1 / 6

SAM: hardware options

SAM: hardware options. Explained in the Gen II spec updated for clarity in May 05 see Section 10.3 see Figure 10. http://www.cpac.washington.edu/NeSSI/NeSSI_Gen_II_Spec_6_21_04.pdf. Figure 10. Stand-alone SAM Embedded SAM. Stand-alone SAM.

heier
Télécharger la présentation

SAM: hardware options

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SAM: hardware options Explained in the Gen II spec • updated for clarity in May 05 • see Section 10.3 • see Figure 10 http://www.cpac.washington.edu/NeSSI/NeSSI_Gen_II_Spec_6_21_04.pdf

  2. Figure 10 Stand-alone SAM Embedded SAM

  3. Stand-alone SAM • SAM has its own enclosure • The NeSSI-bus provides intrinsically safe, bi-directional communication with sensors and actuators • Heating for the substrate, enclosure or other devices is controlled by SAM • SAM communicates to the DCS and operations and maintenance domains via Ethernet.

  4. Embedded SAM • The sensor or analyzer has its own controller and is directly connected to the controller, for example: • pH sensor connected with electrode cable • spectrometer with a sample cell on the substrate connected by fiber optic cable • GC with the sample delivered by NeSSI • SAM is embedded into the analyzer controller • The NeSSI-bus provides intrinsically safe, bi-directional communication with sensors and actuators • Heating for the substrate, enclosure or other devices is controlled by SAM • Analyzer controller communicates to the DCS and operations and maintenance domains via Ethernet.

  5. Legacy connectivity

  6. A way forward to develop SAM? • Start off with embedded systems in GCs • hardware (computing power) already there • networking to DCS/maint. domains already there • control of sample systems already part of design • Opportunity to develop and test functionality in fastest time and at lowest cost • Starts out with a natural deployment mechanism • Follow on by deploying the software into a stand-alone package • what ready made devices are already available?

More Related