1 / 108

Comfort II

Comfort II. Product Training. Revised February 2009. Objectives. Learn Comfort, benefits/features Learn to design Comfort system to suit customers requirements Learn how to install, connect Comfort and peripherals Learn how to program, test and commission Comfort. Equipment .

emily
Télécharger la présentation

Comfort II

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Comfort II Product Training Revised February 2009

  2. Objectives • Learn Comfort, benefits/features • Learn to design Comfort system to suit customers requirements • Learn how to install, connect Comfort and peripherals • Learn how to program, test and commission Comfort

  3. Equipment • Training Rig with; • Comfort CP9000 Controller • KP04 LCD keypad • DP03 Door Station+ Ringer • UCM05 • LEM01-M2 • SEM01 Slave Expansion Module • RC01 • Optional (Trainer Kit) • SCS • UCM/GSM • UCM/Cbus • CWM

  4. Handouts • Comfort Resources (Transfer via USB Drive) • Cytech Movie 2008 on DVD

  5. Agenda • Part I - Product Training • Comfort Demo Movie • Introduction to Cytech • Product Introduction and Demo • Key Features • Configuration and Modules • Part II Technical Training • Connections and Layout • Programming • Hands-on Programming Exercise • Testing and Commissioning • Questions

  6. About Cytech • Established in 1995 • Comfort I without keypad produced in 1996, telephone operated system • Keypad KP01 in 1999 • Sold in more than 20 countries • Cytech supplies through distributors and system integrators, does not install or sell to end users. • Cytech Europe – UK Master distributor • Staff of 10 (2008) – mainly in R&D and support. Manufacturing is subcontracted to contract manufacturers

  7. Introduction

  8. What is Comfort? An Intelligent Home System with; • Intruder Alarm System • burglary and fire • Digital answering machine • Home automation system • Controls lighting, HVAC and other home appliances • Telephone Voice Menu • Intercom – Door Station and Keypads • Reminder messages • Time Programs/ Scheduling

  9. Comfort Demonstration • Demonstration of Comfort using Training Rig (with GSM), • Security – arming, disarming, alarm dialout to phone/GSM • Home control Lighting and air conditioner • Door station intercom with keypad • RC01 remote control operation • SCS06 operation • SMS Control

  10. Key Features • Security System • Home Automation • Voicemail • Intercom • Time Programs • Integration • Logic Engine • NOT a plug and play system – requires integration

  11. Security System EN50131/PD6662 compliant (self declaration) Not necessary unless police response is required

  12. Security Modes • 5 Modes • Security Off, Away, Night, Day, Vacation. • Security Off • System disarmed, 24hrs zones still active • Away • Occupants are away • Night • Protects certain allocated zones when occupants are asleep • Day • Doors/windows protected by PIRs are inactive • Vacation • Same as Away but appliances can be switched on/off in a semi-random manner to create the impression of occupancy

  13. Security Zones • Up to 64 Zones of Security • Each zone is assigned a Zone Type to describe its properties, words to announce, and Response

  14. Security Types >Zone Types • 31 Preconfigured Zone Types can be assigned to each zone • Eg Door/Window, Entry Door, Fire, Panic • Determines behaviour in each mode, Alarm type

  15. Alarm Types • 31 programmable alarm types • Intruder, fire, smoke, gas, etc • Dial-out to combination of 8 phones • 20 siren types • Dedicated strobe output • Alarm response to trigger lights or announce message

  16. Comfort Dialer • Dials to 8 phone numbers • Combination of Voice phones, pager, CMS, SMS (with UCM/GSM) • Support 2 CMS numbers, standard formats • Each Alarm type can dial to any combination of 8 numbers • Alarm message • Voice message announces recorded alarm message and alarm type. • Allows access to Comfort • Listen to Alarm History or to disarm • Listen to sounds at home through keypads

  17. Security/Automation Linkage • Programmable Alarm Response • Eg Turn on all Lights on Intruder Alarm • Lighting up fire exit route and switching off air-conditioners during fire alarm • Lighting up areas in house when intruder alarm triggered in away mode to scare intruders

  18. Security/Automation Linkage • Each Zone has On and Off Response • Arming to Away, Night, Day has Response • Responses can have conditions, eg based on Time, If/Then, zone state, alarm state etc

  19. Security/Automation Linkage • Other possibilities: • Switching on the lights near the main door when opening the door at night • Switching off of lights and appliances upon arming to away mode • Triggering pre-recorded messages upon activation of perimeter motion detectors

  20. User Codes • 16 user codes • Answer machine mailboxes for first 8 • Programmable authorisation for each user • Sign-in tamper • 6 incorrect entries cause Sign-in Tamper • Duress alarm • When forced to disarm by intruder. User code +/- 2. Need two entries to confirm duress to avoid unintentional activation

  21. Engineer Menu • Engineer Sign In Option • Default code 6789 to enter Engineer Menu • F0 on keypad must be enabled by user to allow engineer code access • Allows programming via keypad or remote by telephone • Disabled after midnight to prevent unauthorized login • User may also disable it upon completion of programming

  22. Security Safeguards • Duress Code • Provides impression system is disarmed if forced to disarm • Sign In Tamper • Maximum of 6 unsuccessful attempts • Engineer Access Restriction • F0 required on Keypad to allow Engineer Programming • Cancels authorization when system is armed or after midnight each day

  23. Industrial Monitoring • Monitoring of Facilities (eg water, power, temperature, Equipment failure) • Call or SMS to maintenance when alarm triggered – alarms can call to any combinations of numbers • “English Industrial” wordlist available

  24. Home Automation

  25. Home Control Menu • Voice prompts on phone or keypad • Human Voice announcement, many languages available • No need to memorise activation codes • Announces status in menu

  26. Home Control Menu • Programmable into control groups (max 6) • Press 0 for Lights, 1 for Heating, 2 for Home Entertainment • Status feedback possible

  27. Home Control Menu • Quick Reference Card supplied with all Comfort systems

  28. Lighting Control • Control On/Off (not dimming) using TWS modules (lighting relay and current sensor) • Able to control X10 and PLCBus Modules • No specific Dimming module available. Comfort is not a lighting system • For dimming, use external lighting system eg EIB, C-Bus, Ulti, Dynalite, Lutron, X10, Zwave. Comfort does not tie installers or users to a specific lighting system • Comfort is sold by Schneider (some countries) as Minder Pro

  29. X10 Power Line Carrier • X10 two-way capability is built-in • Requires two-way X10 interface module (XM10E or equivalent) • Able to send and receive X10 commands to any X10 Address • X10 commands limited by responses • Received X10 codes can be used to trigger responses • Preset dim function supported • PLC Bus alternative to X10

  30. Clipsal C-Bus Lighting • Requires UCM/C-Bus • Able to use C-Touch to simulate Comfort keypad • Monitoring of zones, Comfort outputs • Control of C-Bus devices • ULTI RF switches can be controlled by UCM/ULTI

  31. KNX/European Installation Bus • Requires UCM/EIB • Able to control Comfort outputs via EIB switches • Control EIB/KNX devices

  32. Dynalite • Requires UCM/485 with RS485 interface • Control of Dynalite lights, scenes (one way, no status) • New Isolated RS485 interface available soon

  33. Ulti RF Switches • UCM/Ulti with antenna is required to control Ulti RF switches • 1 –way only, no status feedback

  34. ZWave RF System • Eg from Merten and ACT

  35. E-Home HDL Bus • RS485-bus based Dimmers, Switches, relays

  36. Other Lighting Options • Rako (RF Lighting) • Lutron • Others being developed

  37. Time Programs • 32 Time programs (Ultra System) • Activation on combination of days of week/holidays and a programmed time of day • User has option to enable/disable the time program • Trigger responses • Lighting control to switch off all lights, heaters, Air-cons • Arm or Disarm Security • Open or close curtains

  38. Responses/Scenes/Events • Comfort Ultra has 1024 Responses or programs that can be used for Scene Control, Time Programs, Zone Responses, Alarm Responses, Cbus/KNX responses, Scene Control Switch Responses etc • Events -> Responses is the key to Comfort’s power

  39. Sunrise/Sunset Responses • Sunrise and Sunset Times defined by City or Longitude/ Latitude • Automatic Daylight saving time change • Sunrise and Sunset Responses • Night Flag at night can be tested by Responses

  40. Reminders • 16 reminders (Ultra II) • scheduled to play at selected time • Combination of day of weeks and holidays • Enabled/disabled by users • Reminder Message is recorded by User • Reminders can also be played on door stations or keypads as warning messages triggered by events eg Motion Detector

  41. Voicemail

  42. Digital Storage • Comfort answers calls after programmed number of rings • User Greeting message is recorded to enable voicemail • Flash memory • Up to 10+ minutes of messages can be stored • Messages stored in non-volatile memory, maintained even during power failure

  43. Mailboxes • 8 personal user mailboxes • Users 9-16 do not have mailboxes • Name can be recorded • Callers can leave messages in the selected mailbox • Instead of individual mailboxes, common mailbox can be set up • Messages can be by callers or from other users • Can also forward to user’s mobile phone.

  44. Intercom

  45. Keypad • Able to intercom to any other keypads or doorstation • Keypads can be Baby Monitors

  46. KP04-SS • Stainless Steel Faceplate by B&S

  47. Door Station • Pressing Doorbell rings phones (RGR04 required) • Talk to visitor at door station using the internal phones • Dials to user in away mode allowing user to talk to the visitor • User able to control a gate or door to let visitor in DS01 DS02

  48. Configuration/Modules

  49. Control Panel CP9000 • 8 inputs and 8 outputs • Programmable zones (31 Zone types) • Outputs can be used to send pulse, IR signals, set On/Off • All I/O protected against voltage surges and overcurrent (resettable fuses) • Battery charger for 12V/7AH – monitors battery voltage

  50. I/O Expansion • Local Expansion – attached to Comfort or Slaves • Slave Expansion – Connected on Comfort RS485 bus • Remote Input/Output (RIO) – connected on Comfort RS485 bus