1 / 24

phase-lead compensator design

phase-lead compensator design. 20loga. 10loga. 0 dB. -1/aT. -1/T. ω m. 0 O. Properties of phase-lead compensator. a>1. |G c | dB. |G c (jω m )| dB =10loga. Maximum phase contributed at ω m. Geometric mean of singularities. Φ m.  G c. Note that. |G c (jω m )| dB =10loga.

dyanh
Télécharger la présentation

phase-lead compensator design

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. phase-lead compensator design 10.3 Phase-Lead Compensation

  2. 20loga 10loga 0 dB -1/aT -1/T ωm 0O Properties of phase-lead compensator a>1 |Gc|dB |Gc(jωm)|dB=10loga Maximum phase contributed at ωm Geometric mean of singularities Φm Gc 10.3 Phase-Lead Compensation

  3. Note that |Gc(jωm)|dB=10loga 10.3 Phase-Lead Compensation

  4. ωg gain 0 dB phase 180o Amount to be contributed by Gc Desired PM ΦD Phase available (plant) ΦA 10.3 Phase-Lead Compensation

  5. ωg ω’g gain 0 dB ΦD phase 180o A naive idea Let Φm= ΦD -ΦA ωm= ωg Unavoidable! New PM ΦA Less than desired ? ! 10.3 Phase-Lead Compensation

  6. ωg gain 0 dB phase 180o Why? Gain crossover shifts to right ω’g ωg 1.Phase available from plant, less than ΦA 2.Phase available from compensator, less than Φm 10.3 Phase-Lead Compensation

  7. Measures to be taken • 1. Add some safety to Φm • usually about 5o 2. Choose ωm = ω’g ! How! 10.3 Phase-Lead Compensation

  8. ωg ω’g 10loga gain 0 dB -10loga phase 180o ω’g : frequency at which |GH|=-10loga Let ωm =ω’g Φm fully utilized! 10.3 Phase-Lead Compensation

  9. Procedure Specs: steady-state error & phase margin Determine the gain compensation for desired st.st. error 1 K Sketch Bode plot & determine phase margin for KGH 2 ΦA Safety 5o-10o 3 Φm Φm = ΦD - ΦA + ε 4 a 10.3 Phase-Lead Compensation

  10. Procedure cont’d 5 Find ωm = ω’g |KGH(jωm)|= -10loga ωm 6 T 7 Gc 10.3 Phase-Lead Compensation

  11. Final check 8 Sketch Bode plot for KGcGH & check results If not satisfactory, go back & modify (Increase safety??) 10.3 Phase-Lead Compensation

  12. Remarks Phase margin increased Improved relative stability  Smaller overshoot Gain crossover shifted to right ω’g ωg Larger band-width  More susceptible to noise  Faster 10.3 Phase-Lead Compensation

  13. Further remarks Fails if : Phase characteristics is too steep Drop in ΦAis large Gain characteristics is too flat Shift in ωg is large Drop in ΦAis large 10.3 Phase-Lead Compensation

  14. Example Specs: Steady-state error to unit ramp  10% PM > 30o 10.3 Phase-Lead Compensation

  15. Step 1 Earlier example: K=20 Satisfies the st.st. error requirement 10.3 Phase-Lead Compensation

  16. Bode Diagrams 60 40 20 0 Phase (deg); Magnitude (dB) -100 -120 -140 -160 -180 -1 0 10 10 Frequency (rad/sec) Step 2 Bode plot for Gm = Inf, Pm=13.669 deg. (at 4.5152 rad/sec) and PM. Yields PM=ΦA=13.669o at ωg=4.5 rad/sec. 10.3 Phase-Lead Compensation

  17. Steps 3&4 Φm = ΦD - ΦA + ε = 30o - 13.669o + ε = 16.331 + ε Φm = 21.331o Take safetyε=5o a=2.143 10.3 Phase-Lead Compensation

  18. 20 10 -3.31 dB 0 -10 Phase (deg); Magnitude (dB) -120 -140 -160 0 1 10 10 Frequency (rad/sec) Step 5 Determine the frequency at which |KGH|= -10loga = -10log2.143= -3.31 6.45 rad/s Yields 6.45 rad/sec ωm = 6.45 rad/sec 10.3 Phase-Lead Compensation

  19. Step 6&7 T 0.125 10.3 Phase-Lead Compensation

  20. Bode Diagrams Gm = Inf, Pm=32.473 deg. (at 5.4525 rad/sec) 60 40 20 0 -20 -40 Phase (deg); Magnitude (dB) -100 -120 -140 -160 -180 -1 0 1 10 10 10 Step 8 Bode plot of the compensated system Yields PM=32.47o 10.3 Phase-Lead Compensation

  21. Step Response Closed Loop Bode Diagrams 1.6 1.4 0 1.2 -20 1 -40 Amplitude Phase (deg); Magnitude (dB) 0.8 0 0.6 -50 0.4 -100 0.2 -150 0 0 1 2 3 4 5 -1 0 1 2 10 10 10 10 Time (sec.) Frequency (rad/sec) Overall check 10.3 Phase-Lead Compensation

  22. Evaluation of results Overshoot reduced 60  40% Settling time reduced 10  2 sec Rise-time reduced somewhat Resonance peek reduced 10.3 Phase-Lead Compensation

  23. Plant Uncompensated Compensator Compensated RL interpretation 10.3 Phase-Lead Compensation

  24. End of Section Next section Restart section Restart chapter i The End General index End show 10.3 Phase-Lead Compensation