An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RinNOVA Cond XInovia CondInovia IN CIRCUITO COMANDO

  2. PANNELLO COMANDO DISPLAY LCD 70 mm X 50 mm DISPAY LCD 45 mm x 30 mm - TASTI TEMPERATURA SANITARIO TASTI TEMPERATURA SANITARIO - TASTI TEMPERATURA RISCALDAMENTO TASTI TEMPERATURA RISCALDAMENTO - SELETTORE STAGIONALE + ON/OFF SELETTORE STAGIONALE + ON/OFF + RESET - TASTO ATTIVAZIONE PRERISCALDO NON PRESENTE (combinazione di tasti) - TASTO MENU’ INFO NON PRESENTE (combinazione di tasti) – TASTO RESET TASTO RESET E ON/OFF MULTIFUNZIONE - M260 T PANNELLO COMANDI “TOP” M260 M / M261 M PANNELLO COMANDI “MEDIUM”

  3. INDICAZIONI DISPLAY TOP ATTESA RIACCENSIONE BRUCIATORE LIVELLO INTEGRAZIONE SOLARE INGRESSO MENU’ INFO SPAZZACAMINO ATTIVO RICHIESTA RISCALDAMENTO SCADENZA MANUTENZIONE PRERISCALDO ATTIVO; SE LAMPEGGIANTE PRERISCALDO IN ATTO REMOTO COLLEGATO; SE LAMPEGGIANTE RICHIESTA IN ATTO ANTIGELO PRESSIONE IN CALDAIA POMPA ALIMENTATA PRESENZA FIAMMA E LIVELLO DI MODULAZIONE TEMP. ESTERNA (SE COLLEGATA S.E.)

  4. INDICAZIONI DISPLAY MEDIUM PRESENZA FIAMMA SANITARIO ATTIVO; SE LAMPEGGIANTE RICHIESTA IN ATTO RICHIESTA INTERVENTO TECNICO RISCALDAMENTO ATTIVO; SE LAMPEGGIANTE RICHIESTA IN ATTO RICHIESTA SBLOCCO

  5. SCHEMA ELETTRICO RINNOVA COND X SCHEDA SIT 14064 1208

  6. SCHEMA ELETTRICO INOVIA IN SCHEDA SIT 14064 1208

  7. SCHEMA ELETTRICO INOVIA COND SCHEDA SIT 14064 1208

  8. COLLEGAMENTI ELETTRICI COLLEGAMENTI ELETTRICI ESTERNI ALLOGGIAMENTO SCHEDA COMANDO E CONNESSIONI ELETTRICHE ESTERNE

  9. COLLEGAMENTI ELETTRICI COLLEGAMENTI ELETTRICI ESTERNI AUSILIARI M260T / M261M M260T SCHEDA AUSILARE PER EVENTUALE VALVOLA DI ZONA M261M SCHEDA AUSILARE PER ELETTROVALVOLA DI RIEMPIMENTO

  10. SCHEDA COMANDO • FUNZIONI PARTICOLARI • GESTIONE VELOCITA’ POMPA; • GESTIONE VALVOLA DI ZONA • PRERISCALDO CON PROGRAMMAZIONE ORARIA • VISUALIZZAZIONE INFO SOLARE • SCADENZA MANUTENZIONE • SCHEDA INTEGRATA SIT 14064.1208.0 • FUNZIONI NORMALI • MODULAZIONE IN SANITARIO • MODULAZIONE RISCALDAMENTO • VERIFICA PRESSIONE DI CARICO (TRASDUTTORE DI PRESSIONE) • GESTIONE GUASTO SONDE • FUNZIONE ANTIGELO E 24 h • GESTIONE SONDA ESTERNA

  11. MODULAZIONE RISCALDAMENTO • COMPITO • PERMETTE DI MANTENERE COSTANTE LA TEMPERATURA IN MANDATA; LA VARIAZIONE DI POTENZA AL BRUCIATORE E’ DATA DAL VARIARE DEL NUMERO DI GIRI DEL VENTILATORE • CARATTERISTICHE • CONTROLLO DELLA TEMPERATURA ATTRAVERSO NTC PRIMARIO DI MANDATA • RAMPA DI SALITA FIAMMA: • NEI PRIMI 2 MINUTI DOPO LA RICHIESTA LA FIAMMA RIMANE SEMPRE AL MINIMO • IN QUESTO PERIODO VIENE VERIFICATO L’AUMENTO DELLA TEMPERATURA:SE L’AUMENTO E’ MINORE DI 5°C/MINUTO LA FIAMMA VIENE IMPOSTATA PER UN INCREMENTO DI 1° C OGNI 10 sec. (NTC DI MANDATA) • LA RAMPA DI SALITA SI INTERROMPE NON APPENA RAGGIUNTO IL VALORE IMPOSTATO/CALCOLATO • IL BRUCIATORE SI SPEGNE AL SUPERAMENTO DEL SET IMPOSTATO; • NEL TEMPO DI SPEGNIMENTO (P10) IL DISPLAY INDICA DISPLAY MEDIUM DISPLAY TOP

  12. MODULAZIONE RISCALDAMENTO CON SONDA ESTERNA • COMPITO • FAR LAVORARE L’IMPIANTO ALLA TEMPERATURA PIU’ INDICATA IN BASE ALLA TEMPERATURA ESTERNA, MIGLIORANDO IL RENDIMNETO DI CALDAIA ED IMPIANTO • CARATTERISTICHE • CONTROLLO DELLA TEMPERATURA ESTERNA TRAMITE SONDA ESTERNA • OBBLIGATORIO IMPOSTARE IL COEFFICIENTE K (P15) PER RELAZIONARE LA TEMPERATURA DI MANDATA CON LA TEMPERATURA ESTERNA IN BASE ALLA ZONA CLIMATICA ED AL TIPO DI IMPIANTO • PARAMETRI IMPOSTABILI • P15 E’ IMPOSTABILE DA 01 A 60: • (01 >>> K =0,1) • (60 >>> K =6,0) • P7 MANDATA MASSIMA (45-85°) • P27 MANDATA MINIMA (25-45°) • TRAMITE I TASTI SELEZIONE TEMP. MANDATA E’ POSSIBILE ALZARE O ABBASSARE LA CURVA DI 15°C P7 (45-85°) P27 (25-45°) Nel grafico in figura si vede l’effetto che ha l’impostazione dei parametri P15=2 P7=70 P27=35 sulla temperatura di mandata evidenziata in rosso

  13. MODULAZIONE SANITARIO COMPITO MANTENERE COSTANTE LA TEMPERATURA DI ACQUA CALDA SANITARIA IL CONFRONTO TRA LA TEMPERATURA LETTA DA NTC E SET IMPOSTATO PORTA ALLA VARIAZIONE DEL NUMERO DI GIRI DEL VENTILATORE CARATTERISTICHE DUE MODALITA’ DI FUNZIONAMENTO DISTINTE: P17=00 MODALITA’ MORMALE: AL RAGGIUNGIMENTO DEL SET SANITARIO IMPOSTATO IL BRUCIATORE SI PONE ALLA MINIMA POTENZA E RIMANE ACCESO FINO A TEMPERATURA ACS = 65° C P17=01 MODALITA’ ABBINAMENTO SOLARE: AL RAGGIUNGIMENTO DEL SET SANITARIO IMPOSTATO + 5°C IL BRUCIATORE SI SPEGNE (IDEALE PER ABBINAMENTO TRA CALDAIA ISTANTANEA E SISTEMA SOLARE A CIRCOLAZIONE NATURALE IN AMBO I CASI SE NTC R > 90° IL BRUCIATORE VIENE SPENTO ED IL DISPLAY INDICA L01 ESEMPIO DI ABBINAMENTO TRA SISTEMA SOLARE A CIRCOLAZIONE NATURALE E CALDAIA ISTANTANEA

  14. FUNZIONE PRERISCALDO 3 STELLE • COMPITO • DIMINUIRE IL CONSUMO D’ ACQUA SANITARIA MANTENENDO IN TEMPERATURA ILCIRCUITO PRIMARIO DELLA CALDAIA • CARATTERISTICHE • LA FUNZIONE SI ATTIVA PREMENDO IL TASTO APPOSITO • IL SET SANITARIO DEFINISCE LE TEMPERATURE ON ed OFF DELLA FUNZIONE (APPROSSIMATIVAMENTE COME IN FIGURA) • IL BRUCIATORE SI ACCENDE SE: • SE NTC R <PR ON (vedi grafico) • DOPO 55 MIN DALL’ULTIMA ACCENSIONE PER PRERISCALDO • IL BRUCIATORE SI SPEGNE QUANDO: • NTC R >PR OFF • DOPO 90 sec DALL’ACCENSIONE • DURANTE LA FUNZIONE PRERISCALDO IL BRUCIATORE RIMANE SEMPRE AL MINIMO • FUNZIONE ATTIVABILE ANCHE CON FASCE ORARIE TEMP. RISC. 85 PR OFF 80 75 70 SET SAN 65 60 55 PR ON 50 45 40 35 30 SET 25 ON 20 OFF 15 10 SET SAN. 5 0 40 45 50 55 60

  15. SISTEMA ANTIGELO • COMPITO • PROTEGGE LA CALDAIA IN CASO DI BASSE TEMPERATURE • DATI • ON 6 °C --- OFF 15° C • CONTROLLO TEMPERATURA ATTRAVERSO LA SONDA NTC R • IL BRUCIATORE VIENE ACCESO ALLA MINIMA POTENZA, VALVOLA TRE VIE IN SANIATRIO DISPLAY MEDIUM DISPLAY TOP FUNZIONE “VENTIQUATTRORE” • COMPITO • EVITA CHE IL CIRCOLATORE SI BLOCCHI NEL CASO LA CALDAIA RESTI INATTIVA PER LUNGHI PERIODI • DATI • ON QUANDO LA CALDAIA RESTA INATTIVA PER PIU’ DI 24 ORE • I CIRCOLATORI VENGONO ALIMENTATI PER 30 SECONDI

  16. GESTIONE GUASTO SONDE • GUASTO SONDE RISCALDAMENTO • ANOMALIA TRAMITE DISPLAY: E06 + (sonda mandata) • ANOMALIA TRAMITE DISPLAY: E12 + (sonda ritorno) • UN GUASTO ALLE SONDE RISCALDAMENTO IMPEDISCE QUALUNQUE ACCENSIONE DEL BRUCIATORE; • GUASTO SONDA SANITARIO • ANOMALIA TRAMITE DISPLAY: E07 + • UN GUASTO ALLA SONDA SANITARIA (CORTO CIRCUITO O INTERROTTA) NON IMPEDISCE NESSUNA FUNZIONE; • GUASTO SONDA ESTERNA • ANOMALIA TRAMITE DISPLAY: E08 + • UN GUASTO ALLA SONDA ESTERNA NON IMPEDISCE NESSUNA FUNZIONE MA E’ ESCLUSA LA FUNZIONE TEMPERATURA SCORREVOLE; • GUASTO SONDA FUMI • ANOMALIA TRAMITE DISPLAY: E09 + • UN GUASTO ALLA SONDA FUMI IMPEDISCE QUALUNQUE ACCENSIONE DEL BRUCIATORE;

  17. GESTIONE TRASDUTTORE DI PRESSIONE • COMPITO • VERIFICARE LA CORRETTA PRESSIONE DEL CIRCUITO PRIMARIO • CARATTERISTICHE • ALIMENTATO A 5 Vcc • IL VALORE DELLA PRESSIONE VIENE RICAVATO IN BASE ALLA CADUTA DI TENSIONE (COME NTC) • IN BASE ALLA PRESSIONE LETTA SI POSSONO AVERE 4 SITUAZIONI DIVERSE COME DA TABELLA

  18. VERIFICA CIRCOLAZIONE ACQUA • COMPITO • VERIFICARE LA SUFFICIENTE PORTATA D’ACQUA NELLO SCAMBIATORE PRIMARIO • CARATTERISTICHE • QUESTA VERIFCA VIENE ESEGUITA REGISTRANDO LA VARIAZIONE DI TEMPERATRA SUL NTC R • LIMITE MAX INCREMENTO = 4 °C AL SECONDO • SE QUESTO LIMITE VIENE SUPERATO: • INDICAZIONE DISPLAY E14 + • POMPA E BRUCIATORE SPENTI PER 1 min • TENTATIVO DI RIACCENSIONE DOPO 1 min

  19. GESTIONE CIRCOLATORE • COMPITO • GESTIRE L’ALIMENTAZIONE ALLA POMPA IN BASE ALLO STATO DELLA CALDAIA • DATI • E’ SEMPRE IL PRIMO COMPONENTE CHE VIENE ALIMENTATO A FRONTE DI UNA QUALUNQUE RICHIESTA • PUO’ ESSERE BLOCCATO DA: • SEGNALE DI PRESSIONE CALDAIA TROPPO BASSA • SCARSA CIRCOLAZIONE D’ACQUA (INCREMENTO TEMP SU NTC R > 4° C/sec) • POST CIRCOLAZIONE DIFFERENZIATA: • DOPO RICHIESTA SANITARIO: 30 sec (NON MODIFICABILE) • DOPO RICHIESTA RISCALDAMENTO: 1 min (DEFAULT) (MODIFICABILE : P11= 0 -- 0 sec; P11=99 -- 10 min) • GESTIONE VELOCITA’ (solo INOVIA COND M260T): • CON PARAMETRO P03=02 GESTIONE AUTOMATICA (DEFAULT): • RISCALDAMENTO E SANITARIO: VELOCITA’ MASSIMA • POST CIRCOLAZIONI, ANTIGELO E PRERISCALDO: VELOCITA’ MINIMA • CON PARAMETRO P03=00 SEMPRE MASSIMA VELOCITA’ • CON PARAMETRO P03=01 SEMPRE’ MINIMA VELOCITA’ DISPLAY MEDIUM

  20. CONTROLLO E GESTIONE VENTILATORE • COMPITO • VERIFICARE LA CORRETTA FUNZIONALITA’ DEL VENTILATORE • CARATTERISTICHE • LA SCHEDA INTEGRATA GENERA UN SEGNALE PWM IN BASE ALLA POTENZA TERMICA RICHIESTA; QUESTO SEGNALE CORRISPONDE AL “NUMERO DI GIRI RICHIESTO” • IL VENTILATORE SI “AUTOVERIFICA” E COMUNICA ALLA SCHEDA IL NUMERO DI GIRI EFFETTIVAMENTE EFFETTUATO (EFFETTO HALL) • SE IL NUMERO DI GIRI EFFETTUATO DIFFERISCE DA QUELLO RICHIESTO: • BRUCIATORE OFF • DISPLAY E05 + • VENTILATORE OFF • POST VENTILAZIONE: DOPO OGNI ACCENSIONE DEL BRUCIATORE IL VENTILATORE RESTA ALIMENTATO PER 30 sec ALIM. 220 V CA SEGNALE CONTROLLO NUMERO DI GIRI

  21. TENTATIVI MULTIPLI DI RIACCENSIONE • COMPITO: • FUNZIONE CHE PERMETTE DI RIPETERE AUTOMATICAMENTE FINO A 3 TENTATIVI DI RIACCENSIONE DEL BRUCIATORE • DATI: • SE PER UN QUALUNQUE MOTIVO IL BRUCIATORE NON RIESCE AD ACCENDERSI (MANCATA ACCENSIONE) LA SCHEDA RIPETE FINO 3 TENTATIVI RITARDATI DI 30 sec TEMPO NEL QUALE RIMANE ATTIVO IL VENTILATORE (FUNZIONE PULIZIA CAMERA DI COMBUSTIONE); • LA RILEVAZIONE FIAMMA NON E’ SENSIBILE ALL’INVERSIONE FASE-NEUTRO; • SE SBAGLIA ANCHE IL TERZO TENTATIVO INDICAZIONE DISPLAY: E01

  22. POTENZA UTILE RISCALDAMENTO • COMPITO • ADATTARE LA MASSIMA POTENZA DEL BRUCIATORE IN BASE ALLA DIMENSIONE DELL’IMPIANTO TERMICO SENZA VARIARE LA POTENZA MINIMA O LA POTENZA IN SANITARIO (ANCHE PER VERSIONE SV) • TRAMITE IL P12 E’ POSSIBILE SELEZIONARE LA POTENZA MASSIMA PIU’ INDICATA: IL CAMPO DI MODULAZIONE PUO’ VARIARE COME DA TEBELLA

  23. REGOLAZIONE DATA E ORA (solo INOVIA COND) SU QUESTA SCHEDA E’ POSSIBILE IMPOSTARE ORA E DATA CHE SERVONO SIA PER IMPOSTARE LE FASCE ORARIE DEL PRERISCALDO CHE PER LA FUNZIONE “SCADENA MANUTENZIONE” • IMPOSTAZIONE OROLOGIO • TENERE PREMUTO PER CIRCA 5 sec IL TASTOL • CON I TASTI A e B SI CAMBIA IL VALORE • CON IL TASTO L SI MEMORIZZA LA MODIFICA • CON I TASTI G e H SI PASSA DI PARAMETRO • CON IL TASTO L SI SALVANO LE MODIFICHE • TENENDO PREMUTO L PER 5 sec SI ESCE DALLA PROGRAMMAZIONE

  24. FASCIE ORARIE PRERISCALDO (solo INOVIA COND) • COMPITO • PROGRAMMARE LA FUNZIONE PRERISCALDO IN BASE ALLE REALI ESIGENZE DELL’UTENTE • IMPOSTAZIONE FASCIE ORARIE PRERISCALDO • TENERE PREMUTO PER 5 sec I TASTI L e H • IL DISPLAY INDICA P1ON (PRIMO ORARIO DI ATTIVAZIONE) • CON IL TASTO D SI ENTRA IN MODIFICA DI P1ON • CON I TASTI A e B SI IMPOSTA L’ORARIO DESIDERATO • CON IL TASTO L SI MEMORIZZA LA MODIFICA • CON IL TASTO H SI ESCE DALLA MODIFICA • CON I TASTI G e H SI AVANZA DI PARAMETRO • IL DISPLAY INDICA P01OF (TERMINE PRIMA FASCIA ORARIA) • RIPETERE LE OPERAZIONI DAL PUNTO 3 • LE FASCIE ORARIE NON UTILIZZATE IMPOSTARE A 00:00 • CON IL TASTO F ATTIVARE LA FUNZIONE PRERISCALDO SE TUTTO CORRETTO IL DISPLAY VISUALIZZA LE DUE ICONE EVIDENZIATE IN FIGURA

  25. INTEGRAZIONE SOLARE • COMPITO • METTERE IN COMUNICAZIONE CENTRALINA SOLARE E SCHEDA COMANDO CALDAIA PER VISUALIZZARE L’APPORTO DEL PANNELLO SOLARE • COLLEGAMENTO ELETTRICO ED INDICAZIONI DISPLAY CALDAIA • CENTRALINA SOLARE E CALDAIA COMUNICANO ATTRAVERSO LA LINEA COMANDO REMOTO (OT) • ATTRAVERSO APPOSITA ICONA SUL PANNELLO COMANDI CALDAIA VIENE INDICATO SIA IL COLLEGAMENTO CHE L’EFFETTIVA INTEGRAZIONE DISTINTA NEL CASO CHE CI SIA O MENO PRELIEVO REMOTO SIMBOLO PRESENTE:COLLEGAMENTO ATTIVO SIMBOLO LAMPEGGIANTE: POMPA SOLARE ATTIVA

  26. INTEGRAZIONE SOLARE • COLLEGAMENTO IDRAULICO ED INDICAZIONI DISPLAY • CALDAIA MISTA – COLLEGAMENTO SOLO CIRCUITO SANITARIO • CONSIGLIATA L’INSTALLAZIONE DI VALVOLA MISCELATRICE/DEVIATRICE CHE IN BASE ALLA TEMPERATURA DELL’ACQUA IN USCITA DAL BOLLITORE DEVIA O VERSO L’INGRESSO ACQUA FREDDA CALDAIA O DIRETTAMENTE ALL’UTENZA • LA CENTRALINA SOLARE COMUNICA IL VALORE DI S1 (vedi schema) ALLA CALDAIA CHE VISUALIZZERA’ IL LIVELLO DI INTEGRAZIONE COME DA TABELLA

  27. INTEGRAZIONE SOLARE • COLLEGAMENTO IDRAULICO ED INDICAZIONI DISPLAY • CALDAIA SV – COLLEGAMENTO SOLO CIRCUITO PRIMARIO • ATTRAVERSO LA LETTURA DELLA SONDA SB LA CALDAIA SI ATTIVA AUTONOMAMENTE PER INTEGRAZIONE BOLLITORE • LA CENTRALINA SOLARE COMUNICA IL VALORE DI S1 (vedi schema) ALLA CALDAIA CHE VISUALIZZERA’ IL LIVELLO DI TEMPERATURA DEL BOLLITORE COME DA TABELLA

  28. GESTIONE VALVOLA DI ZONA (solo INOVIA COND) • COMPITO • IL COMANDI REMOTO, A FRONTE DI UNA RICHIESTA DI CALORE DALL’AMBIENTE, PUO’ COMANDARE L’ACCENSIONE DELLA CALDAIA E L’APERTURA DI UNA VALVOLA DI ZONA • CARATTERISTICHE • FUNZIONE ATTIVABILE TRAMITE P04(default 00, non attiva) • SCHEDA AUSILIARE A RELE’ CON USCITA A 220 Vac • 3 CONTATTI: N (neutro) – NO (apertura) – NC (chiusura) • IN CASO DI IMPIANTO CON PIU’ VALVOLE DI ZONA COLLEGARE I LORO FINE CORSA SULLA LINEA TA (contatti 1 e 3 in morsettiera). IN QUESTO CASO LE TEMPERATURE DI MANDATA SONO DIVERSIFICABILI: ZONA REMOTO: SET DA REMOTO ZONE TA: SET DA PANNELLO COMANDI CALDAIA • IN CASO DI RICHIESTE CONTEMPORANEE LA TEMPERATURA DI MANDATA E’ IN FUNZIONE DI: P04 = 01 SET RISC. + ALTO • P04 = 02 SET RISC. + BASSO

  29. SCADENZA MANUTENZIONE • COMPITO • RICORDARE ALLL’UTENTE FINALE LA SCADENZA DELLA MANUTENZIONE. • INDICAZIONE DISPLAY • LA SEGNALAZIONE COMPARE 2 MESI PRIMA DELL’EFFETTIVA SCADENZA • LA SEGNALAZIONE NON IMPEDISCE ALCUNA FUNZIONE DELL’APPARECCHIO • IL RESET DEI MESI SI FA TRAMITE IL PM 28

  30. DIAGNOSTICA

  31. DISPLAY – MENU’ INFO • COMPITO • IL MENU’ INFO PERMETTE ESCLUSIVAMENTE LA LETTURA DEI “DATI DI SERVIZIO” DELLA CALDAIA DURANTE IL FUNZIONAMENTO. • UTILIZZO MENU’ INFO • PER ENTRARE NEL MENU’ INFO • TOP: PREMERE IL PULSANTE B FINO A CHE IL DISPLAY NON INDICA J00 + VALORE PARAMETRO • MEDIUM: PREMERE C + D FINO A CHE IL DISPLAY NON INDICA d0 + VALORE PARAMETRO • PER SCORRERE I PARAMETRI UTILIZZARE I TASTI C o D • PER USCIRE DAL MENU’ INFO PREMERE CONTEMPORANEAMENTE I TASTI A e D D D C C A B A

  32. DISPLAY – MENU INFO

  33. MENU’ HISTORY COMPITO LA MODALITA’ HISTORY PERMETTE LA VISUALIZZAZIONE GLI ULTIMI 10 ERRORI DATI PER ACCEDERE ALLA MODALITA’ “HISTORY” VEDI IMMAGINI SEGUENTI NEL DISPLAY COMPARIRA’ IL CODICE DELL’ERRORE ALTERNATO DAL NUMERO PROGRESSIVO DELL’ERRORE (H00+ E - - INDICA L’ULTIMO ERRORE REGISTRATO) IL PRIMO ERRORE CHE COMPARIRA’ E’ L’ULTIMO ACCADUTO. TRAMITE I TASTI DEL SANITARIO SI POSSONO SCORRERE GLI ULTIMI 10 ERRORI MEMORIZZATI.

  34. INOVIA COND : MENU’ PROGRAMMAZIONE • COMPITO • SETTARE LA SCHEDA DI RICAMBIO • ADATTARE LA CALDAIA AL TIPO DI IMPIANTO • SCHEDA DI RICAMBIO • APPENA INSTALLATA LA SCHEDA DI RICAMBIO VIENE SEGNALATO E99. TALE ERRORE SI RESETTA SOLO IMPOSTANDO IL PARAMETROP01 • INGRESSO MENU’ PROGRAMMAZIONE DA PANN. COMANDI • TENERE PREMUTO I PULSANTI A+B+D IN FIGURA (CIRCA 10 sec): IL DISPLAY INDICHERA’P01 CON IL RELATIVO VALORE IMPOSTATO • CON I TASTI A e B SI SCORRONO I VARI PARAMETRI • CON I TASTI H e G SI MODIFICANO I VALORI IMPOSTATI • CON IL TASTO D SI CONFERMA LA MODIFICA • TENERE PREMUTO I PULSANTI A+B+D PER USCIRE DALLA PROGRAMMAZIONE OPPURE TOGLIERE ALIMENTAZIONE ELETTRICA A+B+D A o B D H o G

  35. RINNOVA COND : MENU’ PROGRAMMAZIONE • COMPITO • SETTARE LA SCHEDA DI RICAMBIO • ADATTARE LA CALDAIA AL TIPO DI IMPIANTO • SCHEDA DI RICAMBIO • APPENA INSTALLATA LA SCHEDA DI RICAMBIO VIENE SEGNALTO E99. TALE ERRORE SI RESETTA SOLO IMPOSTANDO IL PARAMETROP01 • INGRESSO MENU’ PROGRAMMAZIONE DA PANN. COMANDI • TENERE PREMUTO I PULSANTI 15+16+17 PER CIRCA 10 sec, IL DISPLAY INDICHERA’ALTERNATIVAMENTE “P01” e “01” • PREMERE CONTEMPORANEAMENTE I TASTI 15 E 17 PER VEDERE IL VALORE DEL PARAMETRO; • MODIFICARE IL VALORE DEL PARAMETRO CON I TASTI 16 E 17; • CONFERMARE IL VALORE IMPOSTATO CON IL TASTO 15; • PER SCORRERE I VARI PARAMETRI UTILIZZAREI TASTI 16 E 17; • PER USCIRE PREMERE CONTEMPORANEAMENTE I TASTI 15, 16 E 17 OPPURE TOGLIERE ALIMENTAZIONE ELTTRICA

  36. SCHEDA INTEGRATA SIT : LISTA PARAMETRI

  37. SCHEDA INTEGRATA SIT : LISTA PARAMETRI

  38. SCHEDA INTEGRATA SIT : LISTA PARAMETRI

  39. SCHEDA INTEGRATA SIT : LISTA PARAMETRI

  40. SCHEDA INTEGRATA SIT : LISTA PARAMETRI

  41. SCHEDA INTEGRATA SIT : LISTA PARAMETRI

  42. SCHEDA INTEGRATA SIT : LISTA PARAMETRI

  43. SCHEDA INTEGRATA SIT : LISTA PARAMETRI