An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ultrasonic Fetal Monitor UFM-1000A www.medzer.com | info@medzer.net

  2. Specifications : FHR Probe: nine-unit, wide range, pulse wave, high sensitivity Signal Strength: < 1 mw/cm2 Frequency: 1.0 MHz Signal processing: DSP processor Max Sound Power: 1.5 W TOCO Pressure Range: 20 ~ 100 units

  3. Maternal ECG Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed Gains options: × 1, × 2, × 4, and × 0.5 four trenches Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls HR: ± 5 bpm Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-1.0mV ~ +1.0mV) Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical)

  4. NIBP measurement Technology: Oscillometric Mode: Manual / Automatic Measurement units: mmHg / kPa Measurement time: less than 45 s Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120 mmHg newborn children 70 mmHg) Inflatable cuffs follow: original SBP: + 30 mmHg Blood pressure measuring range: Systolic blood pressure: 60-250 mmHg Diastolic blood pressure: 40-220 mmHg Pressure on the average: 45- 235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm)

  5. 2 SpO measurement Range: 0 ~ 100% Accuracy: 1% Resolution: 1% Pulse frequency: 20 ~ 250 times / min Response time: 1s Alarm: Sound and Light Preset range: report (Alarm over preset numerical) Ceiling: 1% ~ 100% adjustable Threshold: 0% ~ 99% adjustable

  6. TEMP measurement Technology: thermostat temperature probe temperature Measuring range: 20 ° C ~ 45 ° C Temperature resolution: 0.1% Accuracy: ± 1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable

  7. RESP measurement Breathing frequency range: 0- 60 bpm Accuracy: ± 1 breath/m Response time: 1s Gains options: × 1, × 2, × 4, and × 0.5 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable

  8. Trend Types: Graphical /tabular Memory storage: 384 hours (not restart preservation) Data interval: 30 seconds Graphic form: one graph per channel Tabular form: graphics are the parameters with 8 per trip (and time parameters). One page 20 firms external

  9. Power AC power supply: AC 180-220V, 50Hz-60Hz. 1A maximum current Temperature: 0 ~ 40 ° C Storage temperature: -20 °C ~ 50 °C Working humidity: 5% ~ 95% relative humidity, non- condensing Humidity storage: 5% ~ 95% relative humidity, non- condensing Altitude: 0 ~ 1000 feet (working condition) Power: < 40W Features : 2 Parameters: FHR/ TOCO /ECG /NIBP / SpO /TEMP/RESP ST segment analysis Double security protection Large storage memory

  10. Medzer Inc Brandy Wine, 1000 N West St, Wilmington, DE 19801, United States Email: info@medzer.com | Website: www.medzer.com