1 / 8

Preliminary Results for T5, T6, T7, and T8

Preliminary Results for T5, T6, T7, and T8. Emmanuel Angulo (CSU Fresno). Gas Gain for T5-T8. T5 Uniformity. Connector 2. Connector 1. Connector 1. Middle point 4cm x 5cm. Corner points 1cm x 1cm. Connector 2. Connector 1. T6 Uniformity. Connector 2. Connector 2. Connector 1.

hachi
Télécharger la présentation

Preliminary Results for T5, T6, T7, and T8

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Preliminary Results for T5, T6, T7, and T8 Emmanuel Angulo (CSU Fresno)

  2. Gas Gain for T5-T8

  3. T5 Uniformity Connector 2 Connector 1 Connector 1 Middle point 4cm x 5cm Corner points 1cm x 1cm Connector 2 Connector 1

  4. T6 Uniformity Connector 2 Connector 2 Connector 1 Connector 2 Middle point 6cm x 5cm Corner points 1cm x 1cm Connector 2 Connector 1 Noise up to Ch 140 for connector 2 (This chamber was damaged at a pillar and George fixed it)

  5. T7 Uniformity Connector 2 Connector 1 Connector 1 Middle point 4cm x 5cm Corner points 1cm x 1cm Connector 2 Connector 1

  6. T8 Uniformity Connector 2 Connector 1 Connector 1 Middle point 4cm x 5cm Noise up to Ch 143 (Bad signal with connector 2) Corner points 1cm x 1cm Connector 2 Connector 1

  7. Charge Up Note: There is approximately a 5 second delay in between data points

  8. Conclusion • Gas Gain is good for all chambers • T5 and T7 have good spectrums and are fairly uniform • T6 seems to have a problem with connector 2 (strips 129 to 256), needs more testing • T8 has a bad middle region, needs more testing • The high charge up is consistent for the chambers with a ground mesh but only for the first 140 seconds (+ 45 seconds)

More Related