1 / 14

Stack Sampling Results Report

Stack Sampling Results Report. Cancelled report. It has the operating conditions of the source?. NO. yes. The sampling equipment has calibration certificate?. NO. yes. NO. Laboratory analysis reports comply the legal requirements?. yes. Analyze the report. Stack Sampling Results Report.

cemma
Télécharger la présentation

Stack Sampling Results Report

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. StackSamplingResultsReport

  2. Cancelledreport It has the operating conditions of the source? NO yes The sampling equipment has calibration certificate? NO yes NO Laboratory analysis reports comply the legal requirements? yes Analyze the report

  3. Stack Sampling Results Report • the results in concentration shall be expressed in the same oxygen content of the emission limit • To correct the oxygen is necessary to apply this expression: Where: y is the oxygen in the flue gas • x is the oxigen of the emission limit

  4. Stack Sampling Results Report Example: To correct a concentration obtained in a sampling (135 mg/Nm3 to 9% O2) for the content of 7% oxygen will be:

  5. Stack Sampling Results Report • the results in concentration shall be expressed in the same unit to the emission limit • Example: the average readings of continuous monitor of CO was 100 ppm, but emission limit is mg/Nm3

  6. ConcentrationConversion MM = molecular mass

  7. Stack Sampling Results Report • the results in concentration shall be expressed in the same unit to the emission limit • Example: the average readings of continuous monitor of CO was 100 ppm, but emission limit is mg/Nm3 124,944 mg/Nm3

  8. ConvertSO3 and H2SO4 to SOx Conc. SOX = Conc. SO2 + Conc. SO3 x 64/80 Conc. SOX = Conc. SO2 + Conc. H2SO4 x 64/98

  9. N = normal condition • CNTP 1 atm e 0°C 1 atm e 273 K 1 atm e 492 R

  10. Exercise: The source is attending the emission limits? • Source: Incinerador • EmissionLimitto PM: 70 mg/Nm3, base seca a 7% de O2 • Report: 1asample = 50,238 mg/Nm3, base seca a 12,2 % de O2 2asample = 43,951 mg/Nm3, base seca a 13,1 % de O2 3asample = 43,185 mg/Nm3, base seca a 12,7 % de O2

  11. Exercise: The source is attending the emission limits? • Source: Incinerador • EmissionLimittoSOx: 250 mg/Nm3, base seca a 7% de O2 • Report: Concentração de SO2 = 54,2 mg/Nm3, dry base, 12,2 % O2 Concentração de H2SO4= 11,4 mg/Nm3 , dry base, 12,2 % O2

  12. Exercise: The source is attending the emission limits? • Source: CementKiln • EmissionLimitto HF: 5 mg/Nm3, base seca a 7% de O2 Report: 1asample = 8,5 mg/Nm3, dry base, 7 % O2 2asample = ND 3asample = ND ND - notdetectable (quantitationlimit = 8 mg/Nm3)

  13. Exercise: The source is attending the emission limits? • Source: CementKiln • EmissionLimittoNOx: 650 mg/Nm3 • Report: the average readings of continuous monitor of NOx was 1000 ppm

  14. Thank you!!Gracias !!Obrigada !! mcpoli@sp.gov.br