1 / 13

Reliable HICUM implementation in Eldo

Reliable HICUM implementation in Eldo. Mohamed Selim Device Modeling Team Mentor Graphics. HICUM Workshop, June . 2004. Overview. HICUM status in Eldo. Stability issues in the standard model. Enhancements done to improve stability. Current work done. Conclusion. Status.

hansel
Télécharger la présentation

Reliable HICUM implementation in Eldo

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Reliable HICUM implementation in Eldo Mohamed Selim Device Modeling Team Mentor Graphics HICUM Workshop, June . 2004

  2. Overview • HICUM status in Eldo. • Stability issues in the standard model. • Enhancements done to improve stability. • Current work done. • Conclusion. HICUM in Eldo, June 2004

  3. Status • Model implemented since 1999 in Eldo v5.3_1.1. • The model accuracy was reviewed versus DEVICE simulator and some major accuracy issues had been resolved in Eldo v5.8_1.1, released 2001. • In the 2001 workshop, ST presented a comparison between different commercial simulators showing that Eldo had the best implementation of the model for the DC results . • Since then, no modifications were done in the standard model, hence in Eldo just minor bug fixes were done. HICUM in Eldo, June 2004

  4. Stability Issues • Currents, Charges and their derivatives (conductances and capacitances) are needed from model for proper simulation for all types of analysis; DC, AC and TRANSIENT. • Convergence problems were seen using the standard model implemented in Eldo due to missing or incorrect derivatives (from the numerical point of view). • The standard model focuses on DC and small signal behavior mainly, many derivatives were not taken into account. HICUM in Eldo, June 2004

  5. Stability Issues • 4 Major points of instability exist: • Self heating derivatives. • Diffusion capacitance modeling. • NQS model. • RBI dependencies. • Some modifications in the existing derivatives were done and some derivatives were added to the standard model in Eldo to enhance the stability. • In the following slide a summary of the work done will be presented. HICUM in Eldo, June 2004

  6. Enhancements • Diode junction currents derivatives w.r.t. self heating (thermal) voltage. • Avalanche current derivative w.r.t. self heating (thermal) voltage. • RBI derivatives w.r.t. VBE and VCE. • Changing the expression for CDCI calculation. • Adding the new derivative of QDEI w.r.t. VCEI. • Applying the NQS effect on all derivatives of ITF (forward transfer current) and QDEI (base emitter depletion charge). HICUM in Eldo, June 2004

  7. Enhancements • These added features are added in AMS2004.2 release corresponding to Eldo v6.3_2.1. • A new parameter called AMSVER is added. • It can take 2 values. • 2004.1 -> Standard AC results are maintained. • 2004.2 -> AC results are changed (default). • For both values of AMSVER, the newly added derivatives are always used used to enhance convergence for DC and TRANSIENT analysis. HICUM in Eldo, June 2004

  8. Temp = 27 FREQ = 10MHz, 100MHz, 1 GHz, 10 GHz 1e12H 0.5v DC I2 1e12H 1.0v DC 0.01F V1 = 1mv AC 0.01F AC setup Enhancements HICUM in Eldo, June 2004

  9. Temp = 27 FREQ = 10MHz, 100MHz, 1 GHz, 10 GHz 1e12H 0.5v DC I2 1e12H 1.0v DC 0.01F V1 = sinusoidal source with peak value 1mv , frequency = FREQ 0.01F TRANSIENT setup Enhancements HICUM in Eldo, June 2004

  10. Enhancements • From the results the AC values with AMSVER = 2004.2 match those obtained from the TRANSIENT analysis and they are both different from the standard AC results with AMSVER = 2004.1. • All the testcases that showed convergence problems are working fine with the new modifications. HICUM in Eldo, June 2004

  11. Current Work • We are currently enhancing the speed of the HICUM model in Eldo. • This will be available in the AMS 2004.3 release. HICUM in Eldo, June 2004

  12. Conclusion • AMS 2004.2 (Eldo v6.3_2.1) which was released few weeks ago has a fully stable HICUM model with NO convergence issues. • AMS 2004.3 (Eldo v6.4_1.1) planned to be released by the end of the year will have the speed enhanced version of the model. • MG is always looking to keep the models in the very best shape from both accuracy compared to standard models point of view and model speed. HICUM in Eldo, June 2004

  13. HICUM in Eldo, June 2004

More Related