MWPLASMAnTtype=SINE

  10. [Load] MWPLASMA 2D, 3D 가능. X1 방향으로 진행하는 MW만 가능 함수식: Transverse 방향만 설정 가능 Longitudinal 방향으로는 안됨 density n0 →transverse 0 sinMax sinMin

  11. [Load] MWPLASMA [Domain] x1min=0 x1max=3e-5 x2min=-3e-5 x2max=3e-5 shifrDomainDir = X1P [Load] Type = MWPLASMA n0=1e24 …. nFormula=LT nLtype=POLYGON nTtype=SINE sineMin=-3e-5 sineMax=3e-5 nLnodes=4 lpolyL0=0 lpolyL1=1e-5 lpolyL2=20e-5lpolyL3=25e-5 lpolyN0=0lpolyN1=1 lpolyN2=1lpolyN3=0 … Density, n0=1e24 y

More Related