An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Investigation on the mechanism responsible for degradation on Cu/Kapton foils Andy Wu

  2. The degraded Foil

  3. SEM Images of Spot A

  4. SEM Image of Part of Spot B

  5. EDX Observations at 25kV (A) Typical Spectrum for Spots A and B

  6. Typical EDX Spectrum at 25kV (open window) Typical Open Window Spectrum for Spots A&B

  7. Typical EDX Spectrum at 10 KV (surface) Typical Open Window Spectrum at 10 kV for Spots A&B

  8. Conclusion • The surfaces of the degraded spots are covered by a thin layer of copper oxides. The thickness of the layer is much below 1 μm.

  9. Composition of Granite SiO 72.04%, Al2O3 14.42%, K2O 4.12%, Na2O 3.69%, CaO 1.82%, FeO 1.68%, Fe2O3 1.22%, MgO 0.71%, TiO2 0.30%, P2O5 0.12%, MnO 0.05%

  10. Possible degradation mechanism • Evaporation of the DI water used to mediate the contact between Cu/Kapton foil and granite leads to several highly localized small area where active oxygen can reach certain level to be reactive to Cu. The active oxygen can come either from granite or possible residues from the manufacturer as one can see that the surface of the as received foil has discolored spots.

  11. Recommended Remedy • Seal the granite table to prevent the formation of some localized water spots. • Ask the manufacturer to do a better job on cleaning the Cu/Kapton foils