0 likes | 14 Vues
Check out our cardiotocography machines. To ensure the best care for expecting mothers and their unborn children, purchase cutting-edge CTG devices.
E N D
Ultrasonic Fetal Monitor UFM-1000A www.medzer.com | info@medzer.net
Specifications : FHR Probe: nine-unit, wide range, pulse wave, high sensitivity Signal Strength: < 1 mw/cm2 Frequency: 1.0 MHz Signal processing: DSP processor Max Sound Power: 1.5 W TOCO Pressure Range: 20 ~ 100 units
Maternal ECG Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed Gains options: × 1, × 2, × 4, and × 0.5 four trenches Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls HR: ± 5 bpm Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-1.0mV ~ +1.0mV) Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical)
NIBP measurement Technology: Oscillometric Mode: Manual / Automatic Measurement units: mmHg / kPa Measurement time: less than 45 s Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120 mmHg newborn children 70 mmHg) Inflatable cuffs follow: original SBP: + 30 mmHg Blood pressure measuring range: Systolic blood pressure: 60-250 mmHg Diastolic blood pressure: 40-220 mmHg Pressure on the average: 45- 235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm)
2 SpO measurement Range: 0 ~ 100% Accuracy: 1% Resolution: 1% Pulse frequency: 20 ~ 250 times / min Response time: 1s Alarm: Sound and Light Preset range: report (Alarm over preset numerical) Ceiling: 1% ~ 100% adjustable Threshold: 0% ~ 99% adjustable
TEMP measurement Technology: thermostat temperature probe temperature Measuring range: 20 ° C ~ 45 ° C Temperature resolution: 0.1% Accuracy: ± 1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable
RESP measurement Breathing frequency range: 0- 60 bpm Accuracy: ± 1 breath/m Response time: 1s Gains options: × 1, × 2, × 4, and × 0.5 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable
Trend Types: Graphical /tabular Memory storage: 384 hours (not restart preservation) Data interval: 30 seconds Graphic form: one graph per channel Tabular form: graphics are the parameters with 8 per trip (and time parameters). One page 20 firms external
Power AC power supply: AC 180-220V, 50Hz-60Hz. 1A maximum current Temperature: 0 ~ 40 ° C Storage temperature: -20 °C ~ 50 °C Working humidity: 5% ~ 95% relative humidity, non- condensing Humidity storage: 5% ~ 95% relative humidity, non- condensing Altitude: 0 ~ 1000 feet (working condition) Power: < 40W Features : 2 Parameters: FHR/ TOCO /ECG /NIBP / SpO /TEMP/RESP ST segment analysis Double security protection Large storage memory
Medzer Inc Brandy Wine, 1000 N West St, Wilmington, DE 19801, United States Email: info@medzer.com | Website: www.medzer.com