1 / 6

SHIPTRAP: the Penning trap spectrometer at GSI Ana Martin

SHIPTRAP: the Penning trap spectrometer at GSI Ana Martin. stopping. cooling, accumulation. Gas. Cell. purification. measurement. Extraction. RFQ. Buncher. Measurement. Transfer section. Trap. Purification. Trap. Detector. SHIPTRAP = SHIP + TRAP + ….

eagan-oneil
Télécharger la présentation

SHIPTRAP: the Penning trap spectrometer at GSI Ana Martin

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SHIPTRAP: the Penning trap spectrometer at GSIAna Martin JINA 2007, Ana Martin

  2. stopping cooling, accumulation Gas Cell purification measurement Extraction RFQ Buncher Measurement Transfer section Trap Purification Trap Detector SHIPTRAP = SHIP + TRAP + … SHIPTRAP = Precision experiments with fusion-evaporation reaction products at low energy behind SHIP using ion traps target wheel beam dump primary beam, 3-4 Mev/u JINA 2007, Ana Martin

  3. Magnetron motion:E x B drift B Reduced cyclotron motion: Ф0 axial motion cyclotron motion magnetron motion Ion Motion in a Penning Trap Axial motion:oscillation in E-field JINA 2007, Ana Martin

  4. 185 mm 32 mm Pumping barrier 212 mm E Measurement Trap Diaphragm Purification Trap 111Te+ 600ms Double system Penning trap precision mass measurement via the determination of the ion cyclotron frequency TOF-ICR = Time-of-flight Ion Cyclotron Resonance buffer gas cooling mass selective (isobaric purification) JINA 2007, Ana Martin

  5. The Sn-Sb-Te cycle Mass measurements in the rp-process end point region 50Cr+58Ni→108Te* @ 3.6 MeV/u - 4.0 MeV/u 58Ni+58Ni→116Ba* @ 4.0 MeV/u 40Ca+58Ni→98Cd* @ 5.0 MeV/u Precision mass measurements are important for rp-process calculations JINA 2007, Ana Martin

  6. SHIPTRAP collaborators GSI / SHIPTRAP M. Block D. Beck M. Dworschak S. Eliseev F. Herfurth H.-J. Kluge A. Martín W. Quint C. Rauth G. Vorobjev GSI / SHIP D. Ackermann F. P. Heßberger S. Hofmann M. Mazzocco Mainz K. Blaum R. Ferrer J. Ketelaer C. Weber H. Backe P. Kunz W. Lauth Munich D. Habs J. Neumayr M. Sewtz P. Thirolf Greifswald A. Chaudhuri G. Marx L. Schweikhard Giessen M. Petrick C. Scheidenberger W.R. Plaß St. Petersburg Y. Novikov Veterans: D. Rodríguez, M. Mukherjee, S. Rahaman, ... JINA 2007, Ana Martin

More Related