1 / 26

ISaGRAF PACs

ISaGRAF PACs. By Chun Tsai chun@icpdas.com ICP DAS CO., LTD. service@icpdas.com . PAC ( P rogrammable A utomation C ontroller). XPAC XP / WinCE 6.0 based. LinPAC Linux based. ISaGRAF PAC. WinPAC WinCE 5.0 based. iPAC MiniOS7 based. µPAC MiniOS7 based. ViewPAC

clancy
Télécharger la présentation

ISaGRAF PACs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ISaGRAF PACs By Chun Tsai chun@icpdas.com ICP DAS CO., LTD. service@icpdas.com

  2. PAC(Programmable Automation Controller) XPAC XP / WinCE 6.0 based LinPAC Linux based ISaGRAF PAC WinPAC WinCE 5.0 based iPAC MiniOS7 based µPAC MiniOS7 based ViewPAC WinCE/MiniOS7 based ICP DAS PAC

  3. WinCE Based PAC CPU 520 MHz Flash 128 MB SDRAM 128 MB VGA 800 x 600 (WP-8x47) 1024 x 768 (WP-8x37) USB x 2 Ethernet x 2 RS-232/485 I/O Slot WinPAC WP-8xx7 ViewPAC VP-2xW7 XPAC XP-8xx7-CE6 CPU 520 MHz Flash 96 MB RAM 128 MB TFT LCD 640 x 480 USB x 1 Ethernet x 1 RS-232/485 I/O Slot CPU 500 MHz Flash 4 GB SDRAM 512 MB VGA 1024 x 768 USB x 2 Ethernet x 2 RS-232/485 port I/O Slot VP-25W7 (with Touch) VP-23W7 (no touch) Speed : XP-8xx7-CE6 > WP-8xx7 >= VP-2xW7 ICP DAS www.icpdas.com service@icpdas.com

  4. MiniOS7 Based PAC CPU 80186, 80MHz Flash 512 KB SRAM 768 KB Ethernet x 2 RS-232/485 I/O Slot iPAC iP-8x47 µPAC µPAC-5x07 µPAC-7186EG ViewPAC VP-2117 CPU 80186. 80MHz Flash 512 KB RAM 768 KB STN LCD128 x 64 Keypad 24 keys Ethernet x 1 RS-232/485 I/O Slot x 3 CPU 80186, 80MHz Flash 512 KB SRAM 768/640 KB Ethernet x 1 RS-232/485 I/O Expansion Bus *Power over Ethernet *GPS / GPRS (* optional module) ICP DAS www.icpdas.com service@icpdas.com

  5. ISaGRAF Features • All-in-one System Design • Easy SoftLogic Syntax • IEC 61131-3 Standard • Simple HMI & MMI SimulatewithoutPAC Debug / Control / MonitorOn-Line SixOpenPLC Languages (LD, ST, ..) ISaGRAF Workbench Development ISaGRAF PAC Runtime

  6. ISaGRAF+ Soft-GRAF HMI • All-in-onedesignControllogic&HMI ISaGRAF All-in-one • Various& colorful HMI objectsPage,Numeric,Moving TraceText(dynamic/static),Picture(animated/static) Soft-GRAF HMI • Multi-language English, TraditionalChinese, Simplify Chinese,... • HMI behave smoothly I/OControl/monitor XP-8xx7-CE6,WP-8xx7,VP-2xW7. (Not For miniOS PAC)

  7. Development Software: ISaGRAF ISaGRAF-256-E ISaGRAF-256-C ISaGRAF-32-E ISaGRAF-32-C • ISaGRAF Ver. 3 Programming ISaGRAF PACs • Advanced Application Book (-E: English; -C: Chinese) • 256 I/O Tags • 1 USB Dongle • 32 I/O Tags • Remote I/O are not counted in tags . Using ISaGRAF-32 can control more than 32 I/O tags. (Eng.)(Chi.) ICP DAS www.icpdas.com service@icpdas.com

  8. ISaGRAF + InduSoft = WP-8xx6 / XP-8xx7-CE6 • Hardware Feature :WP-8x46=WP-8x47 XP-8x46-CE6=XP-8x47-CE6 Software Feature :+ ICP DAS www.icpdas.com service@icpdas.com

  9. Modbus TCP protocols Modbus RTU protocols

  10. Local/Remote I/O Application Modbus TCP/IP Slave Devices Remote I/O I-7000 / M-7000 I/O ET-7000 I/O ISaGRAF PAC • RU-87P4/8 + I-87K I/O • Hot-Swap • Auto-Configuration at run time • Plug & Play at run time • High Profile I-87K I/O only RS-485 Ethernet Switch NS-208/205 Ethernet Modbus TCP/IP Master XPAC WinPAC µPAC ViewPAC iPAC • Local I/O : I-87K / I-8K I/O • More than 100 models • WP, iP, VP PAC support High Profile I/O only : I-8K & I-87K (Hot-Swap) • Local I/O : X-Board (Expansion card) • Expand more I/O channels, COM ports, SRAM memory ICP DAS www.icpdas.com service@icpdas.com

  11. Modbus RTU / ASCII Master Devices are slaves PAC is Master Each RS-485 port can have only one Modbus Master and can connect up to 32 Modbus Slaves. XP-8xx7-CE6 can enable max. 32 ports as Modbus master ports. WP-8xx7 and VP-25W7 can enable max. 10 ports as Modbus master ports. ICP DAS www.icpdas.com service@icpdas.com

  12. Modbus TCP Master Devices are slaves PAC is master MiniOS7 PAC no supports Modbus TCP Master. However all ISaGRAF PAC with Ethernet port support Modbus TCP slave to be connected by PC / HMI / SCADA. ICP DAS www.icpdas.com service@icpdas.com

  13. Modbus TCP Slave / RTU Slave Max. Modbus RTU slave port: 9 ports (XP-8xx7-CE6 ) 5 ports (WP-8xx7 , VP-25W7) 2 ports (iP-8xx7, uP-7186EG) Max. Modbus TCP slave connections: 64 (XP-8xx7-CE6 ) 32 (WP-8xx7 , VP-25W7) 6 (iP-8xx7, uP-7186EG) ICP DAS www.icpdas.com service@icpdas.com

  14. Redundant System – Hot-Swap For ISaGRAF PACs: XP-8xx7-CE6 WP-8xx7, VP-2xW7, ICP DAS www.icpdas.com service@icpdas.com

  15. Redundant System – EthernetI/O Backup PAC Main PAC For ISaGRAF PACs: XP-8xx7-CE6 WP-8xx7, VP-2xW7 ICP DAS www.icpdas.com service@icpdas.com

  16. GPS Application: Using GPS-721 or I-8721W For ISaGRAF PACs: XP-8xx7-CE6, WP-8xx7, VP-2xW7, iP-8x47, µPAC-7186EG GPS-721 iP-8x47 WP-8xx7 XP-8xx7-CE6 µPAC-7186(P)EG VP-2xW7 I-8721W ICP DAS www.icpdas.com service@icpdas.com

  17. MotionControlSolution Only For ISaGRAF PACs: XP-8347-CE6 / XP-8747-CE6 XP-8xx7-CE6 I/ODevices I-8K,I-87K Soft-GRAF HMI MotionCard I-8092F I-8094F I-8094F TerminalBoard MotionControl ServoMotors MotionDevices

  18. Database Solution 18

  19. ZigBee Wireless Solution For ISaGRAF PACs: WP-8xx7, VP-25W7, iP-8x47, µPAC-7186(P)EG ZB-2551P (Slave) ZB-2550P (Host) ISaGRAF PAC XPAC, WinPAC ViewPAC iPAC, µPAC ZB-2000P Series I/O NET-ID: 8 NET-ID: 9 ZB-2550P (Host) ZB-2551P (Slave) ZB-2551P (Slave) ICP DAS www.icpdas.com service@icpdas.com

  20. CAN Network: CAN / CANopen ISaGRAF PACs support I-7530 : XP-8xx7-CE6 WP-8xx7, VP-2xx7, iP-8x47, µPAC-7186EG ISaGRAF PAC support I-8123W : XP-8xx7-CE6 WP-8xx7, VP-2xx7 ICP DAS www.icpdas.com service@icpdas.com

  21. Fast FRnet Remote I/O Modules Max. distance 400 M Max. distance 400 M For ISaGRAF PACs: XP-8xx7-CE6 WP-8xx7/8xx6, VP-2xx7, iP-8x47, µPAC-7186EG ICP DAS www.icpdas.com service@icpdas.com

  22. Stress Monitoring of Constructions Bridge Dam Building VW Sensor Application: XP-8xx7-CE6, WP-8xx7/8xx6, VP-2xx7, iP-8x47 Carlson Strain Gauge Inputs Application: XP-8xx7-CE6, WP-8xx7/8xx6, VP-2xW7 ICP DAS www.icpdas.com service@icpdas.com

  23. Runaway Application 10 ms 10 ms - ALTAMIRA RUNAWAY SYSTEM LAYOUT - 360 ms Sensor 2a Sensor 1a Fbus 800 m, 19200 bps SWITCH CONTROLLER DIO µPAC -7186EG +X107 SPEED TRAP µPAC -7186EG +X107 RS-485 RS-485 µPAC -7186EG +X107 µPAC -7186EG +X107 Inductive sensors digital output (PNP) I/O field interface Switch Machine Sensor 1a Sensor 2a 10 m 10 m Design max train speed = 100 Km/h ICP DAS www.icpdas.com service@icpdas.com

  24. Car Testing iPAC + I-8000 I/O boards ICP DAS www.icpdas.com service@icpdas.com

  25. InduSoft For Cooler ControlRoss & Christopher, California ISaGRAF + InduSoft AP Some W-8736 + I-87K & I-7000 Remote IO Remote Monitoring via Internet (InduSoft provide Web Thin Client) ICP DAS www.icpdas.com service@icpdas.com

  26. Thank you! Service : service@icpdas.com Data Sheet :www.icpdas.com > ISaGRAF SoftLogic PAC > Data Sheet FAQ : www.icpdas.com > FAQ > Software > ISaGRAF

More Related