1 / 20

Rapid transition control of a CO 2 capture plant

Rapid transition control of a CO 2 capture plant. Håkon Dahl-Olsen and Sigurd Skogestad. Control philosophy. Skogestad and Postlethwaite (2005): Multivariable feedback control – analysis and design, Wiley. Maximum gain rule. Optimal control problem:. NCO:. Maximum gain rule.

fia
Télécharger la présentation

Rapid transition control of a CO 2 capture plant

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Rapid transition control of a CO2 capture plant Håkon Dahl-Olsen and Sigurd Skogestad

  2. Control philosophy Skogestad and Postlethwaite (2005): Multivariable feedback control – analysis and design, Wiley

  3. Maximum gain rule Optimal control problem: NCO:

  4. Maximum gain rule Hamiltonian Loss: A second-order approximation yields:

  5. P2P Gains – Simple • Look at step responses for the time-scale that is relevant for economic control:

  6. Cyclic operation of a CO2 removal plant

  7. Lean absorbent L Purified gas yCO2 ≤ 0.005 Column TC Sour gas feed Power plant Rich absorbent, LN 0.02 ≤yCO2 ≤ 0.06 CaCO3 (s), H2O, Ca(OH)2 (aq) PFD

  8. Modeling VLE described by Henry’s law for CO2/water system: Reaction in water phase: Assumed first-order kinetics:

  9. Modeling Variable definitions

  10. Optimal steady-state operation Minimize absorbent usage while maintaining y ≤ 0.5% (active)

  11. Optimal transition paths • Objectives: minimum time and limited absorbent usage • Constraint y < 0.5% at all times • This constraint is active for the transition phase • Constraint not measureable • Can measure dissolved CO2, but threshold on x = 5 ppm

  12. Optimal transition paths

  13. Implementation

  14. Scorecard 1: Direct measurement

  15. Can we use ratio control to limit the span of the CV? • Approximate span propagation by linearization

  16. Loss evaluation(Constant set point policy)

  17. Performance check CO2 comp. Absorbent feed Controlled variable

  18. Discussion