An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ICMS CONVEYOR Control

  2. Features • ICMS - Integrated signal line Control and Monitoring System which may include the trip wire or pullwire. • Dual stop/start circuits and time controlled sequencing of other conveyors or equipment. • BK400 and signal line system certified to AS1755-2000 compliance. • Monitored Pre-Start Warning modules at each BK400 along the complete system. • Remote Isolation Request from any BK400 station along the system. • Local Isolation Status indication from any BK400. • The ICMS monitoring system is DIGITAL employing an RS485 Brambus operating at 9600 Baud.

  3. Features • Power for the ICMS signal line system is derived from the Starter, Intermediate drive and EOL Box locations through the single 6 core cable at 24VDC. • PSW system is separately powered from same above locations at 48VDC. • ICMS Multinodes have multiple Trip inputs, inbuilt Data repeater function with switch selection. • Sequence A, B, C, D nodes provide interlocking between remote Brambus system locations. • Isolated RS485 Modbus ASCII port for PLC monitoring of system. • Safety Catagory Cat 4 System Integrity Level 5 (equiv SIL 3) for ICMS with SLC2.

  4. Pullwire Switch – BK400S

  5. Pre-Start Warning Unit PSW400

  6. Connection of Pre-Start Warning to Pullwire Switch PSW POWER CABLE 48VDC PSW POWER CABLE 48VDC PSW CONTROL CABLE BRAMBUS SIGNAL LINE CABLE BRAMBUS SIGNAL LINE CABLE

  7. The ICMS Conveyor Control & Monitoring System is a powerful and flexible solution for long conveyor applications. All faults and warnings on the system are displayed on the local screen and available via the serial port.