1 / 16

DEN/CAD/DTN

DEN/CAD/DTN. Necessary work for PACTITER Development and validation F. Dacquait*, V. Blet**, F. Nguyen* *DTN/SMTM/LMTR **DTN/STRI/LTCD. Status of the PACTITER Code Development. Status of the PACTITER Code Development (continued). Main references.

dominy
Télécharger la présentation

DEN/CAD/DTN

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DEN/CAD/DTN Necessary work for PACTITERDevelopment and validationF. Dacquait*, V. Blet**, F. Nguyen**DTN/SMTM/LMTR **DTN/STRI/LTCD

  2. Status of the PACTITER Code Development

  3. Status of the PACTITER Code Development (continued)

  4. Main references • F. Dacquait (2003), “Status of CORELE”, Meeting on the CORELE programme CEA-EFDA-ENEA, Cadarache, May 13, 2003 • F. Dacquait et al. (2003), “Qualification du système de rétention d’ions de la boucle CORELE”, CEA NT DEC/S3C/03-162, December 2003 • F. Dacquait (2004), “PACTITER V2 vs V2.1”, CEA Letter DTN/SMTM/LMTR 24, March 2004 • F. Dacquait et al. (2004), “Status of PACTITER”, CEA DTN/SMTM/04-117, December 2004 • F. Dacquait et al. (2005), “Preliminary requirements for the development and validation programme of the PACTITER code”, CEA DTN/SMTM/05-09, February 2005 • T. Duverneix et al. (1999), “Definition of the CORELE test matrix for ITER purpose”, CEA NT DEC/SH2C/LTC/98-176 V1, September 1999 • T. Duverneix, V. Biscay (2001), “Report on ITER 01 and ITER 02 tests in the CORELE 2 loop”, CEA NT DEC/S3C/01-099, December 2001 • M. Girard (2004), “Validation of EU Safety Computer codes : validation of PACTITER on the CIRENE experiment - Feasibility study”, CEA NT DTN/STRI/LTCD/04-021, December 2004 • J.C. Robin (1995), “Adaptation of PACTOLE for fusion application”, CEA NT DEC/SECA/LTC/95-255, December 1995 • P. Schindler (2004), “ITER 2004 tests report – Stainless steel release rate evaluation in ITER operating conditions”, CEA NT DTN/STRI/LTCD/04-020, December 2004 • D. Tarabelli (1998), “PACTITER (PACTOLE version for ITER) - Final report”, CEA NT DEC/SECA/LTC/98-150, June 1998 • D. You et al. (1997), “Thermodynamic stability and solubility of Vopper and Copper oxides”, CEA RT-SCECF 420, May 199714

  5. PACTITER V3.0 • PACTOLE V3.0 adaptation to ITER conditions in 2004 • Main changes compared with PACTITER V2.1 • Corrosion and release model (input data) • No solubility correction • Instationnary mass balance equation (simulation of pulsed operation) • Non-limited number of elements (Fe, Ni, Co, Cr, Mn, Zr, Cu…)and isotopes (restrictions : thermodynamic data/computer memory/run duration)

  6. PACTITER V3.0 – ITER TCWS DIV/LIM loop scheme L. Di Pace (2003), « Report on status of 2002 PACTITER validation of task », Review meeting on ITER TA81-01, Frascati, 30th Sept. 2003

  7. PACTITER V3.0 – input data

  8. PACTITER V3.0 - Simulation • Encouraging results • Raw calculation (without parameter optimization) • Results : same order of magnitude as V2.1

  9. PACTOLE V3.1  PACTITER V3.1 • Improvement of the chemistry module • New approach for oxide determination and equilibrium concentration calculation • Model based on a survey of oxides thermodynamic behavior • Implementation of the PHREEQC code and the « CEA thermodynamic database » ( Europe,to be confirmed) • Improvement of the corrosion/release mechanism • Based on empirical mathematical expression (parameters such as temperature, velocity, saturation…) • Treatment of oxidizing conditions  PACTITER V3.1 : reference version

  10. Development and validation requirements - Code • Implementation of Cu thermodynamic data in PHREEQC-CEA • Determination of a parametric expression for the corrosion and release rates (parameter such as temperature, velocity, saturation…) • Calculations to test the code – Preliminary validation

  11. Development and validation requirements - Experiments • Experiments must cover the range of the ITER conditions: • Chemical characteristics • Chemical conditioning (pH20°C=7.0, [H2]=25 cm3/kg, [Li]=0,2 ppm), • Corrosion product concentration (pure – saturated coolant) • Thermohydraulic characteristics • Fluid temperature (50°C  240°C) • Velocity (static water 12m/s) • Materials • Type of materials : stainless steel, copper alloy • Manufacturing process • Short and long-term experiments • Two types of experiments are requested: • Experiments to obtain input data in ITER conditions, • Semi-integral and integral experiments in ITER conditions to validate some particular physical models and the PACTITER code itself.

  12. PACTITER needs : data acquisition • Data acquisition for PACTITER V3 : • Complementary SS release rate at higher temperature (2005) • CuCrZr release rate (2006) • Literature survey • Semi integral CORELE tests

  13. PACTITER needs : validation • Validation of the deposition model of PACTITER V3 • Semi integral test loop representative of ITER PHTS • CIRENE feasibility study (2004) • Complementary feasibility study to assess the interest of CORELE and the Cu measurement methodology (2005)

  14. PACTITER needs : validation (continued) • Validation of the whole ACP transfer including release and deposition during an ITER scenario. • Towards an integral loop : • Adaptation of existing means ? • Creation of a new loop ? • Complementary feasibility study

  15. PACTITER needs (continued) • Planification of experiments required for compatibility with : • ITER licensing needs • PACTITER evolution • Financial considerations • Technological modifications of the loops

  16. PACTITER needs: proposal of planification

More Related