1 / 21

Modeling biomass burnings by coupling a sub-grid scale plume model with Adaptive Grid CMAQ

Modeling biomass burnings by coupling a sub-grid scale plume model with Adaptive Grid CMAQ. Aika Yano Fernando Garcia-Menendez Yongtao Hu M. Talat Odman Gary Achtemeier (USDA Forest Service) D. Scott McRae (NC State) 9 th Annual CMAS Conference 11 October, 2010.

Télécharger la présentation

Modeling biomass burnings by coupling a sub-grid scale plume model with Adaptive Grid CMAQ

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Modeling biomass burnings by coupling a sub-grid scale plume model with Adaptive Grid CMAQ Aika Yano Fernando Garcia-Menendez Yongtao Hu M. Talat Odman Gary Achtemeier (USDA Forest Service) D. Scott McRae (NC State) 9th Annual CMAS Conference 11 October, 2010

  2. sub-grid scale plume model:Daysmoke

  3. Adaptive Grid - CMAQ

  4. AG-CMAQ vsDaysmoke AGD-CMAQ Objective: combine the two models to obtain the most detailed conc. in a grid model

  5. How to combine Daysmoke in AG-CMAQ? Emissions Chemical Coupling Handover d = downwind distance MM5 (WRF) Adaptor CMAQ Daysmoke Ambient concentrations Parcel/Puff/Plume concentrations Particles Parcels mixed in grid cells Meteorology Grid Support? Distributions Grid Grid Grid Concentrations Meteorology Meteorology Particles/CCN

  6. New CMAQ setup

  7. CMAQ_DAYSMOKE: Between VDIFF and COUPLE

  8. Handover

  9. Handover Remain in Daysmoke Emission added to grid concentration

  10. Atlanta Smoke Case Feb. 28 2007 Oconee NF (1542 acres) 5 yr old 10:00 am - 3:00 pm total 5hr Piedmont NWR (1460 acres) 1 yr old 11:00 am - 2:00 pm total 3hr

  11. Atlanta Smoke Case Feb. 28 2007

  12. Measurement Sites

  13. CMAQ vs AGD-CMAQ

  14. Model Comparison

  15. Mean Normalized Error

  16. Summary Inputting PB smoke emissions into grid concentrations can be varied in time and place using Handover method in AG-CMAQ coupled with Daysmoke (AGD-CMAQ) . On average, AGD-CMAQ has less error from the measured concentration than CMAQ and AG-CMAQ AGD-CMAQ seems to pick up the measured concentration peaks better

  17. Future work: changes in grid adaptation Emissions Chemical Coupling Handover d = downwind distance MM5 (WRF) Adaptor CMAQ Daysmoke Ambient concentrations Parcel/Puff/Plume concentrations Parcels Parcels mixed in grid cells Meteorology Grid Support? Distributions Grid Grid Grid Concentrations Meteorology Meteorology Particles/CCN

  18. Using Fourier Transform for grid adaptation

  19. Thank youQuestions/Comments

  20. Mean Normalized Error

  21. Fort McPherson

More Related