An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NiceMWDCA1710008County: LakeJar Test by Guy Schott, P.E. December 18-27, 2018

  2. Nice MWCSource Water: Clear LakeConventional Treatment

  3. Nice MWCSource Water: Clear Lake

  4. UVT/UVA • UV transmittance or UVT is a measurement of the amount of ultraviolet light (commonly at 254 nm due to its germicidal effect) that passes through a water sample compared to the amount of light that passes through a pure water sample. The measurement is expressed as a percentage, % UVT. • UVA – UV absorbance is calculated as a relative measure of the amount of light absorbed by a water sample compared with the amount of light absorbed by a pure water sample. • UVA = -log(%UVT/100)

  5. Coagulants Used for Jar Testing

  6. Laboratory Charge Analyzer LCA: Used to determine coagulant demand of a source water entering the treatment plant. Source pH: 7.93 - 8.05 pH adjusted to 7.5 w/acetic acid 9800: 27.3 - 30.5 mg/L as product 2) Source pH: 8.07 Added 2.2 mg/L of NaOCl pH adjusted to 7.5 w/acetic acid 9800: 31.8 mg/L as product 3) Source pH: 7.96 no pH adjustment 9800: 37 mg/L as product

  7. Nice MWC: Jar Test Results Coagulant dosages are reported as product.

  8. Nice MWC: Jar Test Results Coagulant dosages are reported as product.

  9. Jar Test Set 1

  10. End of 5 minute flocculation (30 RPM) period 2.2 mg/L NaOCl 30 mg/L 9800 Filtrate 0.05 NTU Settled: 1.2 NTU 2.2mg/L NaOCl 24 mg/L 9800 Filtrate 0.08 NTU Settled: 1.0 NTU 24 mg/L 9800 Filtrate 0.12 NTU Settled: 0.8 NTU 30 mg/L 9800 Filtrate 0.09 NTU Settled: 1.4 NTU

  11. 2.2mg/L NaOCl 24 mg/L 9800 Filtrate 0.08 NTU Settled: 1.0 NTU 2.2 mg/L NaOCl 30 mg/L 9800 Filtrate 0.05 NTU Settled: 1.2 NTU 24 mg/L 9800 Filtrate 0.12 NTU Settled: 0.8 NTU 30 mg/L 9800 Filtrate 0.09 NTU Settled: 1.4 NTU After 25 minute of setting, settled water turbidity is taken.

  12. Jar Test Set 2

  13. 2.2 mg/L NaOCl 40 mg/L 9800 Filtrate 0.06 NTU Settled: 0.5 NTU 2.2 mg/L NaOCl 45 mg/L 9800 Filtrate 0.06 NTU Settled: 0.9 NTU 2.2 mg/L NaOCl 30 mg/L 9800 Filtrate 0.09 NTU Settled: 0.4 NTU 2.2 mg/L NaOCl 35 mg/L 9800 Filtrate 0.06 NTU Settled: 0.4 NTU Towards end of 5 minute flocculation (30 RPM) period

  14. 2.2 mg/L NaOCl 45 mg/L 9800 Filtrate 0.06 NTU Settled: 0.9 NTU 2.2 mg/L NaOCl 40 mg/L 9800 Filtrate 0.06 NTU Settled: 0.5 NTU 2.2 mg/L NaOCl 35 mg/L 9800 Filtrate 0.06 NTU Settled: 0.4 NTU 2.2 mg/L NaOCl 30 mg/L 9800 Filtrate 0.09 NTU Settled: 0.4 NTU After 25 minute of setting, settled water turbidity is taken.

  15. Jar Test Set 3

  16. 2.5 mg/L NaOCl 43 mg/L 9800 Filtrate 0.05 NTU UVT: 90.9% UVA: 0.041/cm Settled: 0.20 NTU 2.5 mg/L NaOCl 37 mg/L 9800 Filtrate 0.05 NTU UVT: 90.7% UVA: 0.042/cm Settled: 0.60 NTU 2.5 mg/L NaOCl 50 mg/L 9800 Filtrate 0.05 NTU UVT: 91.2% UVA: 0.040/cm Settled: 0.60 NTU 2.5 mg/L NaOCl 30 mg/L 9800 Filtrate 0.08 NTU UVT: 90.3% UVA: 0.044/cm Settled: 0.20 NTU Towards end of 5 minute flocculation (30 RPM) period

  17. 2.5 mg/L NaOCl 50 mg/L 9800 Filtrate 0.05 NTU UVT: 91.2% UVA: 0.040/cm Settled: 0.60 NTU 2.5 mg/L NaOCl 43 mg/L 9800 Filtrate 0.05 NTU UVT: 90.9% UVA: 0.041/cm Settled: 0.20 NTU 2.5 mg/L NaOCl 37 mg/L 9800 Filtrate 0.05 NTU UVT: 90.7% UVA: 0.042/cm Settled: 0.60 NTU 2.5 mg/L NaOCl 30 mg/L 9800 Filtrate 0.08 NTU UVT: 90.3% UVA: 0.044/cm Settled: 0.20 NTU After 25 minute of setting, settled water turbidity is taken.

  18. Jar Test Set 4

  19. Towards end of 5 minute flocculation (30 RPM) period 2.5 mg/L NaOCl 30 mg/L 9800 4.5 mg/L 9890 Filtrate 0.07 NTU UVT: 90.8% UVA: 0.042/cm Settled: 0.28 NTU 2.5 mg/L NaOCl 37 mg/L 9800 5.6 mg/L 9890 Filtrate 0.06 NTU UVT: 90.9% UVA: 0.041/cm Settled: 0.26 NTU 2.5 mg/L NaOCl 43 mg/L 9800 6.4 mg/L 9890 Filtrate 0.07 NTU UVT: 91.0% UVA: 0.041/cm Settled: 0.30 NTU 2.5 mg/L NaOCl 50 mg/L 9800 7.5 mg/L 9890 Filtrate 0.05 NTU UVT: 91.3% UVA: 0.040/cm Settled: 0.40 NTU

  20. 2.5 mg/L NaOCl 30 mg/L 9800 4.5 mg/L 9890 Filtrate 0.07 NTU UVT: 90.8% UVA: 0.042/cm Settled: 0.28 NTU 2.5 mg/L NaOCl 37 mg/L 9800 5.6 mg/L 9890 Filtrate 0.06 NTU UVT: 90.9% UVA: 0.041/cm Settled: 0.26 NTU 2.5 mg/L NaOCl 43 mg/L 9800 6.4 mg/L 9890 Filtrate 0.07 NTU UVT: 91.0% UVA: 0.041/cm Settled: 0.30 NTU 2.5 mg/L NaOCl 50 mg/L 9800 7.5 mg/L 9890 Filtrate 0.05 NTU UVT: 91.3% UVA: 0.040/cm Settled: 0.40 NTU After 25 minute of setting, settled water turbidity is taken.

  21. Jar Testing – Procedures • Fill jars with source water prior to coagulant injection and set paddle speed at 30 rpm • Add chemicals (i.e., NaOCl, primary coagulant, coagulant aid) to each jar • Flash mix for 1 minute (200 rpm for 1 liter jars; up to 300 rpm for 2 liter jars) • Slow mix for 5 minutes (30 rpm for 1 liter jars, up to 40 rpm for 2 liter jars) • Settled for 5 minutes • Syringe 25 mL from each jar taken ½-inch below surface (25 mL/12 sec rate) • Filtered through 1.2 um isopore membrane into cuvette (drip rate, 15 mL/90 sec) • Measure filtrate turbidity, chlorine residual and %UVT or UVA • Measure settled water turbidity after 25 minutes of total setting • Record all data

  22. Jar TestFilterability Test Equipment Turbidity Instrument Syringe w/Luer-Lock Tip, 30 cc (part#: 2225800, by Hach) Swinnex Filter Holder, 25 mm (part#: SX0002500) Isopore Membrane Filter, 1.2 um, 25 mm (part #: RTTP02500) http://www.sigmaaldrich.com/

  23. Jar Test - Filterability Test Syringe ~ 25 mL from jar (after 5 minutes of settling) Filter-to-waste 3-5 mL Filter directly into clean cuvette Measure turbidity Note: Take several readings before recording final NTU results. Micro bubbles can adhered to glass causing false NTU readings. To remove bubbles, tilt cuvette up to 90 degrees.