An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Provision of Partial Baseband Private Circuits - Change-over Considerations Mike Ainger Transmission Design & Planning Manager Racal Telecom The contents of this document are for discussion only, and do not represent or imply a commitment by any company to implement of supply any of the technology, processes or products described

  2. Background • The order process is likely to result in one of two different implementation scenarios: • New PBPC over previously spare copper pair • New PBLC over copper pair in use for Telephony • In the first scenario there is no requirement for a live service change-over • In the second a live service change-over must be executed • This will in most cases be combined with a number port

  3. Streamlining the Change-over • It is in all parties interest that this change-over should be as efficient and interruption-less as possible: • Customer wants minimum service disruption • BT and OLO want to minimise skilled resources, in particular wasted resources co-ordinating timed activities • Public safety consideration - minimum interruption to emergency access

  4. Possible Methods (1) • BT installs NT 2000 and test access x-connect as a preparatory step • Also gives opportunity to label any BT owned CPE to avoid accidental recovery by OLO / customer Property of BT 1 2 CPE 0171 904 5710 2w Circuit MDF NT 2000 Test Access Cross-Connect BT Switch

  5. Possible Methods (2) • Number Transfer to the incoming operator to be implemented in advance of the PBPC implementation • Timed visit to port number could be done when OLO installs (but does not bring into service) DSL equipment Property of BT 1 2 2w Circuit MDF Test Access Cross-Connect Property of OLO BT Switch DSL

  6. Possible Methods (3) • If BT could now use the Test Access Cross-connect to remotely transfer the line to the incoming OLO: • Timed visit would be eliminated • If trouble experienced on change-over then reversion is simple - avoids risk of long periods without emergency access • First the OLO Equipment would be connected to the Test Access Cross-Connect Property of BT 1 DSL AM 2 2w Circuit MDF OLO Equipment Test Access Cross-Connect Property of OLO DSL BT Switch

  7. Possible Methods (4) • BT would then remotely switch-over, on request from the OLO, when the OLO technician is at the customer premises • The OLO then commission the new service, ensuring continuity of emergency access (by mobile if necessary) • Reversion can be invoked as a last resort Property of BT 1 DSL AM Property of OLO 2 2w Circuit MDF OLO Equipment Test Access Cross-Connect DSL BT Switch

  8. Possible Methods (5) • BT then complete the implementation - at their leisure • Recover BT Owned CPE • Connect remote line test equipment to test access cross -connect in place of BT switching equipment 1 DSL AM Property of OLO 2 2w Circuit MDF OLO Equipment Test Access Cross-Connect DSL Line Test Equipment

  9. Conclusions • The live service change-over arrangements, combined with number portability, create a complex change-over arrangement • Specific measures need to be adopted to reduce the dependence on (multiple) timed visits for change-over • These measures could either be available on day one, or introduced in a roll-out plan as the systems and processes become available (which should align with the volumes rising).