1 / 18

Simple benchmarks Final remarks on pion absorption

Simple benchmarks Final remarks on pion absorption. Witek Pokorski. Outline. short reminder on the setup validation/comparison plots conclusion. Pion absorption benchmark. (see talk given on 3 rd of March 2004 at the Physics Validation meeting)

gladys
Télécharger la présentation

Simple benchmarks Final remarks on pion absorption

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Simple benchmarks Final remarks on pion absorption Witek Pokorski Simulation Project

  2. Outline • short reminder on the setup • validation/comparison plots • conclusion Simulation Project

  3. Pion absorption benchmark • (see talk given on 3rd of March 2004 at the Physics Validation meeting) • general idea: thin target (Al,Cu,Au) experiment to study individual pion-nucleus process • experimental data • K. Nakai at al., PRL 44, 1446 (1980) • D. Ashery et al, PR C23, 2173 (1991) • simulation • G4 setup initially developed by Isidro Gonzalez (Alice) • ‘fake’ thin target experiment – large block of material, tracking stopped as soon as a process occurs • using QGSP_BERT physics list • Fluka ‘bypass’ provided by Alfredo Ferrari • using the new parametrisation based on the internal Fluka model Simulation Project

  4. Total inelastic cross section Simulation Project

  5. G4: Au cross section table corrected G4.6.1 G4.6.2 G4.6.2 G4.6.1 Simulation Project

  6. Absorptive part for pi+ Simulation Project

  7. Absorption Xsection for pi+ • both G4 and Fluka show reasonable agreement • in some cases Fluka seems to be a bit better • difficult to make more conclusions because of big uncertainties in the experimental data Simulation Project

  8. Absorptive part for pi- Simulation Project

  9. Absorption Xsection for pi- • same remarks as for pi+ • for heavy material (Au) the shape of the QGSP_BERT quite different (?) • G4: best agreement for ‘medium-weight’ materials Simulation Project

  10. Particle spectra for pi+ on Al Simulation Project

  11. Particle spectra for pi+ on Cu Simulation Project

  12. Particle spectra for pi+ on Au Simulation Project

  13. Particle spectra for pi- on Al Simulation Project

  14. Particle spectra for pi- on Cu Simulation Project

  15. Particle spectra for pi- on Au Simulation Project

  16. Summary • Both Geant4 and Fluka results show reasonable agreement between simulation and experimental data • In some cases Fluka seems to be a bit better than G4 with QGSP_BERT, but hard to judge because of big uncertainties in the experimental data • BUT: how well do we need to reproduce that data???? • bug corrected in G4 cross section tables • additional motivation for Fluka to move to the new parametrisation • LCG note on pion absorption benchmark in preparation Simulation Project

  17. Fluka parametrisations (1/2) Simulation Project

  18. Fluka parametrisation (2/2) Simulation Project