180 likes | 314 Vues
UNIT HEATERS. Clamshell Gas Fired Unit Heaters. GHND/GHPD. Propeller Type Fan Size 100 – 400 MBH 80% Thermal Efficiency Natural or LP Gas 10 Year Warranty on Heat Exchanger, Burners, and Flue Collector ODP Motors Standard, TE Optional Adjustable Power Venter Assembly
E N D
GHND/GHPD • Propeller Type Fan • Size 100 – 400 MBH • 80% Thermal Efficiency • Natural or LP Gas • 10 Year Warranty on Heat Exchanger, Burners, and Flue Collector • ODP Motors Standard, TE Optional • Adjustable Power Venter Assembly • Allows Greater Venting Flexibility. Can be rotated up to 90 Degrees in Each Direction. • Heavy Duty Fan Guard • OSHA Type Optional • Easy Access to High Limit Control and Pilot Access • All Controls are Accessible without Removing Side Jacket Panels
GBND/GBPD • Same Components as the GHND/GHPD Except the Propeller Assembly is Replaced with a Centrifugal Blower Assembly • Size 100 - 400 MBH • 80% Thermal Efficiency • Belt Guard is Standard • Double Blowers with Single Shaft Utilized on Units Size 300 - 400 MBH • 4 Point Suspension • Blower Allows Unit to Handle Greater Static • Lower Operating Noise
GAND/GAPD • Propeller Style Unit Heater Designed for Dusty, Dirty, Mildly Corrosive Environments and Areas of High Humidity and Slight Negative Pressures • Separates the Unit’s Combustion Process from the Environment in Which the Unit is Installed by Taking Combustion Air from Outside the Contaminated Space • Sizes Ranging from 100 - 400 MBH • 80% Thermal Efficiency • 1 Year Warranty on Heat Exchangers, Burners and Flue Collectors • Power Venter Assembly Draws in the Outside Combustion Air and Discharges Flue Gas • Hinged Bottom Door Allows for Complete Access to Burners and Controls
GKND/GKPD • Same Components as the GAND/GAPD Except the Propeller Assembly is Replaced with a Centrifugal Blower • Available in Sizes 100 - 400 MBH • 80% Thermal Efficiency • Belt Guard is Standard • 1 Year Warranty on Heat Exchanger, Burners and Flue Collector • Double Blowers with Single Shaft Utilized on Units Size 300 - 400 MBH • 4 Point Suspension • Blower allows unit to handle greater static • Lower Operating Noise
GLND/GLPD, option K or M • Side Access Burner Drawer • Sizes Ranging from 100 - 400 MBH • 30 - 80 ° F Temperature Rise • 80% Thermal Efficiency • 409 Stainless Steel Heat Exchanger Recommended when Installed Downstream of Cooling Coil • High Limit Accessible Through Side of Unit. Located Below 4x4 Junction Box • 1 Year Warranty on Heat Exchanger, Burners, and Draft Diverter
GLND/GLPD • Bottom Access Burner Drawer • 30 - 80 ° F Temperature Rise • 80% Efficient • Same Features as Side Access Models • Air Flow Baffle Required to Direct Air to the Bottom of Heat Exchanger Where the Highest Amount of Heat Transfer is Occurring • 1 Year Warranty on Heat Exchanger, Burners, and Draft Diverter • High Limit has Spring Loaded Assembly to Insure Contact with Heat Exchanger Header
GMND/GMPD • Same Components as the GAND/GAPD Except the Supply Air Fan is Removed from the Unit • Sizes Ranging from 100 to 400 MBH • 20 - 90 ° F Temperature Rise • 80% Thermal Efficiency. • 1 Year Warranty on Heat Exchanger, Burners, and Flue Collectors • 4 Point Suspension • Bottom Access Only to Burner Drawer
Tubular Gas Fired Unit Heaters Trane’s most versatile product line
GTND/GTPD – 30 to 120 MBH • ETL Certified for Residential Garage Installations • Sizes Ranging from 30 to 120 MBH • Low Profile Design Ideal for Low Clearance Installations • Over 82% Thermal Efficiency • Heavy Duty OSHA Fan Guard • Single Burner Design • LED Diagnostic Control Board • Open Drip Proof Motor Standard • 10 Year Heat Exchanger Warranty • Field Convertible to Separated Combustion • Gas Conversion Kit Included
GTND/GTPD – 150 to 400 MBH • Sizes from 150 to 400 MBH • 83% Thermal efficiency • Interior Baffles Aid in Heat Transfer and Increase Outlet Velocity for Increased Throw Delivery • Isolated Control Panel for Service Convenience • Multiple In-Shot Burner Design • Direct Spark Ignition • Thermostat wires to an exterior terminal strip located under the control cabinet access door for ease of installation • Tubular Heat Exchanger for Long Life. • 10 Year Heat Exchanger Warranty
UHSB – Header Type • (19) Sizes 18 - 360 MBH • OSHA Fan Guard Standard on 18 – 48 MBH = Residential Certified • Available for use with Steam or Hot Water • Coil Connections on Top and Bottom of Unit • Coil Constructed of Copper Tubes with Aluminum Fins • Factory Tested at 200 PSI • Totally Enclosed Fan Motor Standard, Explosion Proof Motor Optional • 1 Year Warranty
UHSBA – Serpentine • (4) Sizes 8 - 36 MBH • Hot Water Only • Coil Connections on Side of Unit • OSHA Fan Guard is Standard • Residential Certified • Coil Constructed of Copper Tubes with Aluminum Fins • Factory Tested at 200 PSI • Totally Enclosed Fan Motor Standard, Explosion Proof Motor Optional • 1 Year Warranty
UHPB • (15) Sizes 41-705 MBH • Available in Steam or Hot Water • Coil Connections on Top and Bottom of Unit • Copper Coil with Aluminum Fins Mechanically Bonded to the Tubes • Coils are Tested at 375 PSI • Threaded Steel Pipe Coil Connections • Totally Enclosed Fan Motor Standard, Explosion Proof Motor Optional • 1 Year Warranty