1 / 3

IS-41 signaling line

Merit of elimination of the circuits controlled by IS-41. At present, IS-41 is controlling circuits inter MSC at the time of intersystem handoff. Therefore, the circuits which are controlled by ISUP and the circuits which are controlled by IS-41 are needed separately.

gypsy
Télécharger la présentation

IS-41 signaling line

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Merit of elimination of the circuits controlled by IS-41 At present, IS-41 is controlling circuits inter MSC at the time of intersystem handoff. Therefore, the circuits which are controlled by ISUP and the circuits which are controlled by IS-41 are needed separately. If ISUP can control the circuits inter MSC at the time of intersystem handoff, it becomes only the circuits which are controlled by ISUP among MSC. As a result, the number of the circuits among MSC can be decreased. Circuit cost also will decrease. IS-41 signaling line } X lines Circuits controlled by IS-41 (e.g. used for handoff) } ISUP signaling line Y lines Circuits controlled by ISUP (e.g. used for intersystem termination) IS-41 signaling line ISUP signaling line } Z lines Circuits controlled by ISUP (e.g. used for handoff and intersystem termination) Z < X + Y 1

  2. Assuming general call flow Serving MSC Target MSC HANDMREQ handmreq FACDIR2 Circuit related function of FACDIR2 will be eliminated. Circuits will be controlled by ISUP. facdir2 IAM ACM AMN MSONCH 2

  3. Conclusion At present, IS-41 is controlling circuits inter MSC at the time of intersystem handoff. Therefore, the circuits which are controlled by ISUP and the circuits which are controlled by IS-41 are needed separately. If ISUP can control the circuits inter MSC at the time of intersystem handoff, it becomes only the circuits which are controlled by ISUP among MSC. As a result, the number of the circuits among MSC can be decreased. Circuit cost also will decrease. I propose to start the process of standardization of elimination of the circuits controlled by IS-41. 3

More Related