1 / 24

1 st post launch SCIAMACHY calibration & Verification Meeting L1b

1 st post launch SCIAMACHY calibration & Verification Meeting L1b Astrium Friedrichshafen – Germany 24 July 2002 First Level 1b Spectral Calibration analysis. Level 1b Spectral Calibration analysis: content. The Spectral Calibration philosophy The Iecf Spectral Calibration Algorithm

cicily
Télécharger la présentation

1 st post launch SCIAMACHY calibration & Verification Meeting L1b

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 1st post launch SCIAMACHY calibration & Verification Meeting L1b Astrium Friedrichshafen – Germany 24 July 2002 First Level 1b Spectral Calibration analysis

  2. Level 1b Spectral Calibration analysis: content • The Spectral Calibration philosophy • The Iecf Spectral Calibration Algorithm • Related Verification Tasks: orbit behaviour • Analysis specifics • First results • Other Spectral Calibration Verification Tasks • Recommendations

  3. The Spectral Calibration Philosophy Objective: to assign a wavelength to each individualSCIA detector pixel during the flight. Method: the relation between pixel index and wavelength is described by a 4th order polynomial: To derive a set of calibration coefficients two calibration sources, the SLS and the sun, are analysed. Stability:due to ageing of the instrument, the wavelength parameters needs to be updated on a regular basis. Iecf, Instrument Engineering and Calibration Facility, guarantees long term stability of scientific measurements.

  4. The Iecf Spectral Calibration Algorithm Task: to determine coefficients of the 4th order polynomial for each channel as function of the orbital regions. Input: Level 1b Newly Calculated Spectral ADS Method: for each polynomial coefficient, given by the Spectral ADS as a function of orbital phase, a harmonic fit has to be performed in order to parameterise the orbital dependence. The coefficients values are then computed for a set of 12 fixed orbital phases:

  5. Related verification Task: orbit behaviour L1.01.02: Number of orbital regions for spectral calibration L1.09.03: Orbit region dependency Due to the instrument’s thermal environment along the orbit, the spectral calibration can be expected to show orbital dependency. Therefore SLS measurements shall be executed along the entire orbit to investigate whether the number of measurements and the number of orbital regions are sufficient and the orbit phase boundaries are chosen properly.

  6. Analysis specifics and overview Level 1b product: SCI_NL__0PNPDK20020621_182502_000062172007_00056_01613_0129.N1 Orbits: 1613 States: 10 SLS States (predefined State_ID 59), on 87 total States Channel 1: variation long the orbit is close or less to 1/100 of a pixel Channel 2: not analyseddue to erroneous key-data set used by the Level 0 to 1b processor Channels 3, 4, 5 and 6: variation long the orbit is close or less to 1/100 of a pixel Channel 7 and 8: not analysed for no in-flight dark current correction of the the raw lamp spectrum

  7. First Results: Orbit dependency for Channel 1 The algorithm performs correctly the harmonic fit of the coefficients. … but is this the best approach to the Spectral Calibration?

  8. First Results: Orbit dependency for Channel 3 The algorithm performs correctly the harmonic fit of the coefficients. … but is this the best approach to the Spectral Calibration?

  9. First Results: Orbit dependency for Channel 4 The algorithm performs correctly the harmonic fit of the coefficients. … but is this the best approach to the Spectral Calibration?

  10. First Results: Orbit dependency for Channel 5 The algorithm performs correctly the harmonic fit of the coefficients. … but is this the best approach to the Spectral Calibration?

  11. First Results: Orbit dependency for Channel 6 The algorithm performs correctly the harmonic fit of the coefficients. … but is this the best approach to the Spectral Calibration?

  12. First Analysis: the harmonic fit approach for Channel 1Orbit 1613 Maximum variation long the orbit: 1.1509E-03 nm or 0.01 of a pixel

  13. First Analysis: the harmonic fit approach for Channel 3Orbit 1613 Maximum variation long the orbit: 2.1606E-02 nm or 0.090 of a pixel

  14. First Analysis: the harmonic fit approach for Channel 4Orbit 1613 Maximum variation long the orbit: 1.5229E-03nm or 0.007 of a pixel

  15. First Analysis: the harmonic fit approach for Channel 5Orbit 1613 Maximum variation long the orbit: 2.0408E-02nm or 0.07 of a pixel

  16. First Analysis: the harmonic fit approach for Channel 6Orbit 1613 Maximum variation long the orbit: 3.2390E-02nm or 0.041 of a pixel

  17. First analysis: variation on the input for Channel 1Coefficient average long the orbit as reference Maximum variation long the orbit from average: 1.5786E-03nm or 0.013 of a pixel Maximum variation long the orbit from fit: 1.1509E-03 nm or 0.01 of a pixel

  18. First analysis: variation on the input for Channel 3Coefficient average long the orbit as reference Maximum variation long the orbit from average: 2.2911E-03nm or 0.010 of a pixel Maximum variation long the orbit from fit: 2.1606E-02 nm or 0.090 of a pixel

  19. First analysis: variation on the input for Channel 4Coefficient average long the orbit as reference Maximum variation long the orbit from average: 1.8100E-03nm or 0.008 of a pixel Maximum variation long the orbit from fit: 1.5229E-03nm or 0.007 of a pixel

  20. First analysis: variation on the input for Channel 5Coefficient average long the orbit as reference Maximum variation long the orbit from average: 3.2879E-03nm or 0.012 of a pixel Maximum variation long the orbit: 2.0408E-02nm or 0.07 of a pixel

  21. First analysis: variation on the input for Channel 6Coefficient average long the orbit as reference Maximum variation long the orbit from average: 4.2989E-03nm or 0.006 of a pixel Maximum variation long the orbit: 3.2390E-02nm or 0.041 of a pixel

  22. First Analysis: Summary

  23. All Spectral Cal Related Verification Tasks • L1.01.02 Number of orbital regions for spectral calibration • L1.02.03 Wavelength calibration - selected line list not changes • L1.02.04 Slit function parameters unchanged • L1.09.01 Verification of precise basis for spectral calibration • L1.09.02 Verification of selected lines for calibration • L1.09.03 Verify orbit region dependency • L1.09.04 Verify whether SLS or Fraunhofer calibration shall be the baseline • L1.14.01: Wavelength calibration differences monitoring

  24. Level 1b Spectral Calibration analysis: Recommendations • The approach averaging the coefficients from the Level 1b seems to give better results • Fit based on a lower order polynomial shall be investigated • …

More Related