1 / 24

Grocery Store Measures

Grocery Store Measures. Door Gasket Laboratory Testing. Agenda. BPA Recommendations Gasket Damage, Door Open Times & Gasket Cost Data Emerson Lab Test Results Next Steps. I. BPA Recommendations. Door Gaskets – Deemed Measure Automatic Door Closer – Deemed Measure.

clint
Télécharger la présentation

Grocery Store Measures

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Grocery Store Measures Door Gasket Laboratory Testing

  2. Agenda • BPA Recommendations • Gasket Damage, Door Open Times & Gasket Cost Data • Emerson Lab Test Results • Next Steps

  3. I. BPA Recommendations • Door Gaskets – Deemed Measure • Automatic Door Closer – Deemed Measure

  4. Comparison of Savings (kWh/year/door) • Notes: • Assumes gasket length of 15' for Reach-In and 20' for Walk-In • Emerson Lab Testing: BPA sponsored Emerson study • SCE: So. Calif. Edison Work Papers WPSCNRRN0013 (10/2007) and WPSCNRRN0001, Revision 1 (10/2007)

  5. II. Gasket Damage Basis for Lab Testing (Ref. Phase 1 Report, 2/2007). • Reach-in Low Temp: Very high level of damage near the handle. Typical tear is 6-12 inches • Reach-in Medium Temp: Typically at bottom of door. Typical tear is 6-12 inches. Ten to twenty percent of damaged gaskets prevent door closure. • Walk-in Low & Medium Temp: Typical tears are: • Two to three feet in length • Completely missing several feet of gasket • Similar to Swiss cheese in appearance • Hard, brittle and blocking door closure • The standard used for repair in the PNW is a minimum 6” double tear. A man’s fist should generally fit comfortably through the tear.

  6. Door Open Times Methodology: Total of (38) cases monitored at (10) sites: 14 walk-ins & 24 reach-ins Field Installed, Hobo U-9-001 State Loggers, in place 1 to 4 weeks

  7. Cost Information

  8. III. Lab Testing

  9. Laboratory Testing – Interim Results • Completed Gasket and Auto Closer testing and report: • Low temperature reach-in • Low temperature walk-in • Medium temperature walk-in • Completed testing on strip curtains – report under review.

  10. Low Temperature Reach-In Results

  11. Low Temperature Walk-In Results

  12. Medium Temperature Walk-In Results

  13. Next Steps • Finalize report on strip curtains • Conduct UA-testing on walk-in • Evaluate results with wider audience including peer review. Prepare technical paper. • Incorporate revised results into ESG, as appropriate

  14. Supporting Slides Door Gasket Laboratory Testing

  15. Steady State Operation Anomalies(Full Gasket / Damaged Gasket) • Condenser Air Inlet • Full: 74.5 F. • Damaged: 72.5 F. • Saturated Suction Temperature • -36 F. • -32 F. • Compressor Operating EER • Full: 3.84 • Damaged: 4.24

  16. Anomaly Impact on Test Summary Full Gasket test negatively impacted by 1.7 kWh per day

  17. Normalized Energy Results Full Damaged 24 Hour Energy (kWh) 52.6 / 50.9* 54.3 / 54.3 Daily Increase (kWh) Baseline 1.68 / 3.4* % Daily Increase Baseline 3.2% / 6.7%* *Italics: original number Bold: Normalized number

  18. Door Open Time Study • Total of (38) cases monitored at (10) sites • Mix of Walk-Ins and Reach-Ins • Field Installed • Hobo U-9-001 State Loggers • At least one week; up to four weeks

  19. Duration of Door Openings (Minutes)

  20. Door Open Times – by Case Type

  21. Door Open Times

  22. Product Type

  23. Estimated Annual Energy Savings - Door Closers

  24. History – Average Gasket Damage