470 likes | 844 Vues
CIMON PLC. KDT Systems Co., Ltd. Why CIMON PLCs ?. All CPU share the same programming environment (CICON) No additional training needed for up/down sizing of control system Though BP series are small sized PLC, they inherit powerful functionalities from higher series of CIMON PLCs (CP/XP).
E N D
CIMON PLC KDT Systems Co., Ltd.
Why CIMON PLCs ? • All CPU share the same programming environment (CICON) • No additional training needed for up/down sizing of control system • Though BP series are small sized PLC, they inherit powerful functionalities from higher series of CIMON PLCs (CP/XP) KDT SYSTEMS
Why CIMON PLCs ? • CP and XP CPU share the same modules • I/O modules, special function modules, power, base .... • Provides big merit on maintenance as well as cost. KDT SYSTEMS
Why CIMON PLCs ? • Fully verified network compatibility • not only between PLCs • but also SCADA and Panels (TOUCH, XPanel) KDT SYSTEMS
What is different ? : Technologies • How many PLC manufacturers support redundant system in all around the world ? • CIMON supports redundant PLC CPU system. • and we have some good references as power plant. KDT SYSTEMS
Redundant CPU Details KDT SYSTEMS
What is different ? : Expansion • Innovative base expansion system • Provides easy engineering with simple cable • Removes the distance limit between bases • Plays the same role of remote I/O, but faster. • Expansible up to 16 bases Category 5, 10Base-T, Max 100m KDT SYSTEMS
Expansion numner setup byrotaryswitch LOCAL CPU EXPANSION #1 EP02A • 2 Port • 10Mbps Ethernet EXPANSION #2 EXPANSION #14 EP01A • 1 Port • 10Mbps Ethernet EXPANSION #15 EXPANSION #16 KDT SYSTEMS
What is different ? : Ethernet • Take the internet on your fields • Even BP supports the ethernet. (option) • Remote maintenance by internet : The CICON can connect with a PLC though internet. KDT SYSTEMS
What is different ? : CICON • Dialog based configuration • Removes DIP switches from special function modules • Dialog based programming • Generates sequence program automatically • PID, Protocol, Network configurations • Special function card configurations • Thermistor, Loadcell, position (pulse output) • Continued .... KDT SYSTEMS
Dialog based programming KDT SYSTEMS
CPU Specification : XP KDT SYSTEMS
CPU Specification : CP • CP3P : Removable flash memory KDT SYSTEMS
CPU Specification : BP KDT SYSTEMS
CPU Specification : BP BP32M • Abundant program capacity: • 8,000 Step • Device Range: • Internal Relay: 4,096 Points • Data Memory: 5,000 Words • Max. 3 block expansion BP16M • Abundant program capacity: • 4,000 Step • Device Range: • Internal Relay: 4,000 Points • Data Memory: 1,000 Words • Not expansible KDT SYSTEMS
Power • SPA cannot be used with analog/temperature modules KDT SYSTEMS
Base KDT SYSTEMS
Digital Input XD16A XD16B • 16 DC 24V Input • Photo coupler isolation XD32C XD32B • 32DC 24V Input • Photo coupler isolation XA08A XA08B • 8AC Input XY16DR • 8 24Vdc Input • 8 Relay Output KDT SYSTEMS
Digital Output YR16A • 16 Relay • 2 Amp / 240VAC YT16A YT16B • 16 Tr. Output • 0.5A / 24V • Sink /Source YS08A • 8SSR • 100~240Vac YT32A YT32B • 32Tr. Output • 0.2A / 24V • Sink /Source KDT SYSTEMS
Analog Input • All settings are configured by CICON • Input Voltage: 0 ~ 5V, 1 ~ 5V, 0 ~ 10V, -10 ~10V • Input Current : 0 ~ 20mA, 4 ~20mA • Resolution : 14 bit • Photocoupler isolated KDT SYSTEMS
Analog Output • All settings are configured by CICON • Output Voltage: -10 ~10V • Output Current : 4 ~20mA • Resolution : 14 bit • Photocoupler isolated. KDT SYSTEMS
RTD • 4Channels • All settings are configured by CICON • Resolution : 14 bit • Real temp. value provided (in C, F) • Resolution in Temp. : 0.1 C • Photo coupler isolated KDT SYSTEMS
Thermocoupler TC04A • 4Channels • All settings are configured by CICON • Resolution : 14 bit • Real temp. value provided (in C, F) • Resolution in Temp. : 0.1 C • Photo coupler isolated KDT SYSTEMS
Thermistor TH08A • 8 Channels • All settings are configured by CICON • includes resistance table input • Type : NTC thermistor • Resolution : 14 bit • Real temp. value provided (in C, F) • Resolution in resistance : • 100Ω ~ 40kΩ : 1Ω • 40kΩ ~ 400kΩ: 10Ω • 400kΩ ~ 1MΩ : 30Ω KDT SYSTEMS
Loadcell WG02A /WG04A • 2 or 4 channels loadcell input ( ~ 3mV/V) • 1/200,000 resolution • Embedded batch process control (unloading/mixing/filling/bin) KDT SYSTEMS
High Speed Counter • 2 Channels • All settings are configured by CICON • 1-Phase input or 2-Phase input • 32 bit counter • Speed : Max. 200 kPPS • Provides comparator output (<, =, >) KDT SYSTEMS
Pulse Output / Positioning PS02A • 2 axis • Line driver pulse output (RS422A) • All settings are configured by CICON • Position parameter / tables • Supports 2 axis linear/arc interpolation • Speed : Max. 1 MPPS KDT SYSTEMS
Serial Communication • Application Protocol • HMI-Protocol • MODBUS/RTU Slave & Master • DNP3.0 • PLC Link : Max. 32 stations • Loader (CICON) communication • Supports modem connection • Embedded RS232C-RS422/485 converter KDT SYSTEMS
Typical Serial Application Plays a role of RS232C-RS485 Converter KDT SYSTEMS
Remote Network by Modem Leased Line Modem (DSU) or Dial-Up Modem KDT SYSTEMS
Ethernet • No limit on number of EC01A with a CPU • Application Protocol • HMI-Protocol, MODBUS/TCP, DNP3.0 • PLC Link : Max. 64 stations • Loader (CICON) communication • Protocol Stack • ARP, ICMP, IP, UDP, TCP • 10BaseT, 10 Mbps KDT SYSTEMS
HMI Link by Ethernet KDT SYSTEMS
PLC Link by Ethernet KDT SYSTEMS
Data Logger LG32A / LG64A • Data log buffer for PLC • Logged data are retained in PLC while communication fail. • All logged data are transmitted to SCADA after communication recover. • Embedded communication • Protocol : HMI Protocol • Port : RS232C (supports cable / dial-up modem) • Internal non-volatile log memory: 32 MB / 64MB KDT SYSTEMS
Expansion block naming : BP CM2 – BP(1)E(2)(3) Series Name Output Type T: Digital TR Output(Sink) C: Digital TR Output(Src) R: Digital Relay Output A: Analog Output O: No Output Number of Points 04, 16, 32 Input Type D: Digital DC 24V Input A: Analog Input R: RTD Input T: TC Input O: No Input Module Type E : Expansion KDT SYSTEMS
Digital I/O Expansion KDT SYSTEMS
Analog Expansion Analog module can be expanded up to 2 modules. KDT SYSTEMS