1 / 12

Mitigation Dust Loading REMP Air Samplers

Mitigation Dust Loading REMP Air Samplers. Dust Loading Definition / Symptoms. Accumulation of loose particulate matter on air sampling particulate filter media Reduction in air sampler flow rate due to accumulation of material on the air sampler surface

didrika
Télécharger la présentation

Mitigation Dust Loading REMP Air Samplers

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Mitigation Dust Loading REMP Air Samplers

  2. Dust Loading Definition / Symptoms • Accumulation of loose particulate matter on air sampling particulate filter media • Reduction in air sampler flow rate due to accumulation of material on the air sampler surface • Increase in back pressure across air sample filter media

  3. Why it’s a Problem • Dust loaded REMP air samples may not be representative • Chronically dust loaded air sampling equipment may be more prone to mechanical failure

  4. REMP Air Sampler Dust Loading at SONGS • REMP air sampling apparatus consisted of sample line feed from the exterior of the “doghouse” style enclosure to and in-line type sample cartridge • Observed loose particulate matter on most REMP air sampler • Occasional episodes of reduced flow and increased media back pressure ~ 5% of samples dust loaded

  5. Proposed Remedy • Change sampling method from in-line type to open face sample method • Sampling method recommended by subject matter experts • DOE reference

  6. Comparison of Open Face Sampling to In-Line Sampling Method at SONGS • Two (2) auxiliary open face samplers were installed at the same location as two REMP stations • Duplicate data collected for 15 months

  7. Data and Observations • Open face sample cartridge samplers had no observed loose particulate matter • Most in-line type samples had loose particulate matter on the filter media • 15 month in-line type sample gross beta data was about 7% higher than the open face gross beta data • About 5% of the in-line samples were dust loaded (increased back pressure and /or reduced flow) • Open face samplers had no observed occurrences of dust loading during the study period