Project PATOV

Project PATOV. P rocess A nalytical T echnology Unit for O nline V erification of the CIP Process in the Pharmaceutical Industry Stefan Pohn Markus Brandstetter Tanja Siegmann- Hegerfeld Michael Harasek mharasek@mail.zserv.tuwien.ac.at www.patov.eu. Project PATOV.

dominic
Télécharger la présentation

Project PATOV

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Project PATOV Process Analytical Technology Unit for Online Verification of the CIP Process in the Pharmaceutical Industry Stefan Pohn Markus Brandstetter Tanja Siegmann-Hegerfeld Michael Harasek mharasek@mail.zserv.tuwien.ac.at www.patov.eu

  2. Project PATOV • Actual technologies for measuring the contamination in Cleaning in Place (CIP) waste water are slow (~10min) • The aimisto find a newtechnologyfor online verification • Implementing an IR technology (~1 measurementevery 1-30s) • Realisedwithintheproject PATOV, financedbythe 7th Framework Program ofthe EU

  3. Project PATOV • Experimental CIP plant installed at Vienna University of Technology • Plant is able to reproduce a CIP procedure • Resultsachievedwiththe IR equipmentarevalidatedwith offline TOC (total organiccarbon) measurements • PATOV isplacedclosetothe CIP plant tomeasurethecontamination in the CIP processwater

  4. Project PATOV • Schematic of experimental CIP plantwith PATOV unit

  5. Project PATOV PATOV unit CIP waterstorage tank Vesselthat has to becleaned Pumps forcyclingthewater Connection PATOV-CIP system

  6. Project PATOV Actual Status of the Project • At the moment it is possible to make a measurement every second • Down to a concentration of 20ppm • Retention time from the CIP plant to the PATOV unit was brought down to 15s • Only one contaminant can be measured at the moment, the calibration for other contaminants, like proteins is planned

  7. Project PATOV Project Partners Visitus @ www.patov.eu